Cargando…

Effectiveness Analysis of Systematic Combined Sewer Overflow Control Schemes in the Sponge City Pilot Area of Beijing

Combined sewer overflow (CSO) pollution poses a serious threat to the urban water environment and is more severe in old urban areas. This research uses the old urban area in the sponge city pilot area in Tongzhou District, Beijing, as the study area. The United States Environmental Protection Agency...

Descripción completa

Detalles Bibliográficos
Autores principales: Gong, Yongwei, Chen, Ye, Yu, Lei, Li, Junqi, Pan, Xingyao, Shen, Zhenyao, Xu, Xiang, Qiu, Qianying
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539660/
https://www.ncbi.nlm.nih.gov/pubmed/31035357
http://dx.doi.org/10.3390/ijerph16091503
_version_ 1783422442989944832
author Gong, Yongwei
Chen, Ye
Yu, Lei
Li, Junqi
Pan, Xingyao
Shen, Zhenyao
Xu, Xiang
Qiu, Qianying
author_facet Gong, Yongwei
Chen, Ye
Yu, Lei
Li, Junqi
Pan, Xingyao
Shen, Zhenyao
Xu, Xiang
Qiu, Qianying
author_sort Gong, Yongwei
collection PubMed
description Combined sewer overflow (CSO) pollution poses a serious threat to the urban water environment and is more severe in old urban areas. This research uses the old urban area in the sponge city pilot area in Tongzhou District, Beijing, as the study area. The United States Environmental Protection Agency (USEPA) storm water management model (SWMM) was used to establish the hydrologic and hydraulic model of this area. The model parameters were calibrated and validated based on the measured rainfall and runoff data. The results show that the Nash-Sutcliffe efficiency coefficient for calibration and validation is more than 0.74. Thirty-two sets of systematic CSO control schemes are formulated, which include the "gray (includes the pipes, pumps, ditches, and detention ponds engineered by people to manage stormwater) strategy" and "gray-green strategies", and the regularity of CSO control for "low impact development (LID) facilities at the source", "intercepting sewer pipes at the midway", and "storage tank at the end", are quantitatively analyzed. The results show that the LID facility has an average annual reduction rate of 22% for the CSO frequency and 35% to 49% for the CSO volume. The retrofitting of intercepting sewer pipes has an average annual reduction rate of 11% for the CSO frequency and 4% to 15% for the CSO volume, and the storage tank has an average annual reduction rate from 3% to 36% for the CSO volume; furthermore, the reduction rate decreases with the increase in the CSO volume reduction rate by LID facilities. When the CSO control target is stricter, the control effect of the "end" segment is more obvious, but the control efficiency is lower. By studying the variability of the storage tank volume under different control targets, it can be concluded that it is reasonable to set the CSO control target because the number of overflow events does not exceed four times per year for the study area.
format Online
Article
Text
id pubmed-6539660
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65396602019-06-05 Effectiveness Analysis of Systematic Combined Sewer Overflow Control Schemes in the Sponge City Pilot Area of Beijing Gong, Yongwei Chen, Ye Yu, Lei Li, Junqi Pan, Xingyao Shen, Zhenyao Xu, Xiang Qiu, Qianying Int J Environ Res Public Health Article Combined sewer overflow (CSO) pollution poses a serious threat to the urban water environment and is more severe in old urban areas. This research uses the old urban area in the sponge city pilot area in Tongzhou District, Beijing, as the study area. The United States Environmental Protection Agency (USEPA) storm water management model (SWMM) was used to establish the hydrologic and hydraulic model of this area. The model parameters were calibrated and validated based on the measured rainfall and runoff data. The results show that the Nash-Sutcliffe efficiency coefficient for calibration and validation is more than 0.74. Thirty-two sets of systematic CSO control schemes are formulated, which include the "gray (includes the pipes, pumps, ditches, and detention ponds engineered by people to manage stormwater) strategy" and "gray-green strategies", and the regularity of CSO control for "low impact development (LID) facilities at the source", "intercepting sewer pipes at the midway", and "storage tank at the end", are quantitatively analyzed. The results show that the LID facility has an average annual reduction rate of 22% for the CSO frequency and 35% to 49% for the CSO volume. The retrofitting of intercepting sewer pipes has an average annual reduction rate of 11% for the CSO frequency and 4% to 15% for the CSO volume, and the storage tank has an average annual reduction rate from 3% to 36% for the CSO volume; furthermore, the reduction rate decreases with the increase in the CSO volume reduction rate by LID facilities. When the CSO control target is stricter, the control effect of the "end" segment is more obvious, but the control efficiency is lower. By studying the variability of the storage tank volume under different control targets, it can be concluded that it is reasonable to set the CSO control target because the number of overflow events does not exceed four times per year for the study area. MDPI 2019-04-28 2019-05 /pmc/articles/PMC6539660/ /pubmed/31035357 http://dx.doi.org/10.3390/ijerph16091503 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gong, Yongwei
Chen, Ye
Yu, Lei
Li, Junqi
Pan, Xingyao
Shen, Zhenyao
Xu, Xiang
Qiu, Qianying
Effectiveness Analysis of Systematic Combined Sewer Overflow Control Schemes in the Sponge City Pilot Area of Beijing
title Effectiveness Analysis of Systematic Combined Sewer Overflow Control Schemes in the Sponge City Pilot Area of Beijing
title_full Effectiveness Analysis of Systematic Combined Sewer Overflow Control Schemes in the Sponge City Pilot Area of Beijing
title_fullStr Effectiveness Analysis of Systematic Combined Sewer Overflow Control Schemes in the Sponge City Pilot Area of Beijing
title_full_unstemmed Effectiveness Analysis of Systematic Combined Sewer Overflow Control Schemes in the Sponge City Pilot Area of Beijing
title_short Effectiveness Analysis of Systematic Combined Sewer Overflow Control Schemes in the Sponge City Pilot Area of Beijing
title_sort effectiveness analysis of systematic combined sewer overflow control schemes in the sponge city pilot area of beijing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539660/
https://www.ncbi.nlm.nih.gov/pubmed/31035357
http://dx.doi.org/10.3390/ijerph16091503
work_keys_str_mv AT gongyongwei effectivenessanalysisofsystematiccombinedseweroverflowcontrolschemesinthespongecitypilotareaofbeijing
AT chenye effectivenessanalysisofsystematiccombinedseweroverflowcontrolschemesinthespongecitypilotareaofbeijing
AT yulei effectivenessanalysisofsystematiccombinedseweroverflowcontrolschemesinthespongecitypilotareaofbeijing
AT lijunqi effectivenessanalysisofsystematiccombinedseweroverflowcontrolschemesinthespongecitypilotareaofbeijing
AT panxingyao effectivenessanalysisofsystematiccombinedseweroverflowcontrolschemesinthespongecitypilotareaofbeijing
AT shenzhenyao effectivenessanalysisofsystematiccombinedseweroverflowcontrolschemesinthespongecitypilotareaofbeijing
AT xuxiang effectivenessanalysisofsystematiccombinedseweroverflowcontrolschemesinthespongecitypilotareaofbeijing
AT qiuqianying effectivenessanalysisofsystematiccombinedseweroverflowcontrolschemesinthespongecitypilotareaofbeijing