Enhanced biofilm solubilization by urea in reverse osmosis membrane systems

Chemical cleaning is routinely performed in reverse osmosis (RO) plants for the regeneration of RO membranes that suffer from biofouling problems. The potential of urea as a chaotropic agent to enhance the solubilization of biofilm proteins has been reported briefly in the literature. In this paper...

Descripción completa

Detalles Bibliográficos
Autores principales: Sanawar, H., Pinel, I., Farhat, N.M., Bucs, Sz.S., Zlopasa, J., Kruithof, J.C., Witkamp, G.J., van Loosdrecht, M.C.M., Vrouwenvelder, J.S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6549900/
https://www.ncbi.nlm.nih.gov/pubmed/31194008
http://dx.doi.org/10.1016/j.wroa.2018.10.001
_version_ 1783424087341662208
author Sanawar, H.
Pinel, I.
Farhat, N.M.
Bucs, Sz.S.
Zlopasa, J.
Kruithof, J.C.
Witkamp, G.J.
van Loosdrecht, M.C.M.
Vrouwenvelder, J.S.
author_facet Sanawar, H.
Pinel, I.
Farhat, N.M.
Bucs, Sz.S.
Zlopasa, J.
Kruithof, J.C.
Witkamp, G.J.
van Loosdrecht, M.C.M.
Vrouwenvelder, J.S.
author_sort Sanawar, H.
collection PubMed
description Chemical cleaning is routinely performed in reverse osmosis (RO) plants for the regeneration of RO membranes that suffer from biofouling problems. The potential of urea as a chaotropic agent to enhance the solubilization of biofilm proteins has been reported briefly in the literature. In this paper the efficiency of urea cleaning for RO membrane systems has been compared to conventionally applied acid/alkali treatment. Preliminary assessment confirmed that urea did not damage the RO polyamide membranes and that the membrane cleaning efficiency increased with increasing concentrations of urea and temperature. Accelerated biofilm formation was carried out in membrane fouling simulators which were subsequently cleaned with (i) 0.01M sodium hydroxide (NaOH) and 0.1M hydrochloric acid (HCl) (typically applied in industry), (ii) urea (CO(NH(2))(2)) and hydrochloric acid, or (iii) urea only (1340 g/L(water)). The pressure drop over the flow channel was used to evaluate the efficiency of the applied chemical cleanings. Biomass removal was evaluated by measuring chemical oxygen demand (COD), adenosine triphosphate (ATP), protein, and carbohydrate content from the membrane and spacer surfaces after cleaning. In addition to protein and carbohydrate quantification of the extracellular polymeric substances (EPS), fluorescence excitation−emission matrix (FEEM) spectroscopy was used to distinguish the difference in organic matter of the remaining biomass to assess biofilm solubilization efficacy of the different cleaning agents. Results indicated that two-stage CO(NH(2))(2)/HCl cleaning was as effective as cleaning with NaOH/HCl in terms of restoring the feed channel pressure drop (>70% pressure drop decrease). One-stage cleaning with urea only was not as effective indicating the importance of the second-stage low pH acid cleaning in weakening the biofilm matrix. All three chemical cleaning protocols were equally effective in reducing the concentration of predominant EPS components protein and carbohydrate (>50% reduction in concentrations). However, urea-based cleaning strategies were more effective in solubilizing protein-like matter and tyrosine-containing proteins. Furthermore, ATP measurements showed that biomass inactivation was up to two-fold greater after treatment with urea-based chemical cleanings compared to the conventional acid/alkali treatment. The applicability of urea as an alternative, economical, eco-friendly and effective chemical cleaning agent for the control of biological fouling was successfully demonstrated.
format Online
Article
Text
id pubmed-6549900
