Cargando…

Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation †

Electrical Impedance Tomography (EIT) is a non-invasive detection method to image the conductivity changes inside an observation region by using the electrical measurements at the boundary of this region. In some applications of EIT, the observation domain is infinite and is only accessible from one...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yu, Ren, Shangjie, Dong, Feng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539551/
https://www.ncbi.nlm.nih.gov/pubmed/31052592
http://dx.doi.org/10.3390/s19092060
_version_ 1783422416113893376
author Wang, Yu
Ren, Shangjie
Dong, Feng
author_facet Wang, Yu
Ren, Shangjie
Dong, Feng
author_sort Wang, Yu
collection PubMed
description Electrical Impedance Tomography (EIT) is a non-invasive detection method to image the conductivity changes inside an observation region by using the electrical measurements at the boundary of this region. In some applications of EIT, the observation domain is infinite and is only accessible from one side, which leads to the so-called open EIT (OEIT) problem. Compared with conventional EIT problems, the observation region in OEIT can only be measured from limited projection directions, which makes high resolution imaging much more challenging. To improve the imaging quality of OEIT, a focusing sensor design strategy is proposed based on shape conformal theory. The conformal bijection is used to map a standard EIT sensor defined at a unit circle to a focusing OEIT sensor defined at an upper half plane. A series of numerical and experimental testes are conducted. Compared with the traditional sensor structure, the proposed focusing sensor has higher spatial resolution at the near-electrode region and is good at distinguishing multi-inclusions which are close to each other.
format Online
Article
Text
id pubmed-6539551
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65395512019-06-04 Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation † Wang, Yu Ren, Shangjie Dong, Feng Sensors (Basel) Article Electrical Impedance Tomography (EIT) is a non-invasive detection method to image the conductivity changes inside an observation region by using the electrical measurements at the boundary of this region. In some applications of EIT, the observation domain is infinite and is only accessible from one side, which leads to the so-called open EIT (OEIT) problem. Compared with conventional EIT problems, the observation region in OEIT can only be measured from limited projection directions, which makes high resolution imaging much more challenging. To improve the imaging quality of OEIT, a focusing sensor design strategy is proposed based on shape conformal theory. The conformal bijection is used to map a standard EIT sensor defined at a unit circle to a focusing OEIT sensor defined at an upper half plane. A series of numerical and experimental testes are conducted. Compared with the traditional sensor structure, the proposed focusing sensor has higher spatial resolution at the near-electrode region and is good at distinguishing multi-inclusions which are close to each other. MDPI 2019-05-02 /pmc/articles/PMC6539551/ /pubmed/31052592 http://dx.doi.org/10.3390/s19092060 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Yu
Ren, Shangjie
Dong, Feng
Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation †
title Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation †
title_full Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation †
title_fullStr Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation †
title_full_unstemmed Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation †
title_short Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation †
title_sort focusing sensor design for open electrical impedance tomography based on shape conformal transformation †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539551/
https://www.ncbi.nlm.nih.gov/pubmed/31052592
http://dx.doi.org/10.3390/s19092060
work_keys_str_mv AT wangyu focusingsensordesignforopenelectricalimpedancetomographybasedonshapeconformaltransformation
AT renshangjie focusingsensordesignforopenelectricalimpedancetomographybasedonshapeconformaltransformation
AT dongfeng focusingsensordesignforopenelectricalimpedancetomographybasedonshapeconformaltransformation