Cargando…
Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement
Rupture of a pseudoaneurysm (PA) has been reported as a rare but serious adverse event associated with endoscopic biliary stenting. We herein report 2 cases of severe biliary bleeding from a PA that developed 10-14 days after placement of a self-expandable metallic stent (SEMS) for biliary malignanc...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society of Internal Medicine
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6548938/ https://www.ncbi.nlm.nih.gov/pubmed/30626807 http://dx.doi.org/10.2169/internalmedicine.1862-18 |
_version_ | 1783423903873368064 |
---|---|
author | Satoh, Tatsunori Matsubayashi, Hiroyuki Ishiwatari, Hirotoshi Fujie, Shinya Kaneko, Junichi Sato, Junya Ito, Sayo Kishida, Yoshihiro Imai, Kenichiro Hotta, Kinichi Yoshida, Masao Kawata, Noboru Takizawa, Kohei Kakushima, Naomi Sawada, Akihiro Ono, Hiroyuki |
author_facet | Satoh, Tatsunori Matsubayashi, Hiroyuki Ishiwatari, Hirotoshi Fujie, Shinya Kaneko, Junichi Sato, Junya Ito, Sayo Kishida, Yoshihiro Imai, Kenichiro Hotta, Kinichi Yoshida, Masao Kawata, Noboru Takizawa, Kohei Kakushima, Naomi Sawada, Akihiro Ono, Hiroyuki |
author_sort | Satoh, Tatsunori |
collection | PubMed |
description | Rupture of a pseudoaneurysm (PA) has been reported as a rare but serious adverse event associated with endoscopic biliary stenting. We herein report 2 cases of severe biliary bleeding from a PA that developed 10-14 days after placement of a self-expandable metallic stent (SEMS) for biliary malignancy. The first patient was successfully embolized with endovascular coiling. However, the second patient had wide-spreading cholangiocarcinoma and, despite being treated once by full coiling, developed a second rupture of PA two months after starting systemic chemotherapy. Clinicians should be aware of the possibility of PA and carefully follow stented patients after endovascular treatment. |
format | Online Article Text |
id | pubmed-6548938 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Japanese Society of Internal Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-65489382019-06-17 Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement Satoh, Tatsunori Matsubayashi, Hiroyuki Ishiwatari, Hirotoshi Fujie, Shinya Kaneko, Junichi Sato, Junya Ito, Sayo Kishida, Yoshihiro Imai, Kenichiro Hotta, Kinichi Yoshida, Masao Kawata, Noboru Takizawa, Kohei Kakushima, Naomi Sawada, Akihiro Ono, Hiroyuki Intern Med Case Report Rupture of a pseudoaneurysm (PA) has been reported as a rare but serious adverse event associated with endoscopic biliary stenting. We herein report 2 cases of severe biliary bleeding from a PA that developed 10-14 days after placement of a self-expandable metallic stent (SEMS) for biliary malignancy. The first patient was successfully embolized with endovascular coiling. However, the second patient had wide-spreading cholangiocarcinoma and, despite being treated once by full coiling, developed a second rupture of PA two months after starting systemic chemotherapy. Clinicians should be aware of the possibility of PA and carefully follow stented patients after endovascular treatment. The Japanese Society of Internal Medicine 2019-01-10 2019-05-15 /pmc/articles/PMC6548938/ /pubmed/30626807 http://dx.doi.org/10.2169/internalmedicine.1862-18 Text en Copyright © 2019 by The Japanese Society of Internal Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/ The Internal Medicine is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Satoh, Tatsunori Matsubayashi, Hiroyuki Ishiwatari, Hirotoshi Fujie, Shinya Kaneko, Junichi Sato, Junya Ito, Sayo Kishida, Yoshihiro Imai, Kenichiro Hotta, Kinichi Yoshida, Masao Kawata, Noboru Takizawa, Kohei Kakushima, Naomi Sawada, Akihiro Ono, Hiroyuki Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement |
title | Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement |
title_full | Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement |
title_fullStr | Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement |
title_full_unstemmed | Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement |
title_short | Rupture of Pseudoaneurysm after Biliary Metallic Stent Placement |
title_sort | rupture of pseudoaneurysm after biliary metallic stent placement |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6548938/ https://www.ncbi.nlm.nih.gov/pubmed/30626807 http://dx.doi.org/10.2169/internalmedicine.1862-18 |
work_keys_str_mv | AT satohtatsunori ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT matsubayashihiroyuki ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT ishiwatarihirotoshi ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT fujieshinya ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT kanekojunichi ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT satojunya ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT itosayo ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT kishidayoshihiro ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT imaikenichiro ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT hottakinichi ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT yoshidamasao ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT kawatanoboru ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT takizawakohei ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT kakushimanaomi ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT sawadaakihiro ruptureofpseudoaneurysmafterbiliarymetallicstentplacement AT onohiroyuki ruptureofpseudoaneurysmafterbiliarymetallicstentplacement |