Cargando…

A validation study of the Eurostat harmonised European time use study (HETUS) diary using wearable technology

BACKGROUND: The central aim was to examine the accuracy of the full range of daily activities recorded in self-report time-use diaries against data from two objective passive data collection devices (wearable camera and accelerometer) serving as criterion reference instruments. This enabled systemat...

Descripción completa

Detalles Bibliográficos
Autores principales: Harms, Teresa, Gershuny, Jonathan, Doherty, Aiden, Thomas, Emma, Milton, Karen, Foster, Charlie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6546612/
https://www.ncbi.nlm.nih.gov/pubmed/31159770
http://dx.doi.org/10.1186/s12889-019-6761-x
_version_ 1783423540909834240
author Harms, Teresa
Gershuny, Jonathan
Doherty, Aiden
Thomas, Emma
Milton, Karen
Foster, Charlie
author_facet Harms, Teresa
Gershuny, Jonathan
Doherty, Aiden
Thomas, Emma
Milton, Karen
Foster, Charlie
author_sort Harms, Teresa
collection PubMed
description BACKGROUND: The central aim was to examine the accuracy of the full range of daily activities recorded in self-report time-use diaries against data from two objective passive data collection devices (wearable camera and accelerometer) serving as criterion reference instruments. This enabled systematic checks and comparisons on the timing, sequence and duration of activities recorded from the three data sources. METHODS: Participants (n = 148) were asked to complete a single-day self-report paper time-use diary designed for use in the Harmonised European Time Use Study (HETUS), while simultaneously wearing a camera that continuously recorded images of their activities, and an accelerometer tracking physical movement. In a reconstruction interview shortly after the data collection period, participants viewed the camera images to help researchers interpret the image sequences. Of the initial 148 recruits (multi-seed snowball sample, 59% women, aged 18–91, 43% > 40) 131 returned usable diary and camera records (of whom 124 also provided a usable whole-day accelerometer record. We compare time allocation estimates from the diary and camera records, and also match the diary and camera records to the simultaneously recorded accelerometer vector magnitudes. RESULTS: The data were examined at three analytic levels: aggregate, individual diarist and timeslot. The most important finding is that the estimates of mean daily time devoted to 8 of the 10 main activities differ by < 10% in the camera and diary records. The single case of major divergence (eating) can be explained by a systematic difference between the procedures followed by the self-reporting diarist and the observer coding the camera records. There are more substantial differences at the respondent level, paired t-tests showing significant differences in time spent in the 4/10 categories. 45% of all variation in the accelerometer vector magnitudes in the timeslots is explained by camera and diary records. Detailed activity classifications perform much better than METs as predictors of actigraphy. CONCLUSIONS: The comparison of the diary with the camera and accelerometer records strongly supports using diary methodology for studying the full range of daily activity, particularly at aggregate levels. Accelerometer data could be combined with diary measures to improve estimation of METs equivalents for various types of active and sedentary behaviour.
format Online
Article
Text
id pubmed-6546612
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-65466122019-06-06 A validation study of the Eurostat harmonised European time use study (HETUS) diary using wearable technology Harms, Teresa Gershuny, Jonathan Doherty, Aiden Thomas, Emma Milton, Karen Foster, Charlie BMC Public Health Research BACKGROUND: The central aim was to examine the accuracy of the full range of daily activities recorded in self-report time-use diaries against data from two objective passive data collection devices (wearable camera and accelerometer) serving as criterion reference instruments. This enabled systematic checks and comparisons on the timing, sequence and duration of activities recorded from the three data sources. METHODS: Participants (n = 148) were asked to complete a single-day self-report paper time-use diary designed for use in the Harmonised European Time Use Study (HETUS), while simultaneously wearing a camera that continuously recorded images of their activities, and an accelerometer tracking physical movement. In a reconstruction interview shortly after the data collection period, participants viewed the camera images to help researchers interpret the image sequences. Of the initial 148 recruits (multi-seed snowball sample, 59% women, aged 18–91, 43% > 40) 131 returned usable diary and camera records (of whom 124 also provided a usable whole-day accelerometer record. We compare time allocation estimates from the diary and camera records, and also match the diary and camera records to the simultaneously recorded accelerometer vector magnitudes. RESULTS: The data were examined at three analytic levels: aggregate, individual diarist and timeslot. The most important finding is that the estimates of mean daily time devoted to 8 of the 10 main activities differ by < 10% in the camera and diary records. The single case of major divergence (eating) can be explained by a systematic difference between the procedures followed by the self-reporting diarist and the observer coding the camera records. There are more substantial differences at the respondent level, paired t-tests showing significant differences in time spent in the 4/10 categories. 45% of all variation in the accelerometer vector magnitudes in the timeslots is explained by camera and diary records. Detailed activity classifications perform much better than METs as predictors of actigraphy. CONCLUSIONS: The comparison of the diary with the camera and accelerometer records strongly supports using diary methodology for studying the full range of daily activity, particularly at aggregate levels. Accelerometer data could be combined with diary measures to improve estimation of METs equivalents for various types of active and sedentary behaviour. BioMed Central 2019-06-03 /pmc/articles/PMC6546612/ /pubmed/31159770 http://dx.doi.org/10.1186/s12889-019-6761-x Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Harms, Teresa
Gershuny, Jonathan
Doherty, Aiden
Thomas, Emma
Milton, Karen
Foster, Charlie
A validation study of the Eurostat harmonised European time use study (HETUS) diary using wearable technology
title A validation study of the Eurostat harmonised European time use study (HETUS) diary using wearable technology
title_full A validation study of the Eurostat harmonised European time use study (HETUS) diary using wearable technology
title_fullStr A validation study of the Eurostat harmonised European time use study (HETUS) diary using wearable technology
title_full_unstemmed A validation study of the Eurostat harmonised European time use study (HETUS) diary using wearable technology
title_short A validation study of the Eurostat harmonised European time use study (HETUS) diary using wearable technology
title_sort validation study of the eurostat harmonised european time use study (hetus) diary using wearable technology
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6546612/
https://www.ncbi.nlm.nih.gov/pubmed/31159770
http://dx.doi.org/10.1186/s12889-019-6761-x
work_keys_str_mv AT harmsteresa avalidationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT gershunyjonathan avalidationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT dohertyaiden avalidationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT thomasemma avalidationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT miltonkaren avalidationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT fostercharlie avalidationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT harmsteresa validationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT gershunyjonathan validationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT dohertyaiden validationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT thomasemma validationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT miltonkaren validationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology
AT fostercharlie validationstudyoftheeurostatharmonisedeuropeantimeusestudyhetusdiaryusingwearabletechnology