Cargando…
Development of a fluorescent loop-mediated isothermal amplification assay for rapid and simple diagnosis of bovine leukemia virus infection
Bovine leukemia virus (BLV) causes enzootic bovine leukosis (EBL), a condition that threatens the sustainability of the livestock industry. A fluorescent loop-mediated isothermal amplification (fLAMP) assay targeting BLV env sequences was developed and used to evaluate 100 bovine blood samples. Comp...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society of Veterinary Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6541838/ https://www.ncbi.nlm.nih.gov/pubmed/30918136 http://dx.doi.org/10.1292/jvms.19-0009 |
_version_ | 1783422822911049728 |
---|---|
author | NAGAO, Konomu MAKINO, Ryohei APEGO, Francis Victor MEKATA, Hirohisa YAMAZAKI, Wataru |
author_facet | NAGAO, Konomu MAKINO, Ryohei APEGO, Francis Victor MEKATA, Hirohisa YAMAZAKI, Wataru |
author_sort | NAGAO, Konomu |
collection | PubMed |
description | Bovine leukemia virus (BLV) causes enzootic bovine leukosis (EBL), a condition that threatens the sustainability of the livestock industry. A fluorescent loop-mediated isothermal amplification (fLAMP) assay targeting BLV env sequences was developed and used to evaluate 100 bovine blood samples. Compared with a conventional real-time PCR (rPCR) assay, the fLAMP assay achieved 87.3% (62/71) sensitivity and 100% (29/29) specificity. The rPCR assay took 65 min, while the fLAMP assay took 8 min to 30 min from the beginning of DNA amplification to final judgement with a comparable limit of detection. The fLAMP is a potential tool for the rapid and simple diagnosis of BLV infection to supplement ELISA testing and can be used by local laboratories and slaughterhouses without special equipment. |
format | Online Article Text |
id | pubmed-6541838 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Japanese Society of Veterinary Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-65418382019-06-11 Development of a fluorescent loop-mediated isothermal amplification assay for rapid and simple diagnosis of bovine leukemia virus infection NAGAO, Konomu MAKINO, Ryohei APEGO, Francis Victor MEKATA, Hirohisa YAMAZAKI, Wataru J Vet Med Sci Virology Bovine leukemia virus (BLV) causes enzootic bovine leukosis (EBL), a condition that threatens the sustainability of the livestock industry. A fluorescent loop-mediated isothermal amplification (fLAMP) assay targeting BLV env sequences was developed and used to evaluate 100 bovine blood samples. Compared with a conventional real-time PCR (rPCR) assay, the fLAMP assay achieved 87.3% (62/71) sensitivity and 100% (29/29) specificity. The rPCR assay took 65 min, while the fLAMP assay took 8 min to 30 min from the beginning of DNA amplification to final judgement with a comparable limit of detection. The fLAMP is a potential tool for the rapid and simple diagnosis of BLV infection to supplement ELISA testing and can be used by local laboratories and slaughterhouses without special equipment. The Japanese Society of Veterinary Science 2019-03-27 2019-05 /pmc/articles/PMC6541838/ /pubmed/30918136 http://dx.doi.org/10.1292/jvms.19-0009 Text en ©2019 The Japanese Society of Veterinary Science This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Virology NAGAO, Konomu MAKINO, Ryohei APEGO, Francis Victor MEKATA, Hirohisa YAMAZAKI, Wataru Development of a fluorescent loop-mediated isothermal amplification assay for rapid and simple diagnosis of bovine leukemia virus infection |
title | Development of a fluorescent loop-mediated isothermal amplification assay for rapid and simple diagnosis of bovine leukemia virus infection |
title_full | Development of a fluorescent loop-mediated isothermal amplification assay for rapid and simple diagnosis of bovine leukemia virus infection |
title_fullStr | Development of a fluorescent loop-mediated isothermal amplification assay for rapid and simple diagnosis of bovine leukemia virus infection |
title_full_unstemmed | Development of a fluorescent loop-mediated isothermal amplification assay for rapid and simple diagnosis of bovine leukemia virus infection |
title_short | Development of a fluorescent loop-mediated isothermal amplification assay for rapid and simple diagnosis of bovine leukemia virus infection |
title_sort | development of a fluorescent loop-mediated isothermal amplification assay for rapid and simple diagnosis of bovine leukemia virus infection |
topic | Virology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6541838/ https://www.ncbi.nlm.nih.gov/pubmed/30918136 http://dx.doi.org/10.1292/jvms.19-0009 |
work_keys_str_mv | AT nagaokonomu developmentofafluorescentloopmediatedisothermalamplificationassayforrapidandsimplediagnosisofbovineleukemiavirusinfection AT makinoryohei developmentofafluorescentloopmediatedisothermalamplificationassayforrapidandsimplediagnosisofbovineleukemiavirusinfection AT apegofrancisvictor developmentofafluorescentloopmediatedisothermalamplificationassayforrapidandsimplediagnosisofbovineleukemiavirusinfection AT mekatahirohisa developmentofafluorescentloopmediatedisothermalamplificationassayforrapidandsimplediagnosisofbovineleukemiavirusinfection AT yamazakiwataru developmentofafluorescentloopmediatedisothermalamplificationassayforrapidandsimplediagnosisofbovineleukemiavirusinfection |