Cargando…

The Intergranular Corrosion Susceptibility of Metastable Austenitic Cr–Mn–Ni–N–Cu High-Strength Stainless Steel under Various Heat Treatments

The intergranular corrosion (IGC) behavior of a new metastable austenitic Cr–Mn–Ni–N–Cu high-strength stainless steel under various heat treatments was studied. The samples were solution treated at 1050 °C for 30 min and then aged at 600 to 900 °C for 10 to 300 min, respectively. The IGC susceptibil...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Guangming, Liu, Yuanyuan, Cheng, Yawen, Li, Jin, Jiang, Yiming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539159/
https://www.ncbi.nlm.nih.gov/pubmed/31035439
http://dx.doi.org/10.3390/ma12091385
_version_ 1783422320022388736
author Liu, Guangming
Liu, Yuanyuan
Cheng, Yawen
Li, Jin
Jiang, Yiming
author_facet Liu, Guangming
Liu, Yuanyuan
Cheng, Yawen
Li, Jin
Jiang, Yiming
author_sort Liu, Guangming
collection PubMed
description The intergranular corrosion (IGC) behavior of a new metastable austenitic Cr–Mn–Ni–N–Cu high-strength stainless steel under various heat treatments was studied. The samples were solution treated at 1050 °C for 30 min and then aged at 600 to 900 °C for 10 to 300 min, respectively. The IGC susceptibility of aged samples was investigated using a double-loop electrochemical potentiokinetic reactivation (DL-EPR) test in a solution of 0.1 M H(2)SO(4) and 0.002 M KSCN and the 10% oxalic acid etch. The surface morphologies of samples were characterized using optical microscopy and the scanning electron microscopy after electrochemical tests. Two time-temperature-sensitization diagrams were plotted based on the DL-EPR test and oxalic acid etching. No IGC and precipitate were observed for samples aged at 600 °C and 900 °C. For samples aged at 650 °C to 750 °C, the IGC susceptibility and the amount of precipitate both increased with the extended aging time. For samples aged at 800 °C and 850 °C, the amount of precipitate increased as the aging time was prolonged. However, only the sample aged at 800 °C for 60 min showed slight intergranular corrosion in the DL-EPR test. The IGC of the Cr–Mn–Ni–N–Cu austenitic stainless steel originated from the precipitation of Cr(23)C(6) and Cr(2)N at the grain boundaries. The chromium-depleted zones near grain boundaries stood as the corrosion nucleation sites, but the dissolution of the weak area followed a consistent crystallographic orientation along each grain boundary.
format Online
Article
Text
id pubmed-6539159
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65391592019-06-05 The Intergranular Corrosion Susceptibility of Metastable Austenitic Cr–Mn–Ni–N–Cu High-Strength Stainless Steel under Various Heat Treatments Liu, Guangming Liu, Yuanyuan Cheng, Yawen Li, Jin Jiang, Yiming Materials (Basel) Article The intergranular corrosion (IGC) behavior of a new metastable austenitic Cr–Mn–Ni–N–Cu high-strength stainless steel under various heat treatments was studied. The samples were solution treated at 1050 °C for 30 min and then aged at 600 to 900 °C for 10 to 300 min, respectively. The IGC susceptibility of aged samples was investigated using a double-loop electrochemical potentiokinetic reactivation (DL-EPR) test in a solution of 0.1 M H(2)SO(4) and 0.002 M KSCN and the 10% oxalic acid etch. The surface morphologies of samples were characterized using optical microscopy and the scanning electron microscopy after electrochemical tests. Two time-temperature-sensitization diagrams were plotted based on the DL-EPR test and oxalic acid etching. No IGC and precipitate were observed for samples aged at 600 °C and 900 °C. For samples aged at 650 °C to 750 °C, the IGC susceptibility and the amount of precipitate both increased with the extended aging time. For samples aged at 800 °C and 850 °C, the amount of precipitate increased as the aging time was prolonged. However, only the sample aged at 800 °C for 60 min showed slight intergranular corrosion in the DL-EPR test. The IGC of the Cr–Mn–Ni–N–Cu austenitic stainless steel originated from the precipitation of Cr(23)C(6) and Cr(2)N at the grain boundaries. The chromium-depleted zones near grain boundaries stood as the corrosion nucleation sites, but the dissolution of the weak area followed a consistent crystallographic orientation along each grain boundary. MDPI 2019-04-29 /pmc/articles/PMC6539159/ /pubmed/31035439 http://dx.doi.org/10.3390/ma12091385 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Guangming
Liu, Yuanyuan
Cheng, Yawen
Li, Jin
Jiang, Yiming
The Intergranular Corrosion Susceptibility of Metastable Austenitic Cr–Mn–Ni–N–Cu High-Strength Stainless Steel under Various Heat Treatments
title The Intergranular Corrosion Susceptibility of Metastable Austenitic Cr–Mn–Ni–N–Cu High-Strength Stainless Steel under Various Heat Treatments
title_full The Intergranular Corrosion Susceptibility of Metastable Austenitic Cr–Mn–Ni–N–Cu High-Strength Stainless Steel under Various Heat Treatments
title_fullStr The Intergranular Corrosion Susceptibility of Metastable Austenitic Cr–Mn–Ni–N–Cu High-Strength Stainless Steel under Various Heat Treatments
title_full_unstemmed The Intergranular Corrosion Susceptibility of Metastable Austenitic Cr–Mn–Ni–N–Cu High-Strength Stainless Steel under Various Heat Treatments
title_short The Intergranular Corrosion Susceptibility of Metastable Austenitic Cr–Mn–Ni–N–Cu High-Strength Stainless Steel under Various Heat Treatments
title_sort intergranular corrosion susceptibility of metastable austenitic cr–mn–ni–n–cu high-strength stainless steel under various heat treatments
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539159/
https://www.ncbi.nlm.nih.gov/pubmed/31035439
http://dx.doi.org/10.3390/ma12091385
work_keys_str_mv AT liuguangming theintergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments
AT liuyuanyuan theintergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments
AT chengyawen theintergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments
AT lijin theintergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments
AT jiangyiming theintergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments
AT liuguangming intergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments
AT liuyuanyuan intergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments
AT chengyawen intergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments
AT lijin intergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments
AT jiangyiming intergranularcorrosionsusceptibilityofmetastableausteniticcrmnnincuhighstrengthstainlesssteelundervariousheattreatments