Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation †
Electrical Impedance Tomography (EIT) is a non-invasive detection method to image the conductivity changes inside an observation region by using the electrical measurements at the boundary of this region. In some applications of EIT, the observation domain is infinite and is only accessible from one...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539551/ https://www.ncbi.nlm.nih.gov/pubmed/31052592 http://dx.doi.org/10.3390/s19092060 |
_version_ | 1783422416113893376 |
---|---|
author | Wang, Yu Ren, Shangjie Dong, Feng |
author_facet | Wang, Yu Ren, Shangjie Dong, Feng |
author_sort | Wang, Yu |
collection | PubMed |
description | Electrical Impedance Tomography (EIT) is a non-invasive detection method to image the conductivity changes inside an observation region by using the electrical measurements at the boundary of this region. In some applications of EIT, the observation domain is infinite and is only accessible from one side, which leads to the so-called open EIT (OEIT) problem. Compared with conventional EIT problems, the observation region in OEIT can only be measured from limited projection directions, which makes high resolution imaging much more challenging. To improve the imaging quality of OEIT, a focusing sensor design strategy is proposed based on shape conformal theory. The conformal bijection is used to map a standard EIT sensor defined at a unit circle to a focusing OEIT sensor defined at an upper half plane. A series of numerical and experimental testes are conducted. Compared with the traditional sensor structure, the proposed focusing sensor has higher spatial resolution at the near-electrode region and is good at distinguishing multi-inclusions which are close to each other. |
format | Online Article Text |
id | pubmed-6539551 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-65395512019-06-04 Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation † Wang, Yu Ren, Shangjie Dong, Feng Sensors (Basel) Article Electrical Impedance Tomography (EIT) is a non-invasive detection method to image the conductivity changes inside an observation region by using the electrical measurements at the boundary of this region. In some applications of EIT, the observation domain is infinite and is only accessible from one side, which leads to the so-called open EIT (OEIT) problem. Compared with conventional EIT problems, the observation region in OEIT can only be measured from limited projection directions, which makes high resolution imaging much more challenging. To improve the imaging quality of OEIT, a focusing sensor design strategy is proposed based on shape conformal theory. The conformal bijection is used to map a standard EIT sensor defined at a unit circle to a focusing OEIT sensor defined at an upper half plane. A series of numerical and experimental testes are conducted. Compared with the traditional sensor structure, the proposed focusing sensor has higher spatial resolution at the near-electrode region and is good at distinguishing multi-inclusions which are close to each other. MDPI 2019-05-02 /pmc/articles/PMC6539551/ /pubmed/31052592 http://dx.doi.org/10.3390/s19092060 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Yu Ren, Shangjie Dong, Feng Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation † |
title | Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation † |
title_full | Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation † |
title_fullStr | Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation † |
title_full_unstemmed | Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation † |
title_short | Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation † |
title_sort | focusing sensor design for open electrical impedance tomography based on shape conformal transformation † |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539551/ https://www.ncbi.nlm.nih.gov/pubmed/31052592 http://dx.doi.org/10.3390/s19092060 |
work_keys_str_mv | AT wangyu focusingsensordesignforopenelectricalimpedancetomographybasedonshapeconformaltransformation AT renshangjie focusingsensordesignforopenelectricalimpedancetomographybasedonshapeconformaltransformation AT dongfeng focusingsensordesignforopenelectricalimpedancetomographybasedonshapeconformaltransformation |