Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers

Thoracic electrical bioimpedance (TEB) and transthoracic echocardiography (TTE) are non-invasive methods to estimate stroke volume (SV) and cardiac output (CO). Thoracic electrical bioimpedance is not in widespread clinical use with reports of inaccurate cardiac output estimation compared to invasiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Harford, Mirae, Clark, Samuel H., Smythe, Jodie F., Gerry, Stephen, Villarroel, Mauricio, Jorge, Joao, Chaichulee, Sitthichok, Tarassenko, Lionel, Young, Duncan, Watkinson, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6550124/
https://www.ncbi.nlm.nih.gov/pubmed/30983444
http://dx.doi.org/10.1080/03091902.2019.1599074
_version_ 1783424132191354880
author Harford, Mirae
Clark, Samuel H.
Smythe, Jodie F.
Gerry, Stephen
Villarroel, Mauricio
Jorge, Joao
Chaichulee, Sitthichok
Tarassenko, Lionel
Young, Duncan
Watkinson, Peter
author_facet Harford, Mirae
Clark, Samuel H.
Smythe, Jodie F.
Gerry, Stephen
Villarroel, Mauricio
Jorge, Joao
Chaichulee, Sitthichok
Tarassenko, Lionel
Young, Duncan
Watkinson, Peter
author_sort Harford, Mirae
collection PubMed
description Thoracic electrical bioimpedance (TEB) and transthoracic echocardiography (TTE) are non-invasive methods to estimate stroke volume (SV) and cardiac output (CO). Thoracic electrical bioimpedance is not in widespread clinical use with reports of inaccurate cardiac output estimation compared to invasive monitors, particularly in non-healthy populations. We explore its use as a trend monitor by comparing it against thoracic echocardiography in fifteen healthy volunteers undergoing two physical challenges designed to vary cardiac output. Of all paired values, 54.6% showed gross trend agreement and only 1.9% showed direct disagreement between the two monitors. Our results show thoracic bioimpedance may have a role as a non-invasive cardiac output trend monitor in healthy volunteer studies.
format Online
Article
Text
id pubmed-6550124
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-65501242019-06-19 Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers Harford, Mirae Clark, Samuel H. Smythe, Jodie F. Gerry, Stephen Villarroel, Mauricio Jorge, Joao Chaichulee, Sitthichok Tarassenko, Lionel Young, Duncan Watkinson, Peter J Med Eng Technol Article Thoracic electrical bioimpedance (TEB) and transthoracic echocardiography (TTE) are non-invasive methods to estimate stroke volume (SV) and cardiac output (CO). Thoracic electrical bioimpedance is not in widespread clinical use with reports of inaccurate cardiac output estimation compared to invasive monitors, particularly in non-healthy populations. We explore its use as a trend monitor by comparing it against thoracic echocardiography in fifteen healthy volunteers undergoing two physical challenges designed to vary cardiac output. Of all paired values, 54.6% showed gross trend agreement and only 1.9% showed direct disagreement between the two monitors. Our results show thoracic bioimpedance may have a role as a non-invasive cardiac output trend monitor in healthy volunteer studies. Taylor & Francis 2019-04-15 /pmc/articles/PMC6550124/ /pubmed/30983444 http://dx.doi.org/10.1080/03091902.2019.1599074 Text en © 2019 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Harford, Mirae
Clark, Samuel H.
Smythe, Jodie F.
Gerry, Stephen
Villarroel, Mauricio
Jorge, Joao
Chaichulee, Sitthichok
Tarassenko, Lionel
Young, Duncan
Watkinson, Peter
Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_full Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_fullStr Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_full_unstemmed Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_short Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_sort non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus doppler echocardiography in healthy volunteers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6550124/
https://www.ncbi.nlm.nih.gov/pubmed/30983444
http://dx.doi.org/10.1080/03091902.2019.1599074
work_keys_str_mv AT harfordmirae noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT clarksamuelh noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT smythejodief noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT gerrystephen noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT villarroelmauricio noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT jorgejoao noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT chaichuleesitthichok noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT tarassenkolionel noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT youngduncan noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT watkinsonpeter noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers