Characterization of a Novel 3 Megavolt Linear Accelerator for Dedicated Intracranial Stereotactic Radiosurgery

The purpose of this article is to investigate and characterize from a physics perspective the Zap-X (ZAP Surgical Systems, Inc., San Carlos, CA), a new, dedicated self-contained and self-shielded radiosurgery system, focusing on beam energy and performance, leakage, radiation safety, dose delivery a...

Descripción completa

Detalles Bibliográficos
Autores principales: Weidlich, Georg A., Bodduluri, Mohan, Achkire, Younes, Lee, Chris, Adler, John R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6538235/
https://www.ncbi.nlm.nih.gov/pubmed/31183264
http://dx.doi.org/10.7759/cureus.4275
_version_ 1783422162627985408
author Weidlich, Georg A.
Bodduluri, Mohan
Achkire, Younes
Lee, Chris
Adler, John R.
author_facet Weidlich, Georg A.
Bodduluri, Mohan
Achkire, Younes
Lee, Chris
Adler, John R.
author_sort Weidlich, Georg A.
collection PubMed
description The purpose of this article is to investigate and characterize from a physics perspective the Zap-X (ZAP Surgical Systems, Inc., San Carlos, CA), a new, dedicated self-contained and self-shielded radiosurgery system, focusing on beam energy and performance, leakage, radiation safety, dose delivery accuracy, regulations, quality assurance, and treatment planning. This investigation is required to establish the mechanical and overall performance specifications of the system and to establish baseline parameters for future clinical usage. The applied methods include measurements of energy, focal spot size, beam performance, dosimetry, beam data, treatment planning system, leakage radiation, acceptance testing, and commissioning. The results of the characterization reveal a 3 megavolt (MV) linear accelerator (linac) with a focal spot size of 2 mm, a dose rate of 1,500 MU/min at the isocenter with a dose linearity of 3%, a beam penumbra of less than 3 mm, and beam symmetry of less than 2%. Beam performance, as well as dosimetry characteristics, are suitable for intracranial radiosurgery. It can be concluded that the system was found to meet safety, accuracy, and performance requirements widely accepted in the radiation oncology and radiosurgery industry. Furthermore, the system was shown to meet the practical, clinical needs of the radiosurgery community.
format Online
Article
Text
id pubmed-6538235
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-65382352019-06-10 Characterization of a Novel 3 Megavolt Linear Accelerator for Dedicated Intracranial Stereotactic Radiosurgery Weidlich, Georg A. Bodduluri, Mohan Achkire, Younes Lee, Chris Adler, John R. Cureus Medical Physics The purpose of this article is to investigate and characterize from a physics perspective the Zap-X (ZAP Surgical Systems, Inc., San Carlos, CA), a new, dedicated self-contained and self-shielded radiosurgery system, focusing on beam energy and performance, leakage, radiation safety, dose delivery accuracy, regulations, quality assurance, and treatment planning. This investigation is required to establish the mechanical and overall performance specifications of the system and to establish baseline parameters for future clinical usage. The applied methods include measurements of energy, focal spot size, beam performance, dosimetry, beam data, treatment planning system, leakage radiation, acceptance testing, and commissioning. The results of the characterization reveal a 3 megavolt (MV) linear accelerator (linac) with a focal spot size of 2 mm, a dose rate of 1,500 MU/min at the isocenter with a dose linearity of 3%, a beam penumbra of less than 3 mm, and beam symmetry of less than 2%. Beam performance, as well as dosimetry characteristics, are suitable for intracranial radiosurgery. It can be concluded that the system was found to meet safety, accuracy, and performance requirements widely accepted in the radiation oncology and radiosurgery industry. Furthermore, the system was shown to meet the practical, clinical needs of the radiosurgery community. Cureus 2019-03-19 /pmc/articles/PMC6538235/ /pubmed/31183264 http://dx.doi.org/10.7759/cureus.4275 Text en Copyright © 2019, Weidlich et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Medical Physics
Weidlich, Georg A.
Bodduluri, Mohan
Achkire, Younes
Lee, Chris
Adler, John R.
Characterization of a Novel 3 Megavolt Linear Accelerator for Dedicated Intracranial Stereotactic Radiosurgery
title Characterization of a Novel 3 Megavolt Linear Accelerator for Dedicated Intracranial Stereotactic Radiosurgery
title_full Characterization of a Novel 3 Megavolt Linear Accelerator for Dedicated Intracranial Stereotactic Radiosurgery
title_fullStr Characterization of a Novel 3 Megavolt Linear Accelerator for Dedicated Intracranial Stereotactic Radiosurgery
title_full_unstemmed Characterization of a Novel 3 Megavolt Linear Accelerator for Dedicated Intracranial Stereotactic Radiosurgery
title_short Characterization of a Novel 3 Megavolt Linear Accelerator for Dedicated Intracranial Stereotactic Radiosurgery
title_sort characterization of a novel 3 megavolt linear accelerator for dedicated intracranial stereotactic radiosurgery
topic Medical Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6538235/
https://www.ncbi.nlm.nih.gov/pubmed/31183264
http://dx.doi.org/10.7759/cureus.4275
work_keys_str_mv AT weidlichgeorga characterizationofanovel3megavoltlinearacceleratorfordedicatedintracranialstereotacticradiosurgery
AT boddulurimohan characterizationofanovel3megavoltlinearacceleratorfordedicatedintracranialstereotacticradiosurgery
AT achkireyounes characterizationofanovel3megavoltlinearacceleratorfordedicatedintracranialstereotacticradiosurgery
AT leechris characterizationofanovel3megavoltlinearacceleratorfordedicatedintracranialstereotacticradiosurgery
AT adlerjohnr characterizationofanovel3megavoltlinearacceleratorfordedicatedintracranialstereotacticradiosurgery