Cargando…
Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation
PURPOSE: To evaluate the clinico-radiological outcome of complex tibial plateau fractures treated with Ilizarov external fixation with or without minimal internal fixation. METHODS: This retrospective review was conducted on all the cases of Schatzker types V and VI tibial plateau fractures treated...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6543267/ https://www.ncbi.nlm.nih.gov/pubmed/31072699 http://dx.doi.org/10.1016/j.cjtee.2018.11.003 |
_version_ | 1783423076012130304 |
---|---|
author | Subramanyam, Koushik Narayan Tammanaiah, Madhusudhan Mundargi, Abhishek Vasant Bhoskar, Ritesh Nilakanthrao Reddy, Patllola Siddharth |
author_facet | Subramanyam, Koushik Narayan Tammanaiah, Madhusudhan Mundargi, Abhishek Vasant Bhoskar, Ritesh Nilakanthrao Reddy, Patllola Siddharth |
author_sort | Subramanyam, Koushik Narayan |
collection | PubMed |
description | PURPOSE: To evaluate the clinico-radiological outcome of complex tibial plateau fractures treated with Ilizarov external fixation with or without minimal internal fixation. METHODS: This retrospective review was conducted on all the cases of Schatzker types V and VI tibial plateau fractures treated by Ilizarov external fixation between July 2006 and December 2015 with the minimum follow-up duration of one year. There were 30 patients: 24 males and 6 females, mean age 43.33 years, and mean follow-up 3.6 years. Three of them were open fractures; 15 cases were Schatzkertype V fractures and the other 15 type VI. According to AO/OTA classification, there were 11 type C1, 12 C2 and 7 type C3 fractures. Outcome assessment was made with American Knee Society Score (AKSS) and Rasmussen's Radiological Score (RRS) at final follow-up. RESULTS: Out of the 30 cases, mini-open reduction was performed in 7, bone graft in 4, minimal internal fixation in 10 and knee temporary immobilisation in 11 patients. Mean duration of external fixation was 11.8 weeks. All fractures united. Pin tract infections in 7 and common peroneal neuropathy in 2 patients were self-limiting. Two patients had axial misalignment of less than 10°. At final follow-up, the mean knee range of motion was 114.7, mean AKSS 81.5 and mean RRS 16.7. On statistical analysis, Schatzker type of fractures, use of minimal internal fixation and knee-spanning did not influence the final outcome. CONCLUSION: Ilizarov external fixator with or without minimal internal fixation provides acceptable outcome for complex tibial plateau fractures. Care must be taken to look for minor loss of alignment, especially in Type VI Schatzker fractures after removal of the fixator. However small sample size precludes firm conclusions. |
format | Online Article Text |
id | pubmed-6543267 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-65432672019-06-04 Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation Subramanyam, Koushik Narayan Tammanaiah, Madhusudhan Mundargi, Abhishek Vasant Bhoskar, Ritesh Nilakanthrao Reddy, Patllola Siddharth Chin J Traumatol Original Article PURPOSE: To evaluate the clinico-radiological outcome of complex tibial plateau fractures treated with Ilizarov external fixation with or without minimal internal fixation. METHODS: This retrospective review was conducted on all the cases of Schatzker types V and VI tibial plateau fractures treated by Ilizarov external fixation between July 2006 and December 2015 with the minimum follow-up duration of one year. There were 30 patients: 24 males and 6 females, mean age 43.33 years, and mean follow-up 3.6 years. Three of them were open fractures; 15 cases were Schatzkertype V fractures and the other 15 type VI. According to AO/OTA classification, there were 11 type C1, 12 C2 and 7 type C3 fractures. Outcome assessment was made with American Knee Society Score (AKSS) and Rasmussen's Radiological Score (RRS) at final follow-up. RESULTS: Out of the 30 cases, mini-open reduction was performed in 7, bone graft in 4, minimal internal fixation in 10 and knee temporary immobilisation in 11 patients. Mean duration of external fixation was 11.8 weeks. All fractures united. Pin tract infections in 7 and common peroneal neuropathy in 2 patients were self-limiting. Two patients had axial misalignment of less than 10°. At final follow-up, the mean knee range of motion was 114.7, mean AKSS 81.5 and mean RRS 16.7. On statistical analysis, Schatzker type of fractures, use of minimal internal fixation and knee-spanning did not influence the final outcome. CONCLUSION: Ilizarov external fixator with or without minimal internal fixation provides acceptable outcome for complex tibial plateau fractures. Care must be taken to look for minor loss of alignment, especially in Type VI Schatzker fractures after removal of the fixator. However small sample size precludes firm conclusions. Elsevier 2019-06 2019-04-13 /pmc/articles/PMC6543267/ /pubmed/31072699 http://dx.doi.org/10.1016/j.cjtee.2018.11.003 Text en © 2019 Chinese Medical Association. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Subramanyam, Koushik Narayan Tammanaiah, Madhusudhan Mundargi, Abhishek Vasant Bhoskar, Ritesh Nilakanthrao Reddy, Patllola Siddharth Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation |
title | Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation |
title_full | Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation |
title_fullStr | Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation |
title_full_unstemmed | Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation |
title_short | Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation |
title_sort | outcome of complex tibial plateau fractures with ilizarov external fixation with or without minimal internal fixation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6543267/ https://www.ncbi.nlm.nih.gov/pubmed/31072699 http://dx.doi.org/10.1016/j.cjtee.2018.11.003 |
work_keys_str_mv | AT subramanyamkoushiknarayan outcomeofcomplextibialplateaufractureswithilizarovexternalfixationwithorwithoutminimalinternalfixation AT tammanaiahmadhusudhan outcomeofcomplextibialplateaufractureswithilizarovexternalfixationwithorwithoutminimalinternalfixation AT mundargiabhishekvasant outcomeofcomplextibialplateaufractureswithilizarovexternalfixationwithorwithoutminimalinternalfixation AT bhoskarriteshnilakanthrao outcomeofcomplextibialplateaufractureswithilizarovexternalfixationwithorwithoutminimalinternalfixation AT reddypatllolasiddharth outcomeofcomplextibialplateaufractureswithilizarovexternalfixationwithorwithoutminimalinternalfixation |