Chromium, one of the top five toxic heavy metals ranked according to significance in public health by WHO, exists as Cr(III) which is naturally occurring or Cr(VI) which is anthropogenic in origin. The EPA specifies the maximum contaminant level in drinking water to be 10(−6) M or 0.1 mg/L or 100 pp...

Descripción completa

Detalles Bibliográficos
Autores principales: Shahim, Suman, Sukesan, Revathi, Sarangadharan, Indu, Wang, Yu-Lin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539384/
https://www.ncbi.nlm.nih.gov/pubmed/31035499
http://dx.doi.org/10.3390/s19091969
_version_ 1783422375250886656
author Shahim, Suman
Sukesan, Revathi
Sarangadharan, Indu
Wang, Yu-Lin
author_facet Shahim, Suman
Sukesan, Revathi
Sarangadharan, Indu
Wang, Yu-Lin
author_sort Shahim, Suman
collection PubMed
description Chromium, one of the top five toxic heavy metals ranked according to significance in public health by WHO, exists as Cr(III) which is naturally occurring or Cr(VI) which is anthropogenic in origin. The EPA specifies the maximum contaminant level in drinking water to be 10(−6) M or 0.1 mg/L or 100 ppb for the total dissolved Cr. To ensure the water consumed by the population has these pollutants below the safe threshold, this report demonstrates a field effect transistor (FET) based sensor design incorporating a highly target specific ion-selective membrane combined with extended gate technology which manifests sensitivity exceeding the Nernst limit aided by the high field effect in the short gap region of extended gate technology. Characterization and repeated testing of the portable device revealed a commendable calibration sensitivity of 99 mV/log [Cr(3+)] and 71 mV/log [Cr(6+)] for Cr(III) and Cr(VI) respectively, well surpassing the Nernst limits of sensitivity and offering a detection limit lower than ion-selective electrodes (10(−6) M), and comparable to the expensive benchtop laboratory instrument, ICP-MS. This report presents a robust, easy to fabricate, economic and efficient handheld biosensor to detect the chromium in a liquid sample whether it exists as Cr(III) or Cr(VI).
format Online
Article
Text
id pubmed-6539384
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65393842019-06-04 Multiplexed Ultra-Sensitive Detection of Cr(III) and Cr(VI) Ion by FET Sensor Array in a Liquid Medium Shahim, Suman Sukesan, Revathi Sarangadharan, Indu Wang, Yu-Lin Sensors (Basel) Article Chromium, one of the top five toxic heavy metals ranked according to significance in public health by WHO, exists as Cr(III) which is naturally occurring or Cr(VI) which is anthropogenic in origin. The EPA specifies the maximum contaminant level in drinking water to be 10(−6) M or 0.1 mg/L or 100 ppb for the total dissolved Cr. To ensure the water consumed by the population has these pollutants below the safe threshold, this report demonstrates a field effect transistor (FET) based sensor design incorporating a highly target specific ion-selective membrane combined with extended gate technology which manifests sensitivity exceeding the Nernst limit aided by the high field effect in the short gap region of extended gate technology. Characterization and repeated testing of the portable device revealed a commendable calibration sensitivity of 99 mV/log [Cr(3+)] and 71 mV/log [Cr(6+)] for Cr(III) and Cr(VI) respectively, well surpassing the Nernst limits of sensitivity and offering a detection limit lower than ion-selective electrodes (10(−6) M), and comparable to the expensive benchtop laboratory instrument, ICP-MS. This report presents a robust, easy to fabricate, economic and efficient handheld biosensor to detect the chromium in a liquid sample whether it exists as Cr(III) or Cr(VI). MDPI 2019-04-26 /pmc/articles/PMC6539384/ /pubmed/31035499 http://dx.doi.org/10.3390/s19091969 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shahim, Suman
Sukesan, Revathi
Sarangadharan, Indu
Wang, Yu-Lin
Multiplexed Ultra-Sensitive Detection of Cr(III) and Cr(VI) Ion by FET Sensor Array in a Liquid Medium
title Multiplexed Ultra-Sensitive Detection of Cr(III) and Cr(VI) Ion by FET Sensor Array in a Liquid Medium
title_full Multiplexed Ultra-Sensitive Detection of Cr(III) and Cr(VI) Ion by FET Sensor Array in a Liquid Medium
title_fullStr Multiplexed Ultra-Sensitive Detection of Cr(III) and Cr(VI) Ion by FET Sensor Array in a Liquid Medium
title_full_unstemmed Multiplexed Ultra-Sensitive Detection of Cr(III) and Cr(VI) Ion by FET Sensor Array in a Liquid Medium
title_short Multiplexed Ultra-Sensitive Detection of Cr(III) and Cr(VI) Ion by FET Sensor Array in a Liquid Medium
title_sort multiplexed ultra-sensitive detection of cr(iii) and cr(vi) ion by fet sensor array in a liquid medium
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539384/
https://www.ncbi.nlm.nih.gov/pubmed/31035499
http://dx.doi.org/10.3390/s19091969
work_keys_str_mv AT shahimsuman multiplexedultrasensitivedetectionofcriiiandcrviionbyfetsensorarrayinaliquidmedium
AT sukesanrevathi multiplexedultrasensitivedetectionofcriiiandcrviionbyfetsensorarrayinaliquidmedium
AT sarangadharanindu multiplexedultrasensitivedetectionofcriiiandcrviionbyfetsensorarrayinaliquidmedium
AT wangyulin multiplexedultrasensitivedetectionofcriiiandcrviionbyfetsensorarrayinaliquidmedium