Cargando…

Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement

Rupture of a pseudoaneurysm (PA) has been reported as a rare but serious adverse event associated with endoscopic biliary stenting. We herein report 2 cases of severe biliary bleeding from a PA that developed 10-14 days after placement of a self-expandable metallic stent (SEMS) for biliary malignanc...

Descripción completa

Detalles Bibliográficos
Autores principales: Satoh, Tatsunori, Matsubayashi, Hiroyuki, Ishiwatari, Hirotoshi, Fujie, Shinya, Kaneko, Junichi, Sato, Junya, Ito, Sayo, Kishida, Yoshihiro, Imai, Kenichiro, Hotta, Kinichi, Yoshida, Masao, Kawata, Noboru, Takizawa, Kohei, Kakushima, Naomi, Sawada, Akihiro, Ono, Hiroyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society of Internal Medicine 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6548938/
https://www.ncbi.nlm.nih.gov/pubmed/30626807
http://dx.doi.org/10.2169/internalmedicine.1862-18
_version_ 1783423903873368064
author Satoh, Tatsunori
Matsubayashi, Hiroyuki
Ishiwatari, Hirotoshi
Fujie, Shinya
Kaneko, Junichi
Sato, Junya
Ito, Sayo
Kishida, Yoshihiro
Imai, Kenichiro
Hotta, Kinichi
Yoshida, Masao
Kawata, Noboru
Takizawa, Kohei
Kakushima, Naomi
Sawada, Akihiro
Ono, Hiroyuki
author_facet Satoh, Tatsunori
Matsubayashi, Hiroyuki
Ishiwatari, Hirotoshi
Fujie, Shinya
Kaneko, Junichi
Sato, Junya
Ito, Sayo
Kishida, Yoshihiro
Imai, Kenichiro
Hotta, Kinichi
Yoshida, Masao
Kawata, Noboru
Takizawa, Kohei
Kakushima, Naomi
Sawada, Akihiro
Ono, Hiroyuki
author_sort Satoh, Tatsunori
collection PubMed
description Rupture of a pseudoaneurysm (PA) has been reported as a rare but serious adverse event associated with endoscopic biliary stenting. We herein report 2 cases of severe biliary bleeding from a PA that developed 10-14 days after placement of a self-expandable metallic stent (SEMS) for biliary malignancy. The first patient was successfully embolized with endovascular coiling. However, the second patient had wide-spreading cholangiocarcinoma and, despite being treated once by full coiling, developed a second rupture of PA two months after starting systemic chemotherapy. Clinicians should be aware of the possibility of PA and carefully follow stented patients after endovascular treatment.
format Online
Article
Text
id pubmed-6548938
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Japanese Society of Internal Medicine
record_format MEDLINE/PubMed
spelling pubmed-65489382019-06-17 Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement Satoh, Tatsunori Matsubayashi, Hiroyuki Ishiwatari, Hirotoshi Fujie, Shinya Kaneko, Junichi Sato, Junya Ito, Sayo Kishida, Yoshihiro Imai, Kenichiro Hotta, Kinichi Yoshida, Masao Kawata, Noboru Takizawa, Kohei Kakushima, Naomi Sawada, Akihiro Ono, Hiroyuki Intern Med Case Report Rupture of a pseudoaneurysm (PA) has been reported as a rare but serious adverse event associated with endoscopic biliary stenting. We herein report 2 cases of severe biliary bleeding from a PA that developed 10-14 days after placement of a self-expandable metallic stent (SEMS) for biliary malignancy. The first patient was successfully embolized with endovascular coiling. However, the second patient had wide-spreading cholangiocarcinoma and, despite being treated once by full coiling, developed a second rupture of PA two months after starting systemic chemotherapy. Clinicians should be aware of the possibility of PA and carefully follow stented patients after endovascular treatment. The Japanese Society of Internal Medicine 2019-01-10 2019-05-15 /pmc/articles/PMC6548938/ /pubmed/30626807 http://dx.doi.org/10.2169/internalmedicine.1862-18 Text en Copyright © 2019 by The Japanese Society of Internal Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/ The Internal Medicine is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Satoh, Tatsunori
Matsubayashi, Hiroyuki
Ishiwatari, Hirotoshi
Fujie, Shinya
Kaneko, Junichi
Sato, Junya
Ito, Sayo
Kishida, Yoshihiro
Imai, Kenichiro
Hotta, Kinichi
Yoshida, Masao
Kawata, Noboru
Takizawa, Kohei
Kakushima, Naomi
Sawada, Akihiro
Ono, Hiroyuki
Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement
title Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement
title_full Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement
title_fullStr Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement
title_full_unstemmed Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement
title_short Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement
title_sort rupture of pseudoaneurysm after biliary metallic stent placement
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6548938/
https://www.ncbi.nlm.nih.gov/pubmed/30626807
http://dx.doi.org/10.2169/internalmedicine.1862-18
work_keys_str_mv AT satohtatsunori ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT matsubayashihiroyuki ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT ishiwatarihirotoshi ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT fujieshinya ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT kanekojunichi ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT satojunya ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT itosayo ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT kishidayoshihiro ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT imaikenichiro ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT hottakinichi ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT yoshidamasao ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT kawatanoboru ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT takizawakohei ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT kakushimanaomi ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT sawadaakihiro ruptureofpseudoaneurysmafterbiliarymetallicstentplacement
AT onohiroyuki ruptureofpseudoaneurysmafterbiliarymetallicstentplacement