Cargando…

Predictive value of gamma-glutamyltransferase for ventricular arrhythmias and cardiovascular mortality in implantable cardioverter-defibrillator patients

BACKGROUND: Gamma-glutamyltransferase (GGT) is a new predictor of cardiovascular diseases. In this study, we aimed to determine its association with ventricular arrhythmias (VAs) in implantable cardioverter-defibrillator (ICD) patients. METHODS: One hundred and forty patients implanted with ICD or c...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, You, Zhao, Shuang, Chen, Keping, Hua, Wei, Zhang, Shu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6542048/
https://www.ncbi.nlm.nih.gov/pubmed/31146684
http://dx.doi.org/10.1186/s12872-019-1114-3
_version_ 1783422868746403840
author Zhou, You
Zhao, Shuang
Chen, Keping
Hua, Wei
Zhang, Shu
author_facet Zhou, You
Zhao, Shuang
Chen, Keping
Hua, Wei
Zhang, Shu
author_sort Zhou, You
collection PubMed
description BACKGROUND: Gamma-glutamyltransferase (GGT) is a new predictor of cardiovascular diseases. In this study, we aimed to determine its association with ventricular arrhythmias (VAs) in implantable cardioverter-defibrillator (ICD) patients. METHODS: One hundred and forty patients implanted with ICD or cardiac resynchronization therapy defibrillator with home monitoring were studied retrospectively. The primary endpoint was appropriate ICD treatment of VAs, secondary endpoint was cardiac death. RESULTS: During a mean follow-up period of 44 ± 17 months, 78 patients (55.7%) experienced VAs, 50 patients (35.7%) were treated with appropriate ICD shocks and 16 patients (11.4%) died due to cardiovascular diseases. GGT was positively correlated with high sensitivity C reactive protein (r = 0.482, P < 0.001), left ventricular end-diastolic dimension (r = 0.175, P = 0.039), New York Heart Association class (r = 0.199, P = 0.018), fasting blood glucose (r = 0.233, P = 0.006) and negatively with left ventricular ejection fraction (r = − 0.181, P = 0.032) and high-density lipoprotein (r = − 0.313, P < 0.001). Based on receiver operating characteristics curve, the cut-off value of GGT = 56 U/L was identified to predict VAs. In Kaplan-Meier survival analysis, GGT ≥56 U/L was associated with increased VAs (P<0.001), ICD shock events (P = 0.006) and cardiovascular mortality (P = 0.003). In multivariate COX regression models, GGT ≥56 U/L was an independent risk factor for VAs (HR 2.253, 95%CI:1.383–3.671, P = 0.001), ICD shocks (HR 2.256, 95%CI:1.219–4.176, P = 0.010) and cardiac death (HR 3.555, 95%CI:1.215–10.404, P = 0.021). CONCLUSIONS: In this ICD population, GGT ≥56 U/L was independently associated with VAs and cardiac death.
format Online
Article
Text
id pubmed-6542048
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-65420482019-06-03 Predictive value of gamma-glutamyltransferase for ventricular arrhythmias and cardiovascular mortality in implantable cardioverter-defibrillator patients Zhou, You Zhao, Shuang Chen, Keping Hua, Wei Zhang, Shu BMC Cardiovasc Disord Research Article BACKGROUND: Gamma-glutamyltransferase (GGT) is a new predictor of cardiovascular diseases. In this study, we aimed to determine its association with ventricular arrhythmias (VAs) in implantable cardioverter-defibrillator (ICD) patients. METHODS: One hundred and forty patients implanted with ICD or cardiac resynchronization therapy defibrillator with home monitoring were studied retrospectively. The primary endpoint was appropriate ICD treatment of VAs, secondary endpoint was cardiac death. RESULTS: During a mean follow-up period of 44 ± 17 months, 78 patients (55.7%) experienced VAs, 50 patients (35.7%) were treated with appropriate ICD shocks and 16 patients (11.4%) died due to cardiovascular diseases. GGT was positively correlated with high sensitivity C reactive protein (r = 0.482, P < 0.001), left ventricular end-diastolic dimension (r = 0.175, P = 0.039), New York Heart Association class (r = 0.199, P = 0.018), fasting blood glucose (r = 0.233, P = 0.006) and negatively with left ventricular ejection fraction (r = − 0.181, P = 0.032) and high-density lipoprotein (r = − 0.313, P < 0.001). Based on receiver operating characteristics curve, the cut-off value of GGT = 56 U/L was identified to predict VAs. In Kaplan-Meier survival analysis, GGT ≥56 U/L was associated with increased VAs (P<0.001), ICD shock events (P = 0.006) and cardiovascular mortality (P = 0.003). In multivariate COX regression models, GGT ≥56 U/L was an independent risk factor for VAs (HR 2.253, 95%CI:1.383–3.671, P = 0.001), ICD shocks (HR 2.256, 95%CI:1.219–4.176, P = 0.010) and cardiac death (HR 3.555, 95%CI:1.215–10.404, P = 0.021). CONCLUSIONS: In this ICD population, GGT ≥56 U/L was independently associated with VAs and cardiac death. BioMed Central 2019-05-30 /pmc/articles/PMC6542048/ /pubmed/31146684 http://dx.doi.org/10.1186/s12872-019-1114-3 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Zhou, You
Zhao, Shuang
Chen, Keping
Hua, Wei
Zhang, Shu
Predictive value of gamma-glutamyltransferase for ventricular arrhythmias and cardiovascular mortality in implantable cardioverter-defibrillator patients
title Predictive value of gamma-glutamyltransferase for ventricular arrhythmias and cardiovascular mortality in implantable cardioverter-defibrillator patients
title_full Predictive value of gamma-glutamyltransferase for ventricular arrhythmias and cardiovascular mortality in implantable cardioverter-defibrillator patients
title_fullStr Predictive value of gamma-glutamyltransferase for ventricular arrhythmias and cardiovascular mortality in implantable cardioverter-defibrillator patients
title_full_unstemmed Predictive value of gamma-glutamyltransferase for ventricular arrhythmias and cardiovascular mortality in implantable cardioverter-defibrillator patients
title_short Predictive value of gamma-glutamyltransferase for ventricular arrhythmias and cardiovascular mortality in implantable cardioverter-defibrillator patients
title_sort predictive value of gamma-glutamyltransferase for ventricular arrhythmias and cardiovascular mortality in implantable cardioverter-defibrillator patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6542048/
https://www.ncbi.nlm.nih.gov/pubmed/31146684
http://dx.doi.org/10.1186/s12872-019-1114-3
work_keys_str_mv AT zhouyou predictivevalueofgammaglutamyltransferaseforventriculararrhythmiasandcardiovascularmortalityinimplantablecardioverterdefibrillatorpatients
AT zhaoshuang predictivevalueofgammaglutamyltransferaseforventriculararrhythmiasandcardiovascularmortalityinimplantablecardioverterdefibrillatorpatients
AT chenkeping predictivevalueofgammaglutamyltransferaseforventriculararrhythmiasandcardiovascularmortalityinimplantablecardioverterdefibrillatorpatients
AT huawei predictivevalueofgammaglutamyltransferaseforventriculararrhythmiasandcardiovascularmortalityinimplantablecardioverterdefibrillatorpatients
AT zhangshu predictivevalueofgammaglutamyltransferaseforventriculararrhythmiasandcardiovascularmortalityinimplantablecardioverterdefibrillatorpatients