Cargando…

Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams

Foam sclerotherapy is clinically employed to treat varicose veins. It involves intravenous injection of foamed surfactant agents causing endothelial wall damage and vessel shrinkage, leading to subsequent neovascularization. Foam production methods used clinically include manual techniques, such as...

Descripción completa

Detalles Bibliográficos
Autores principales: Bottaro, Elisabetta, Paterson, Jemma, Zhang, Xunli, Hill, Martyn, Patel, Venisha A., Jones, Stephen A., Lewis, Andrew L., Millar, Timothy M., Carugo, Dario
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536569/
https://www.ncbi.nlm.nih.gov/pubmed/31165068
http://dx.doi.org/10.3389/fbioe.2019.00109
_version_ 1783421777177739264
author Bottaro, Elisabetta
Paterson, Jemma
Zhang, Xunli
Hill, Martyn
Patel, Venisha A.
Jones, Stephen A.
Lewis, Andrew L.
Millar, Timothy M.
Carugo, Dario
author_facet Bottaro, Elisabetta
Paterson, Jemma
Zhang, Xunli
Hill, Martyn
Patel, Venisha A.
Jones, Stephen A.
Lewis, Andrew L.
Millar, Timothy M.
Carugo, Dario
author_sort Bottaro, Elisabetta
collection PubMed
description Foam sclerotherapy is clinically employed to treat varicose veins. It involves intravenous injection of foamed surfactant agents causing endothelial wall damage and vessel shrinkage, leading to subsequent neovascularization. Foam production methods used clinically include manual techniques, such as the Double Syringe System (DSS) and Tessari (TSS) methods. Pre-clinical in-vitro studies are conducted to characterize the performance of sclerosing agents; however, the experimental models used often do not replicate physiologically relevant physical and biological conditions. In this study, physical vein models (PVMs) were developed and employed for the first time to characterize the flow behavior of sclerosing foams. PVMs were fabricated in polydimethylsiloxane (PDMS) by replica molding, and were designed to mimic qualitative geometrical characteristics of veins. Foam behavior was investigated as a function of different physical variables, namely (i) geometry of the vein model (i.e., physiological vs. varicose vein), (ii) foam production technique, and (iii) flow rate of a blood surrogate. The experimental set-up consisted of a PVM positioned on an inclined platform, a syringe pump to control the flow rate of a blood substitute, and a pressure transducer. The static pressure of the blood surrogate at the PVM inlet was measured upon foam administration. The recorded pressure-time curves were analyzed to quantify metrics of foam behavior, with a particular focus on foam expansion and degradation dynamics. Results showed that DSS and TSS foams had similar expansion rate in the physiological PVM, whilst DSS foam had lower expansion rate in the varicose PVM compared to TSS foam. The degradation rate of DSS foam was lower than TSS foam, in both model architectures. Moreover, the background flow rate had a significant effect on foam behavior, enhancing foam displacement rate in both types of PVM.
format Online
Article
Text
id pubmed-6536569
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-65365692019-06-04 Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams Bottaro, Elisabetta Paterson, Jemma Zhang, Xunli Hill, Martyn Patel, Venisha A. Jones, Stephen A. Lewis, Andrew L. Millar, Timothy M. Carugo, Dario Front Bioeng Biotechnol Bioengineering and Biotechnology Foam sclerotherapy is clinically employed to treat varicose veins. It involves intravenous injection of foamed surfactant agents causing endothelial wall damage and vessel shrinkage, leading to subsequent neovascularization. Foam production methods used clinically include manual techniques, such as the Double Syringe System (DSS) and Tessari (TSS) methods. Pre-clinical in-vitro studies are conducted to characterize the performance of sclerosing agents; however, the experimental models used often do not replicate physiologically relevant physical and biological conditions. In this study, physical vein models (PVMs) were developed and employed for the first time to characterize the flow behavior of sclerosing foams. PVMs were fabricated in polydimethylsiloxane (PDMS) by replica molding, and were designed to mimic qualitative geometrical characteristics of veins. Foam behavior was investigated as a function of different physical variables, namely (i) geometry of the vein model (i.e., physiological vs. varicose vein), (ii) foam production technique, and (iii) flow rate of a blood surrogate. The experimental set-up consisted of a PVM positioned on an inclined platform, a syringe pump to control the flow rate of a blood substitute, and a pressure transducer. The static pressure of the blood surrogate at the PVM inlet was measured upon foam administration. The recorded pressure-time curves were analyzed to quantify metrics of foam behavior, with a particular focus on foam expansion and degradation dynamics. Results showed that DSS and TSS foams had similar expansion rate in the physiological PVM, whilst DSS foam had lower expansion rate in the varicose PVM compared to TSS foam. The degradation rate of DSS foam was lower than TSS foam, in both model architectures. Moreover, the background flow rate had a significant effect on foam behavior, enhancing foam displacement rate in both types of PVM. Frontiers Media S.A. 2019-05-21 /pmc/articles/PMC6536569/ /pubmed/31165068 http://dx.doi.org/10.3389/fbioe.2019.00109 Text en Copyright © 2019 Bottaro, Paterson, Zhang, Hill, Patel, Jones, Lewis, Millar and Carugo. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Bottaro, Elisabetta
Paterson, Jemma
Zhang, Xunli
Hill, Martyn
Patel, Venisha A.
Jones, Stephen A.
Lewis, Andrew L.
Millar, Timothy M.
Carugo, Dario
Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams
title Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams
title_full Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams
title_fullStr Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams
title_full_unstemmed Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams
title_short Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams
title_sort physical vein models to quantify the flow performance of sclerosing foams
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536569/
https://www.ncbi.nlm.nih.gov/pubmed/31165068
http://dx.doi.org/10.3389/fbioe.2019.00109
work_keys_str_mv AT bottaroelisabetta physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams
AT patersonjemma physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams
AT zhangxunli physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams
AT hillmartyn physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams
AT patelvenishaa physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams
AT jonesstephena physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams
AT lewisandrewl physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams
AT millartimothym physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams
AT carugodario physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams