Cargando…

Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair

We examined the possible reasons for common carotid artery chimney stent graft occlusion through computational fluid dynamics analyses of follow-up imaging of a patient-specific aortic configuration reconstructed from computed tomography aortography. Anatomic and hemodynamic parameters were extracte...

Descripción completa

Detalles Bibliográficos
Autores principales: Tricarico, Rosamaria, He, Yong, Tran-Son-Tay, Roger, Laquian, Liza, Beck, Adam W., Berceli, Scott A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536778/
https://www.ncbi.nlm.nih.gov/pubmed/31193609
http://dx.doi.org/10.1016/j.jvscit.2019.02.007
_version_ 1783421843232784384
author Tricarico, Rosamaria
He, Yong
Tran-Son-Tay, Roger
Laquian, Liza
Beck, Adam W.
Berceli, Scott A.
author_facet Tricarico, Rosamaria
He, Yong
Tran-Son-Tay, Roger
Laquian, Liza
Beck, Adam W.
Berceli, Scott A.
author_sort Tricarico, Rosamaria
collection PubMed
description We examined the possible reasons for common carotid artery chimney stent graft occlusion through computational fluid dynamics analyses of follow-up imaging of a patient-specific aortic configuration reconstructed from computed tomography aortography. Anatomic and hemodynamic parameters were extracted for the bilateral common carotid and subclavian arteries before and after endograft placement. Results suggested that postoperative reduction in lumen diameter within the chimney stent graft combined with an increased flow rate led to complex hemodynamics with high wall shear stress, probably resulting in high-shear thrombogenesis and chimney stent graft occlusion 2.6 years after the primary repair. Early postoperative duplex ultrasound imaging might help identify at-risk conditions.
format Online
Article
Text
id pubmed-6536778
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-65367782019-06-03 Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair Tricarico, Rosamaria He, Yong Tran-Son-Tay, Roger Laquian, Liza Beck, Adam W. Berceli, Scott A. J Vasc Surg Cases Innov Tech Hybrid reconstruction We examined the possible reasons for common carotid artery chimney stent graft occlusion through computational fluid dynamics analyses of follow-up imaging of a patient-specific aortic configuration reconstructed from computed tomography aortography. Anatomic and hemodynamic parameters were extracted for the bilateral common carotid and subclavian arteries before and after endograft placement. Results suggested that postoperative reduction in lumen diameter within the chimney stent graft combined with an increased flow rate led to complex hemodynamics with high wall shear stress, probably resulting in high-shear thrombogenesis and chimney stent graft occlusion 2.6 years after the primary repair. Early postoperative duplex ultrasound imaging might help identify at-risk conditions. Elsevier 2019-05-25 /pmc/articles/PMC6536778/ /pubmed/31193609 http://dx.doi.org/10.1016/j.jvscit.2019.02.007 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Hybrid reconstruction
Tricarico, Rosamaria
He, Yong
Tran-Son-Tay, Roger
Laquian, Liza
Beck, Adam W.
Berceli, Scott A.
Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair
title Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair
title_full Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair
title_fullStr Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair
title_full_unstemmed Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair
title_short Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair
title_sort anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair
topic Hybrid reconstruction
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536778/
https://www.ncbi.nlm.nih.gov/pubmed/31193609
http://dx.doi.org/10.1016/j.jvscit.2019.02.007
work_keys_str_mv AT tricaricorosamaria anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair
AT heyong anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair
AT transontayroger anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair
AT laquianliza anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair
AT beckadamw anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair
AT berceliscotta anatomicandhemodynamicinvestigationofanoccludedcommoncarotidchimneystentgraftforhybridthoracicaorticaneurysmrepair