Health costs and efficiencies of patient-specific and single-use instrumentation in total knee arthroplasty: a randomised controlled trial
AIM: To investigate whether patient-specific instrumentation (PSI) and single-use instrumentation (SUI) improve operating room efficiency in terms of time and cost to the healthcare provider over conventional/reusable instrumentation (CVR) when performing total knee arthroplasty (TKA). PATIENTS AND...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6542447/ https://www.ncbi.nlm.nih.gov/pubmed/31206056 http://dx.doi.org/10.1136/bmjoq-2018-000493 |
_version_ | 1783422937547669504 |
---|---|
author | Attard, Andre Tawy, Gwenllian Fflur Simons, Michiel Riches, Philip Rowe, Philip Biant, Leela C |
author_facet | Attard, Andre Tawy, Gwenllian Fflur Simons, Michiel Riches, Philip Rowe, Philip Biant, Leela C |
author_sort | Attard, Andre |
collection | PubMed |
description | AIM: To investigate whether patient-specific instrumentation (PSI) and single-use instrumentation (SUI) improve operating room efficiency in terms of time and cost to the healthcare provider over conventional/reusable instrumentation (CVR) when performing total knee arthroplasty (TKA). PATIENTS AND METHODS: Patients requiring TKA were randomised into one of four surgical groups: CVR, CVS (conventional/SUI), PSR (PSI/reusable) and PSS (PSI/SUI). All surgical procedures were video recorded to determine specific surgical time intervals. Other variables reported included the number of instrument trays used, missing equipment, direct instrument costs and the weight of the instruments the staff had to handle. Oxford Knee Score (OKS), estimated blood loss and lengths of hospital stay were also recorded as markers of patient experience. RESULTS: PSR was significantly quicker in all the recorded time intervals, used less trays, experienced less missing equipment and resulted in lower blood loss and shorter hospital stays. SUI reported significantly slower operating room times and resulted in higher blood loss, but SUI was 88% lighter and 20% cheaper on average when compared with their reusable counterparts. Despite the economic advantages of PSI and SUI, the patients who reported greatest improvements in OKS were those allocated to the CVR group, but no clinically meaningful difference in OKS was found at any time point. CONCLUSIONS: PSI and SUI for TKA have the potential of reducing operating room times over conventional, reusable sets. This reduction will benefit theatre personnel ergonomically, while presenting the healthcare provider with potential cost-saving benefits in terms of reduced sterilisation costs and surgical times. |
format | Online Article Text |
id | pubmed-6542447 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-65424472019-06-14 Health costs and efficiencies of patient-specific and single-use instrumentation in total knee arthroplasty: a randomised controlled trial Attard, Andre Tawy, Gwenllian Fflur Simons, Michiel Riches, Philip Rowe, Philip Biant, Leela C BMJ Open Qual Original Article AIM: To investigate whether patient-specific instrumentation (PSI) and single-use instrumentation (SUI) improve operating room efficiency in terms of time and cost to the healthcare provider over conventional/reusable instrumentation (CVR) when performing total knee arthroplasty (TKA). PATIENTS AND METHODS: Patients requiring TKA were randomised into one of four surgical groups: CVR, CVS (conventional/SUI), PSR (PSI/reusable) and PSS (PSI/SUI). All surgical procedures were video recorded to determine specific surgical time intervals. Other variables reported included the number of instrument trays used, missing equipment, direct instrument costs and the weight of the instruments the staff had to handle. Oxford Knee Score (OKS), estimated blood loss and lengths of hospital stay were also recorded as markers of patient experience. RESULTS: PSR was significantly quicker in all the recorded time intervals, used less trays, experienced less missing equipment and resulted in lower blood loss and shorter hospital stays. SUI reported significantly slower operating room times and resulted in higher blood loss, but SUI was 88% lighter and 20% cheaper on average when compared with their reusable counterparts. Despite the economic advantages of PSI and SUI, the patients who reported greatest improvements in OKS were those allocated to the CVR group, but no clinically meaningful difference in OKS was found at any time point. CONCLUSIONS: PSI and SUI for TKA have the potential of reducing operating room times over conventional, reusable sets. This reduction will benefit theatre personnel ergonomically, while presenting the healthcare provider with potential cost-saving benefits in terms of reduced sterilisation costs and surgical times. BMJ Publishing Group 2019-05-29 /pmc/articles/PMC6542447/ /pubmed/31206056 http://dx.doi.org/10.1136/bmjoq-2018-000493 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Original Article Attard, Andre Tawy, Gwenllian Fflur Simons, Michiel Riches, Philip Rowe, Philip Biant, Leela C Health costs and efficiencies of patient-specific and single-use instrumentation in total knee arthroplasty: a randomised controlled trial |
title | Health costs and efficiencies of patient-specific and single-use instrumentation in total knee arthroplasty: a randomised controlled trial |
title_full | Health costs and efficiencies of patient-specific and single-use instrumentation in total knee arthroplasty: a randomised controlled trial |
title_fullStr | Health costs and efficiencies of patient-specific and single-use instrumentation in total knee arthroplasty: a randomised controlled trial |
title_full_unstemmed | Health costs and efficiencies of patient-specific and single-use instrumentation in total knee arthroplasty: a randomised controlled trial |
title_short | Health costs and efficiencies of patient-specific and single-use instrumentation in total knee arthroplasty: a randomised controlled trial |
title_sort | health costs and efficiencies of patient-specific and single-use instrumentation in total knee arthroplasty: a randomised controlled trial |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6542447/ https://www.ncbi.nlm.nih.gov/pubmed/31206056 http://dx.doi.org/10.1136/bmjoq-2018-000493 |
work_keys_str_mv | AT attardandre healthcostsandefficienciesofpatientspecificandsingleuseinstrumentationintotalkneearthroplastyarandomisedcontrolledtrial AT tawygwenllianfflur healthcostsandefficienciesofpatientspecificandsingleuseinstrumentationintotalkneearthroplastyarandomisedcontrolledtrial AT simonsmichiel healthcostsandefficienciesofpatientspecificandsingleuseinstrumentationintotalkneearthroplastyarandomisedcontrolledtrial AT richesphilip healthcostsandefficienciesofpatientspecificandsingleuseinstrumentationintotalkneearthroplastyarandomisedcontrolledtrial AT rowephilip healthcostsandefficienciesofpatientspecificandsingleuseinstrumentationintotalkneearthroplastyarandomisedcontrolledtrial AT biantleelac healthcostsandefficienciesofpatientspecificandsingleuseinstrumentationintotalkneearthroplastyarandomisedcontrolledtrial |