Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair
We examined the possible reasons for common carotid artery chimney stent graft occlusion through computational fluid dynamics analyses of follow-up imaging of a patient-specific aortic configuration reconstructed from computed tomography aortography. Anatomic and hemodynamic parameters were extracte...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536778/ https://www.ncbi.nlm.nih.gov/pubmed/31193609 http://dx.doi.org/10.1016/j.jvscit.2019.02.007 |
_version_ | 1783421843232784384 |
---|---|
author | Tricarico, Rosamaria He, Yong Tran-Son-Tay, Roger Laquian, Liza Beck, Adam W. Berceli, Scott A. |
author_facet | Tricarico, Rosamaria He, Yong Tran-Son-Tay, Roger Laquian, Liza Beck, Adam W. Berceli, Scott A. |
author_sort | Tricarico, Rosamaria |
collection | PubMed |
description | We examined the possible reasons for common carotid artery chimney stent graft occlusion through computational fluid dynamics analyses of follow-up imaging of a patient-specific aortic configuration reconstructed from computed tomography aortography. Anatomic and hemodynamic parameters were extracted for the bilateral common carotid and subclavian arteries before and after endograft placement. Results suggested that postoperative reduction in lumen diameter within the chimney stent graft combined with an increased flow rate led to complex hemodynamics with high wall shear stress, probably resulting in high-shear thrombogenesis and chimney stent graft occlusion 2.6 years after the primary repair. Early postoperative duplex ultrasound imaging might help identify at-risk conditions. |
format | Online Article Text |
id | pubmed-6536778 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-65367782019-06-03 Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair Tricarico, Rosamaria He, Yong Tran-Son-Tay, Roger Laquian, Liza Beck, Adam W. Berceli, Scott A. J Vasc Surg Cases Innov Tech Hybrid reconstruction We examined the possible reasons for common carotid artery chimney stent graft occlusion through computational fluid dynamics analyses of follow-up imaging of a patient-specific aortic configuration reconstructed from computed tomography aortography. Anatomic and hemodynamic parameters were extracted for the bilateral common carotid and subclavian arteries before and after endograft placement. Results suggested that postoperative reduction in lumen diameter within the chimney stent graft combined with an increased flow rate led to complex hemodynamics with high wall shear stress, probably resulting in high-shear thrombogenesis and chimney stent graft occlusion 2.6 years after the primary repair. Early postoperative duplex ultrasound imaging might help identify at-risk conditions. Elsevier 2019-05-25 /pmc/articles/PMC6536778/ /pubmed/31193609 http://dx.doi.org/10.1016/j.jvscit.2019.02.007 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Hybrid reconstruction Tricarico, Rosamaria He, Yong Tran-Son-Tay, Roger Laquian, Liza Beck, Adam W. Berceli, Scott A. Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair |
title | Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair |
title_full | Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair |
title_fullStr | Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair |
title_full_unstemmed | Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair |
title_short | Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair |
title_sort | anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair |
topic | Hybrid reconstruction |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536778/ https://www.ncbi.nlm.nih.gov/pubmed/31193609 http://dx.doi.org/10.1016/j.jvscit.2019.02.007 |
work_keys_str_mv | AT tricaricorosamaria anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair AT heyong anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair AT transontayroger anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair AT laquianliza anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair AT beckadamw anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair AT berceliscotta anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair |