Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique

BACKGROUND: Craniospinal irradiation (CSI) of medulloblastoma poses technological challenges due to the involvement of large treatment volume. Commonly, the whole treatment length is covered with two different isocentric plans in which the junction is shifted after every five fractions to overcome t...

Descripción completa

Detalles Bibliográficos
Autores principales: Gurjar, O.P., Arya, R., Goyal, H., Handa, P., Bagdare, P., Khan, A., Paliwal, R.K., Mishra, S.P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Biomedical Physics and Engineering 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6538910/
https://www.ncbi.nlm.nih.gov/pubmed/31214520
_version_ 1783422262030893056
author Gurjar, O.P.
Arya, R.
Goyal, H.
Handa, P.
Bagdare, P.
Khan, A.
Paliwal, R.K.
Mishra, S.P.
author_facet Gurjar, O.P.
Arya, R.
Goyal, H.
Handa, P.
Bagdare, P.
Khan, A.
Paliwal, R.K.
Mishra, S.P.
author_sort Gurjar, O.P.
collection PubMed
description BACKGROUND: Craniospinal irradiation (CSI) of medulloblastoma poses technological challenges due to the involvement of large treatment volume. Commonly, the whole treatment length is covered with two different isocentric plans in which the junction is shifted after every five fractions to overcome the possibility of hot and cold spot. OBJECTIVE: This study aims to evaluate dosimetrically and clinically the innovative planning technique for the CSI which doesn’t need re-planning and re-setup of patients after every five fractions. MATERIAL AND METHODS: Computed tomography was done for fifteen (ten children and five adults) patients diagnosed with medulloblastoma. Treatment planning for 36 Gray (Gy) in 20 fractions (#) at the rate of 1.8Gy/# was done on the treatment planning system. A single plan for children was created with two bilateral fields of 6 Mega Voltage (MV) energy for cranium and one posterior field of 6 MV for spinal cord (C1-S2). Two plans for adult patients were created, first plan was with two bilateral fields of 6 MV for cranium and two posterior oblique fields of 6 MV for cervical and the part of thoracic spinal cord (up to T8-T9). The second plan was with a single posterior field of 15 MV covering remaining thoracic (T8-T9 to T12), lumbar and sacrum (up to lower border of S2) spine. After careful evaluation of all the plans, treatment was delivered; acute toxicities were recorded. RESULTS: 95% of prescribed dose was received by more than 95% of planning target volume in all the plans with the acceptable hot spot and good homogeneity index. All the patients reported common radiation induced acute toxicities (headache, vomiting, weakness) during radiotherapy. CONCLUSION: The new planning technique for CSI has acceptable dosimetric and acute clinical possibilities; therefore it can be used for CSI for improved homogeneous dose delivery.
format Online
Article
Text
id pubmed-6538910
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Journal of Biomedical Physics and Engineering
record_format MEDLINE/PubMed
spelling pubmed-65389102019-06-18 Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique Gurjar, O.P. Arya, R. Goyal, H. Handa, P. Bagdare, P. Khan, A. Paliwal, R.K. Mishra, S.P. J Biomed Phys Eng Original Article BACKGROUND: Craniospinal irradiation (CSI) of medulloblastoma poses technological challenges due to the involvement of large treatment volume. Commonly, the whole treatment length is covered with two different isocentric plans in which the junction is shifted after every five fractions to overcome the possibility of hot and cold spot. OBJECTIVE: This study aims to evaluate dosimetrically and clinically the innovative planning technique for the CSI which doesn’t need re-planning and re-setup of patients after every five fractions. MATERIAL AND METHODS: Computed tomography was done for fifteen (ten children and five adults) patients diagnosed with medulloblastoma. Treatment planning for 36 Gray (Gy) in 20 fractions (#) at the rate of 1.8Gy/# was done on the treatment planning system. A single plan for children was created with two bilateral fields of 6 Mega Voltage (MV) energy for cranium and one posterior field of 6 MV for spinal cord (C1-S2). Two plans for adult patients were created, first plan was with two bilateral fields of 6 MV for cranium and two posterior oblique fields of 6 MV for cervical and the part of thoracic spinal cord (up to T8-T9). The second plan was with a single posterior field of 15 MV covering remaining thoracic (T8-T9 to T12), lumbar and sacrum (up to lower border of S2) spine. After careful evaluation of all the plans, treatment was delivered; acute toxicities were recorded. RESULTS: 95% of prescribed dose was received by more than 95% of planning target volume in all the plans with the acceptable hot spot and good homogeneity index. All the patients reported common radiation induced acute toxicities (headache, vomiting, weakness) during radiotherapy. CONCLUSION: The new planning technique for CSI has acceptable dosimetric and acute clinical possibilities; therefore it can be used for CSI for improved homogeneous dose delivery. Journal of Biomedical Physics and Engineering 2019-04-01 /pmc/articles/PMC6538910/ /pubmed/31214520 Text en Copyright: © Journal of Biomedical Physics and Engineering http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Gurjar, O.P.
Arya, R.
Goyal, H.
Handa, P.
Bagdare, P.
Khan, A.
Paliwal, R.K.
Mishra, S.P.
Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
title Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
title_full Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
title_fullStr Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
title_full_unstemmed Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
title_short Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
title_sort craniospinal irradiation in medulloblastoma using high energy medical linear accelerator: an innovative approach to planning technique
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6538910/
https://www.ncbi.nlm.nih.gov/pubmed/31214520
work_keys_str_mv AT gurjarop craniospinalirradiationinmedulloblastomausinghighenergymedicallinearacceleratoraninnovativeapproachtoplanningtechnique
AT aryar craniospinalirradiationinmedulloblastomausinghighenergymedicallinearacceleratoraninnovativeapproachtoplanningtechnique
AT goyalh craniospinalirradiationinmedulloblastomausinghighenergymedicallinearacceleratoraninnovativeapproachtoplanningtechnique
AT handap craniospinalirradiationinmedulloblastomausinghighenergymedicallinearacceleratoraninnovativeapproachtoplanningtechnique
AT bagdarep craniospinalirradiationinmedulloblastomausinghighenergymedicallinearacceleratoraninnovativeapproachtoplanningtechnique
AT khana craniospinalirradiationinmedulloblastomausinghighenergymedicallinearacceleratoraninnovativeapproachtoplanningtechnique
AT paliwalrk craniospinalirradiationinmedulloblastomausinghighenergymedicallinearacceleratoraninnovativeapproachtoplanningtechnique
AT mishrasp craniospinalirradiationinmedulloblastomausinghighenergymedicallinearacceleratoraninnovativeapproachtoplanningtechnique