Cargando…

Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation

Mg-based alloys have great potential for development into fixation implants because of their highly biocompatible and biodegradable metallic properties. In this study, we sought to determine the biocompatibility of Mg(60)Zn(35)Ca(5) bulk metallic glass composite (BMGC) with fabricated implants in a...

Descripción completa

Detalles Bibliográficos
Autores principales: Wong, Chin-Chean, Wong, Pei-Chun, Tsai, Pei-Hua, Jang, Jason Shian-Ching, Cheng, Cheng-Kung, Chen, Hsiang-Ho, Chen, Chih-Hwa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539447/
https://www.ncbi.nlm.nih.gov/pubmed/31058825
http://dx.doi.org/10.3390/ijms20092191
_version_ 1783422390716334080
author Wong, Chin-Chean
Wong, Pei-Chun
Tsai, Pei-Hua
Jang, Jason Shian-Ching
Cheng, Cheng-Kung
Chen, Hsiang-Ho
Chen, Chih-Hwa
author_facet Wong, Chin-Chean
Wong, Pei-Chun
Tsai, Pei-Hua
Jang, Jason Shian-Ching
Cheng, Cheng-Kung
Chen, Hsiang-Ho
Chen, Chih-Hwa
author_sort Wong, Chin-Chean
collection PubMed
description Mg-based alloys have great potential for development into fixation implants because of their highly biocompatible and biodegradable metallic properties. In this study, we sought to determine the biocompatibility of Mg(60)Zn(35)Ca(5) bulk metallic glass composite (BMGC) with fabricated implants in a rabbit tendon–bone interference fixation model. We investigated the cellular cytotoxicity of Mg(60)Zn(35)Ca(5) BMGC toward rabbit osteoblasts and compared it with conventional titanium alloy (Ti6Al4V) and polylactic acid (PLA). The results show that Mg(60)Zn(35)Ca(5) BMGC may be classed as slightly toxic on the basis of the standard ISO 10993-5. We further characterized the osteogenic effect of the Mg(60)Zn(35)Ca(5) BMGC extraction medium on rabbit osteoblasts by quantifying extracellular calcium and mineral deposition, as well as cellular alkaline phosphatase activity. The results of these tests were found to be promising. The chemotactic effect of the Mg(60)Zn(35)Ca(5) BMGC extraction medium on rabbit osteoblasts was demonstrated through a transwell migration assay. For the in vivo section of this study, a rabbit tendon–bone interference fixation model was established to determine the biocompatibility and osteogenic potential of Mg(60)Zn(35)Ca(5) BMGC in a created bony tunnel for a period of up to 24 weeks. The results show that Mg(60)Zn(35)Ca(5) BMGC induced considerable new bone formation at the implant site in comparison with conventional titanium alloy after 24 weeks of implantation. In conclusion, this study revealed that Mg(60)Zn(35)Ca(5) BMGC demonstrated adequate biocompatibility and exhibited significant osteogenic potential both in vitro and in vivo. These advantages may be clinically beneficial to the development of Mg(60)Zn(35)Ca(5) BMGC implants for future applications.
format Online
Article
Text
id pubmed-6539447
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65394472019-06-04 Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation Wong, Chin-Chean Wong, Pei-Chun Tsai, Pei-Hua Jang, Jason Shian-Ching Cheng, Cheng-Kung Chen, Hsiang-Ho Chen, Chih-Hwa Int J Mol Sci Article Mg-based alloys have great potential for development into fixation implants because of their highly biocompatible and biodegradable metallic properties. In this study, we sought to determine the biocompatibility of Mg(60)Zn(35)Ca(5) bulk metallic glass composite (BMGC) with fabricated implants in a rabbit tendon–bone interference fixation model. We investigated the cellular cytotoxicity of Mg(60)Zn(35)Ca(5) BMGC toward rabbit osteoblasts and compared it with conventional titanium alloy (Ti6Al4V) and polylactic acid (PLA). The results show that Mg(60)Zn(35)Ca(5) BMGC may be classed as slightly toxic on the basis of the standard ISO 10993-5. We further characterized the osteogenic effect of the Mg(60)Zn(35)Ca(5) BMGC extraction medium on rabbit osteoblasts by quantifying extracellular calcium and mineral deposition, as well as cellular alkaline phosphatase activity. The results of these tests were found to be promising. The chemotactic effect of the Mg(60)Zn(35)Ca(5) BMGC extraction medium on rabbit osteoblasts was demonstrated through a transwell migration assay. For the in vivo section of this study, a rabbit tendon–bone interference fixation model was established to determine the biocompatibility and osteogenic potential of Mg(60)Zn(35)Ca(5) BMGC in a created bony tunnel for a period of up to 24 weeks. The results show that Mg(60)Zn(35)Ca(5) BMGC induced considerable new bone formation at the implant site in comparison with conventional titanium alloy after 24 weeks of implantation. In conclusion, this study revealed that Mg(60)Zn(35)Ca(5) BMGC demonstrated adequate biocompatibility and exhibited significant osteogenic potential both in vitro and in vivo. These advantages may be clinically beneficial to the development of Mg(60)Zn(35)Ca(5) BMGC implants for future applications. MDPI 2019-05-03 /pmc/articles/PMC6539447/ /pubmed/31058825 http://dx.doi.org/10.3390/ijms20092191 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wong, Chin-Chean
Wong, Pei-Chun
Tsai, Pei-Hua
Jang, Jason Shian-Ching
Cheng, Cheng-Kung
Chen, Hsiang-Ho
Chen, Chih-Hwa
Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation
title Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation
title_full Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation
title_fullStr Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation
title_full_unstemmed Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation
title_short Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation
title_sort biocompatibility and osteogenic capacity of mg-zn-ca bulk metallic glass for rabbit tendon-bone interference fixation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539447/
https://www.ncbi.nlm.nih.gov/pubmed/31058825
http://dx.doi.org/10.3390/ijms20092191
work_keys_str_mv AT wongchinchean biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation
AT wongpeichun biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation
AT tsaipeihua biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation
AT jangjasonshianching biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation
AT chengchengkung biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation
AT chenhsiangho biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation
AT chenchihhwa biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation