Cargando…
Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams
Foam sclerotherapy is clinically employed to treat varicose veins. It involves intravenous injection of foamed surfactant agents causing endothelial wall damage and vessel shrinkage, leading to subsequent neovascularization. Foam production methods used clinically include manual techniques, such as...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536569/ https://www.ncbi.nlm.nih.gov/pubmed/31165068 http://dx.doi.org/10.3389/fbioe.2019.00109 |
_version_ | 1783421777177739264 |
---|---|
author | Bottaro, Elisabetta Paterson, Jemma Zhang, Xunli Hill, Martyn Patel, Venisha A. Jones, Stephen A. Lewis, Andrew L. Millar, Timothy M. Carugo, Dario |
author_facet | Bottaro, Elisabetta Paterson, Jemma Zhang, Xunli Hill, Martyn Patel, Venisha A. Jones, Stephen A. Lewis, Andrew L. Millar, Timothy M. Carugo, Dario |
author_sort | Bottaro, Elisabetta |
collection | PubMed |
description | Foam sclerotherapy is clinically employed to treat varicose veins. It involves intravenous injection of foamed surfactant agents causing endothelial wall damage and vessel shrinkage, leading to subsequent neovascularization. Foam production methods used clinically include manual techniques, such as the Double Syringe System (DSS) and Tessari (TSS) methods. Pre-clinical in-vitro studies are conducted to characterize the performance of sclerosing agents; however, the experimental models used often do not replicate physiologically relevant physical and biological conditions. In this study, physical vein models (PVMs) were developed and employed for the first time to characterize the flow behavior of sclerosing foams. PVMs were fabricated in polydimethylsiloxane (PDMS) by replica molding, and were designed to mimic qualitative geometrical characteristics of veins. Foam behavior was investigated as a function of different physical variables, namely (i) geometry of the vein model (i.e., physiological vs. varicose vein), (ii) foam production technique, and (iii) flow rate of a blood surrogate. The experimental set-up consisted of a PVM positioned on an inclined platform, a syringe pump to control the flow rate of a blood substitute, and a pressure transducer. The static pressure of the blood surrogate at the PVM inlet was measured upon foam administration. The recorded pressure-time curves were analyzed to quantify metrics of foam behavior, with a particular focus on foam expansion and degradation dynamics. Results showed that DSS and TSS foams had similar expansion rate in the physiological PVM, whilst DSS foam had lower expansion rate in the varicose PVM compared to TSS foam. The degradation rate of DSS foam was lower than TSS foam, in both model architectures. Moreover, the background flow rate had a significant effect on foam behavior, enhancing foam displacement rate in both types of PVM. |
format | Online Article Text |
id | pubmed-6536569 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-65365692019-06-04 Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams Bottaro, Elisabetta Paterson, Jemma Zhang, Xunli Hill, Martyn Patel, Venisha A. Jones, Stephen A. Lewis, Andrew L. Millar, Timothy M. Carugo, Dario Front Bioeng Biotechnol Bioengineering and Biotechnology Foam sclerotherapy is clinically employed to treat varicose veins. It involves intravenous injection of foamed surfactant agents causing endothelial wall damage and vessel shrinkage, leading to subsequent neovascularization. Foam production methods used clinically include manual techniques, such as the Double Syringe System (DSS) and Tessari (TSS) methods. Pre-clinical in-vitro studies are conducted to characterize the performance of sclerosing agents; however, the experimental models used often do not replicate physiologically relevant physical and biological conditions. In this study, physical vein models (PVMs) were developed and employed for the first time to characterize the flow behavior of sclerosing foams. PVMs were fabricated in polydimethylsiloxane (PDMS) by replica molding, and were designed to mimic qualitative geometrical characteristics of veins. Foam behavior was investigated as a function of different physical variables, namely (i) geometry of the vein model (i.e., physiological vs. varicose vein), (ii) foam production technique, and (iii) flow rate of a blood surrogate. The experimental set-up consisted of a PVM positioned on an inclined platform, a syringe pump to control the flow rate of a blood substitute, and a pressure transducer. The static pressure of the blood surrogate at the PVM inlet was measured upon foam administration. The recorded pressure-time curves were analyzed to quantify metrics of foam behavior, with a particular focus on foam expansion and degradation dynamics. Results showed that DSS and TSS foams had similar expansion rate in the physiological PVM, whilst DSS foam had lower expansion rate in the varicose PVM compared to TSS foam. The degradation rate of DSS foam was lower than TSS foam, in both model architectures. Moreover, the background flow rate had a significant effect on foam behavior, enhancing foam displacement rate in both types of PVM. Frontiers Media S.A. 2019-05-21 /pmc/articles/PMC6536569/ /pubmed/31165068 http://dx.doi.org/10.3389/fbioe.2019.00109 Text en Copyright © 2019 Bottaro, Paterson, Zhang, Hill, Patel, Jones, Lewis, Millar and Carugo. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Bottaro, Elisabetta Paterson, Jemma Zhang, Xunli Hill, Martyn Patel, Venisha A. Jones, Stephen A. Lewis, Andrew L. Millar, Timothy M. Carugo, Dario Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams |
title | Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams |
title_full | Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams |
title_fullStr | Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams |
title_full_unstemmed | Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams |
title_short | Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams |
title_sort | physical vein models to quantify the flow performance of sclerosing foams |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536569/ https://www.ncbi.nlm.nih.gov/pubmed/31165068 http://dx.doi.org/10.3389/fbioe.2019.00109 |
work_keys_str_mv | AT bottaroelisabetta physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams AT patersonjemma physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams AT zhangxunli physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams AT hillmartyn physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams AT patelvenishaa physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams AT jonesstephena physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams AT lewisandrewl physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams AT millartimothym physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams AT carugodario physicalveinmodelstoquantifytheflowperformanceofsclerosingfoams |