Pooled Analysis of the Efficacy and Safety of Video Capsule Endoscopy in Patients with Implantable Cardiac Devices

BACKGROUND: To date, video capsule endoscopy (VCE) is still contraindicated by the FDA and the main manufacturers of Cardiac Implantable Electronic Devices (CIED) in patients with CIED, given a theoretical electromagnetic interference and possible device malfunction. OBJECTIVES: The objective of thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Tabet, Rabih, Nassani, Najib, Karam, Boutros, Shammaa, Youssef, Akhrass, Philippe, Deeb, Liliane
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6545804/
https://www.ncbi.nlm.nih.gov/pubmed/31236386
http://dx.doi.org/10.1155/2019/3953807
_version_ 1783423450376830976
author Tabet, Rabih
Nassani, Najib
Karam, Boutros
Shammaa, Youssef
Akhrass, Philippe
Deeb, Liliane
author_facet Tabet, Rabih
Nassani, Najib
Karam, Boutros
Shammaa, Youssef
Akhrass, Philippe
Deeb, Liliane
author_sort Tabet, Rabih
collection PubMed
description BACKGROUND: To date, video capsule endoscopy (VCE) is still contraindicated by the FDA and the main manufacturers of Cardiac Implantable Electronic Devices (CIED) in patients with CIED, given a theoretical electromagnetic interference and possible device malfunction. OBJECTIVES: The objective of this study was to assess the safety profile and efficacy of VCE in patients with implantable cardiac devices through analyzing the risk of mutual interference. METHODS: A systematic review of PubMed, Web of Science, and Embase databases was conducted. Peer-reviewed original articles, published in the English language and containing “capsule endoscopy” AND “pacemaker”, “defibrillator” OR “left ventricular assist device” as keywords, were selected. Studies performed in vitro, isolated case reports, and abstracts/posters were excluded. RESULTS: A total of 735 VCE procedures were performed in patients with cardiac devices in various clinical settings. Cardiac events were not seen in any case. Interference on capsule images transmission was noted in 5 cases (left ventricular assist device (LVAD)) where few images were lost when the capsule was closest to the device. Finally, interference between capsule and telemetry leads was noted in 6 cases (4 Permanent Pacemakers (PPM), 2 Implantable Cardioverter-Defibrillator (ICD)) leading to image artifacts. DISCUSSION: Adverse cardiac events were not seen in any study. Loss of images occurred when the VCE was in proximity to the device (only with LVAD) or after telemetry leads installation without affecting the completion rate and diagnostic yield of VCE. CONCLUSION: VCE is safe and remains efficient in patients with cardiac devices. If cardiac monitoring is required, wired systems are preferable.
format Online
Article
Text
id pubmed-6545804
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-65458042019-06-24 Pooled Analysis of the Efficacy and Safety of Video Capsule Endoscopy in Patients with Implantable Cardiac Devices Tabet, Rabih Nassani, Najib Karam, Boutros Shammaa, Youssef Akhrass, Philippe Deeb, Liliane Can J Gastroenterol Hepatol Review Article BACKGROUND: To date, video capsule endoscopy (VCE) is still contraindicated by the FDA and the main manufacturers of Cardiac Implantable Electronic Devices (CIED) in patients with CIED, given a theoretical electromagnetic interference and possible device malfunction. OBJECTIVES: The objective of this study was to assess the safety profile and efficacy of VCE in patients with implantable cardiac devices through analyzing the risk of mutual interference. METHODS: A systematic review of PubMed, Web of Science, and Embase databases was conducted. Peer-reviewed original articles, published in the English language and containing “capsule endoscopy” AND “pacemaker”, “defibrillator” OR “left ventricular assist device” as keywords, were selected. Studies performed in vitro, isolated case reports, and abstracts/posters were excluded. RESULTS: A total of 735 VCE procedures were performed in patients with cardiac devices in various clinical settings. Cardiac events were not seen in any case. Interference on capsule images transmission was noted in 5 cases (left ventricular assist device (LVAD)) where few images were lost when the capsule was closest to the device. Finally, interference between capsule and telemetry leads was noted in 6 cases (4 Permanent Pacemakers (PPM), 2 Implantable Cardioverter-Defibrillator (ICD)) leading to image artifacts. DISCUSSION: Adverse cardiac events were not seen in any study. Loss of images occurred when the VCE was in proximity to the device (only with LVAD) or after telemetry leads installation without affecting the completion rate and diagnostic yield of VCE. CONCLUSION: VCE is safe and remains efficient in patients with cardiac devices. If cardiac monitoring is required, wired systems are preferable. Hindawi 2019-05-19 /pmc/articles/PMC6545804/ /pubmed/31236386 http://dx.doi.org/10.1155/2019/3953807 Text en Copyright © 2019 Rabih Tabet et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Tabet, Rabih
Nassani, Najib
Karam, Boutros
Shammaa, Youssef
Akhrass, Philippe
Deeb, Liliane
Pooled Analysis of the Efficacy and Safety of Video Capsule Endoscopy in Patients with Implantable Cardiac Devices
title Pooled Analysis of the Efficacy and Safety of Video Capsule Endoscopy in Patients with Implantable Cardiac Devices
title_full Pooled Analysis of the Efficacy and Safety of Video Capsule Endoscopy in Patients with Implantable Cardiac Devices
title_fullStr Pooled Analysis of the Efficacy and Safety of Video Capsule Endoscopy in Patients with Implantable Cardiac Devices
title_full_unstemmed Pooled Analysis of the Efficacy and Safety of Video Capsule Endoscopy in Patients with Implantable Cardiac Devices
title_short Pooled Analysis of the Efficacy and Safety of Video Capsule Endoscopy in Patients with Implantable Cardiac Devices
title_sort pooled analysis of the efficacy and safety of video capsule endoscopy in patients with implantable cardiac devices
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6545804/
https://www.ncbi.nlm.nih.gov/pubmed/31236386
http://dx.doi.org/10.1155/2019/3953807
work_keys_str_mv AT tabetrabih pooledanalysisoftheefficacyandsafetyofvideocapsuleendoscopyinpatientswithimplantablecardiacdevices
AT nassaninajib pooledanalysisoftheefficacyandsafetyofvideocapsuleendoscopyinpatientswithimplantablecardiacdevices
AT karamboutros pooledanalysisoftheefficacyandsafetyofvideocapsuleendoscopyinpatientswithimplantablecardiacdevices
AT shammaayoussef pooledanalysisoftheefficacyandsafetyofvideocapsuleendoscopyinpatientswithimplantablecardiacdevices
AT akhrassphilippe pooledanalysisoftheefficacyandsafetyofvideocapsuleendoscopyinpatientswithimplantablecardiacdevices
AT deebliliane pooledanalysisoftheefficacyandsafetyofvideocapsuleendoscopyinpatientswithimplantablecardiacdevices