Cargando…
Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation
Mg-based alloys have great potential for development into fixation implants because of their highly biocompatible and biodegradable metallic properties. In this study, we sought to determine the biocompatibility of Mg(60)Zn(35)Ca(5) bulk metallic glass composite (BMGC) with fabricated implants in a...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539447/ https://www.ncbi.nlm.nih.gov/pubmed/31058825 http://dx.doi.org/10.3390/ijms20092191 |
_version_ | 1783422390716334080 |
---|---|
author | Wong, Chin-Chean Wong, Pei-Chun Tsai, Pei-Hua Jang, Jason Shian-Ching Cheng, Cheng-Kung Chen, Hsiang-Ho Chen, Chih-Hwa |
author_facet | Wong, Chin-Chean Wong, Pei-Chun Tsai, Pei-Hua Jang, Jason Shian-Ching Cheng, Cheng-Kung Chen, Hsiang-Ho Chen, Chih-Hwa |
author_sort | Wong, Chin-Chean |
collection | PubMed |
description | Mg-based alloys have great potential for development into fixation implants because of their highly biocompatible and biodegradable metallic properties. In this study, we sought to determine the biocompatibility of Mg(60)Zn(35)Ca(5) bulk metallic glass composite (BMGC) with fabricated implants in a rabbit tendon–bone interference fixation model. We investigated the cellular cytotoxicity of Mg(60)Zn(35)Ca(5) BMGC toward rabbit osteoblasts and compared it with conventional titanium alloy (Ti6Al4V) and polylactic acid (PLA). The results show that Mg(60)Zn(35)Ca(5) BMGC may be classed as slightly toxic on the basis of the standard ISO 10993-5. We further characterized the osteogenic effect of the Mg(60)Zn(35)Ca(5) BMGC extraction medium on rabbit osteoblasts by quantifying extracellular calcium and mineral deposition, as well as cellular alkaline phosphatase activity. The results of these tests were found to be promising. The chemotactic effect of the Mg(60)Zn(35)Ca(5) BMGC extraction medium on rabbit osteoblasts was demonstrated through a transwell migration assay. For the in vivo section of this study, a rabbit tendon–bone interference fixation model was established to determine the biocompatibility and osteogenic potential of Mg(60)Zn(35)Ca(5) BMGC in a created bony tunnel for a period of up to 24 weeks. The results show that Mg(60)Zn(35)Ca(5) BMGC induced considerable new bone formation at the implant site in comparison with conventional titanium alloy after 24 weeks of implantation. In conclusion, this study revealed that Mg(60)Zn(35)Ca(5) BMGC demonstrated adequate biocompatibility and exhibited significant osteogenic potential both in vitro and in vivo. These advantages may be clinically beneficial to the development of Mg(60)Zn(35)Ca(5) BMGC implants for future applications. |
format | Online Article Text |
id | pubmed-6539447 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-65394472019-06-04 Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation Wong, Chin-Chean Wong, Pei-Chun Tsai, Pei-Hua Jang, Jason Shian-Ching Cheng, Cheng-Kung Chen, Hsiang-Ho Chen, Chih-Hwa Int J Mol Sci Article Mg-based alloys have great potential for development into fixation implants because of their highly biocompatible and biodegradable metallic properties. In this study, we sought to determine the biocompatibility of Mg(60)Zn(35)Ca(5) bulk metallic glass composite (BMGC) with fabricated implants in a rabbit tendon–bone interference fixation model. We investigated the cellular cytotoxicity of Mg(60)Zn(35)Ca(5) BMGC toward rabbit osteoblasts and compared it with conventional titanium alloy (Ti6Al4V) and polylactic acid (PLA). The results show that Mg(60)Zn(35)Ca(5) BMGC may be classed as slightly toxic on the basis of the standard ISO 10993-5. We further characterized the osteogenic effect of the Mg(60)Zn(35)Ca(5) BMGC extraction medium on rabbit osteoblasts by quantifying extracellular calcium and mineral deposition, as well as cellular alkaline phosphatase activity. The results of these tests were found to be promising. The chemotactic effect of the Mg(60)Zn(35)Ca(5) BMGC extraction medium on rabbit osteoblasts was demonstrated through a transwell migration assay. For the in vivo section of this study, a rabbit tendon–bone interference fixation model was established to determine the biocompatibility and osteogenic potential of Mg(60)Zn(35)Ca(5) BMGC in a created bony tunnel for a period of up to 24 weeks. The results show that Mg(60)Zn(35)Ca(5) BMGC induced considerable new bone formation at the implant site in comparison with conventional titanium alloy after 24 weeks of implantation. In conclusion, this study revealed that Mg(60)Zn(35)Ca(5) BMGC demonstrated adequate biocompatibility and exhibited significant osteogenic potential both in vitro and in vivo. These advantages may be clinically beneficial to the development of Mg(60)Zn(35)Ca(5) BMGC implants for future applications. MDPI 2019-05-03 /pmc/articles/PMC6539447/ /pubmed/31058825 http://dx.doi.org/10.3390/ijms20092191 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wong, Chin-Chean Wong, Pei-Chun Tsai, Pei-Hua Jang, Jason Shian-Ching Cheng, Cheng-Kung Chen, Hsiang-Ho Chen, Chih-Hwa Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation |
title | Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation |
title_full | Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation |
title_fullStr | Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation |
title_full_unstemmed | Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation |
title_short | Biocompatibility and Osteogenic Capacity of Mg-Zn-Ca Bulk Metallic Glass for Rabbit Tendon-Bone Interference Fixation |
title_sort | biocompatibility and osteogenic capacity of mg-zn-ca bulk metallic glass for rabbit tendon-bone interference fixation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539447/ https://www.ncbi.nlm.nih.gov/pubmed/31058825 http://dx.doi.org/10.3390/ijms20092191 |
work_keys_str_mv | AT wongchinchean biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation AT wongpeichun biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation AT tsaipeihua biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation AT jangjasonshianching biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation AT chengchengkung biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation AT chenhsiangho biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation AT chenchihhwa biocompatibilityandosteogeniccapacityofmgzncabulkmetallicglassforrabbittendonboneinterferencefixation |