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-65499002019-06-11 Enhanced biofilm solubilization by urea in reverse osmosis membrane systems Sanawar, H. Pinel, I. Farhat, N.M. Bucs, Sz.S. Zlopasa, J. Kruithof, J.C. Witkamp, G.J. van Loosdrecht, M.C.M. Vrouwenvelder, J.S. Water Res X Full Paper Chemical cleaning is routinely performed in reverse osmosis (RO) plants for the regeneration of RO membranes that suffer from biofouling problems. The potential of urea as a chaotropic agent to enhance the solubilization of biofilm proteins has been reported briefly in the literature. In this paper the efficiency of urea cleaning for RO membrane systems has been compared to conventionally applied acid/alkali treatment. Preliminary assessment confirmed that urea did not damage the RO polyamide membranes and that the membrane cleaning efficiency increased with increasing concentrations of urea and temperature. Accelerated biofilm formation was carried out in membrane fouling simulators which were subsequently cleaned with (i) 0.01M sodium hydroxide (NaOH) and 0.1M hydrochloric acid (HCl) (typically applied in industry), (ii) urea (CO(NH(2))(2)) and hydrochloric acid, or (iii) urea only (1340 g/L(water)). The pressure drop over the flow channel was used to evaluate the efficiency of the applied chemical cleanings. Biomass removal was evaluated by measuring chemical oxygen demand (COD), adenosine triphosphate (ATP), protein, and carbohydrate content from the membrane and spacer surfaces after cleaning. In addition to protein and carbohydrate quantification of the extracellular polymeric substances (EPS), fluorescence excitation−emission matrix (FEEM) spectroscopy was used to distinguish the difference in organic matter of the remaining biomass to assess biofilm solubilization efficacy of the different cleaning agents. Results indicated that two-stage CO(NH(2))(2)/HCl cleaning was as effective as cleaning with NaOH/HCl in terms of restoring the feed channel pressure drop (>70% pressure drop decrease). One-stage cleaning with urea only was not as effective indicating the importance of the second-stage low pH acid cleaning in weakening the biofilm matrix. All three chemical cleaning protocols were equally effective in reducing the concentration of predominant EPS components protein and carbohydrate (>50% reduction in concentrations). However, urea-based cleaning strategies were more effective in solubilizing protein-like matter and tyrosine-containing proteins. Furthermore, ATP measurements showed that biomass inactivation was up to two-fold greater after treatment with urea-based chemical cleanings compared to the conventional acid/alkali treatment. The applicability of urea as an alternative, economical, eco-friendly and effective chemical cleaning agent for the control of biological fouling was successfully demonstrated. Elsevier 2018-10-15 /pmc/articles/PMC6549900/ /pubmed/31194008 http://dx.doi.org/10.1016/j.wroa.2018.10.001 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Full Paper
Sanawar, H.
Pinel, I.
Farhat, N.M.
Bucs, Sz.S.
Zlopasa, J.
Kruithof, J.C.
Witkamp, G.J.
van Loosdrecht, M.C.M.
Vrouwenvelder, J.S.
Enhanced biofilm solubilization by urea in reverse osmosis membrane systems
title Enhanced biofilm solubilization by urea in reverse osmosis membrane systems
title_full Enhanced biofilm solubilization by urea in reverse osmosis membrane systems
title_fullStr Enhanced biofilm solubilization by urea in reverse osmosis membrane systems
title_full_unstemmed Enhanced biofilm solubilization by urea in reverse osmosis membrane systems
title_short Enhanced biofilm solubilization by urea in reverse osmosis membrane systems
title_sort enhanced biofilm solubilization by urea in reverse osmosis membrane systems
topic Full Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6549900/
https://www.ncbi.nlm.nih.gov/pubmed/31194008
http://dx.doi.org/10.1016/j.wroa.2018.10.001
work_keys_str_mv AT sanawarh enhancedbiofilmsolubilizationbyureainreverseosmosismembranesystems
AT pineli enhancedbiofilmsolubilizationbyureainreverseosmosismembranesystems
AT farhatnm enhancedbiofilmsolubilizationbyureainreverseosmosismembranesystems
AT bucsszs enhancedbiofilmsolubilizationbyureainreverseosmosismembranesystems
AT zlopasaj enhancedbiofilmsolubilizationbyureainreverseosmosismembranesystems
AT kruithofjc enhancedbiofilmsolubilizationbyureainreverseosmosismembranesystems
AT witkampgj enhancedbiofilmsolubilizationbyureainreverseosmosismembranesystems
AT vanloosdrechtmcm enhancedbiofilmsolubilizationbyureainreverseosmosismembranesystems
AT vrouwenvelderjs enhancedbiofilmsolubilizationbyureainreverseosmosismembranesystems