Hair Cortisol Measurement by an Automated Method
We present the development of the first procedure for hair cortisol measurement through an automated method. Hair samples were obtained from 286 individuals. After cortisol extraction, samples were measured in a Siemens Immulite 2000 (Gwynedd, UK) automated chemoluminiscent immunoassay analyzer. Nor...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6546685/ https://www.ncbi.nlm.nih.gov/pubmed/31160639 http://dx.doi.org/10.1038/s41598-019-44693-3 |
_version_ | 1783423553580826624 |
---|---|
author | Gonzalez, Diego Jacobsen, Dario Ibar, Carolina Pavan, Carlos Monti, José Fernandez Machulsky, Nahuel Balbi, Ayelen Fritzler, Analy Jamardo, Juan Repetto, Esteban M. Berg, Gabriela Fabre, Bibiana |
author_facet | Gonzalez, Diego Jacobsen, Dario Ibar, Carolina Pavan, Carlos Monti, José Fernandez Machulsky, Nahuel Balbi, Ayelen Fritzler, Analy Jamardo, Juan Repetto, Esteban M. Berg, Gabriela Fabre, Bibiana |
author_sort | Gonzalez, Diego |
collection | PubMed |
description | We present the development of the first procedure for hair cortisol measurement through an automated method. Hair samples were obtained from 286 individuals. After cortisol extraction, samples were measured in a Siemens Immulite 2000 (Gwynedd, UK) automated chemoluminiscent immunoassay analyzer. Normal reference values were obtained from hair cortisol levels measured in 213 healthy individuals with low levels of stress. Hair cortisol concentration median was 55 pg/mg hair (2.5–97.5 percentile (40–128)) in healthy individuals with low levels of stress and 250 pg/mg hair (range 182–520) in stressed individuals. No significant differences were observed in hair cortisol levels between subjects with and without dye (40 (40–107) and 40 (40–155) pg/mg hair, respectively; p = 0.128). The novel procedure presented here shows an adequate analytical performance. |
format | Online Article Text |
id | pubmed-6546685 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-65466852019-06-10 Hair Cortisol Measurement by an Automated Method Gonzalez, Diego Jacobsen, Dario Ibar, Carolina Pavan, Carlos Monti, José Fernandez Machulsky, Nahuel Balbi, Ayelen Fritzler, Analy Jamardo, Juan Repetto, Esteban M. Berg, Gabriela Fabre, Bibiana Sci Rep Article We present the development of the first procedure for hair cortisol measurement through an automated method. Hair samples were obtained from 286 individuals. After cortisol extraction, samples were measured in a Siemens Immulite 2000 (Gwynedd, UK) automated chemoluminiscent immunoassay analyzer. Normal reference values were obtained from hair cortisol levels measured in 213 healthy individuals with low levels of stress. Hair cortisol concentration median was 55 pg/mg hair (2.5–97.5 percentile (40–128)) in healthy individuals with low levels of stress and 250 pg/mg hair (range 182–520) in stressed individuals. No significant differences were observed in hair cortisol levels between subjects with and without dye (40 (40–107) and 40 (40–155) pg/mg hair, respectively; p = 0.128). The novel procedure presented here shows an adequate analytical performance. Nature Publishing Group UK 2019-06-03 /pmc/articles/PMC6546685/ /pubmed/31160639 http://dx.doi.org/10.1038/s41598-019-44693-3 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Gonzalez, Diego Jacobsen, Dario Ibar, Carolina Pavan, Carlos Monti, José Fernandez Machulsky, Nahuel Balbi, Ayelen Fritzler, Analy Jamardo, Juan Repetto, Esteban M. Berg, Gabriela Fabre, Bibiana Hair Cortisol Measurement by an Automated Method |
title | Hair Cortisol Measurement by an Automated Method |
title_full | Hair Cortisol Measurement by an Automated Method |
title_fullStr | Hair Cortisol Measurement by an Automated Method |
title_full_unstemmed | Hair Cortisol Measurement by an Automated Method |
title_short | Hair Cortisol Measurement by an Automated Method |
title_sort | hair cortisol measurement by an automated method |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6546685/ https://www.ncbi.nlm.nih.gov/pubmed/31160639 http://dx.doi.org/10.1038/s41598-019-44693-3 |
work_keys_str_mv | AT gonzalezdiego haircortisolmeasurementbyanautomatedmethod AT jacobsendario haircortisolmeasurementbyanautomatedmethod AT ibarcarolina haircortisolmeasurementbyanautomatedmethod AT pavancarlos haircortisolmeasurementbyanautomatedmethod AT montijose haircortisolmeasurementbyanautomatedmethod AT fernandezmachulskynahuel haircortisolmeasurementbyanautomatedmethod AT balbiayelen haircortisolmeasurementbyanautomatedmethod AT fritzleranaly haircortisolmeasurementbyanautomatedmethod AT jamardojuan haircortisolmeasurementbyanautomatedmethod AT repettoestebanm haircortisolmeasurementbyanautomatedmethod AT berggabriela haircortisolmeasurementbyanautomatedmethod AT fabrebibiana haircortisolmeasurementbyanautomatedmethod |