Cargando…

SAT-376 Dynamic Modeling of the 1 mg Overnight Dexamethasone Suppression Test: Sources of Variability and Strategies to Improve Diagnostic Accuracy for Detection of Autonomous Cortisol Secretion in Adrenal Adenoma Patients

Among patients with adrenal adenoma, the 1 mg overnight dexamethasone suppression test (DST) is commonly used to help identify patients with biochemical evidence of autonomous cortisol secretion (ACS). The diagnostic accuracy of the DST in this setting is only fair, as illustrated by the application...

Descripción completa

Detalles Bibliográficos
Autores principales: Kambhatla, Akshaya, Qualls, Clifford, Urban, Frank, Dorin, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Endocrine Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6552027/
http://dx.doi.org/10.1210/js.2019-SAT-376
_version_ 1783424507277475840
author Kambhatla, Akshaya
Qualls, Clifford
Urban, Frank
Dorin, Richard
author_facet Kambhatla, Akshaya
Qualls, Clifford
Urban, Frank
Dorin, Richard
author_sort Kambhatla, Akshaya
collection PubMed
description Among patients with adrenal adenoma, the 1 mg overnight dexamethasone suppression test (DST) is commonly used to help identify patients with biochemical evidence of autonomous cortisol secretion (ACS). The diagnostic accuracy of the DST in this setting is only fair, as illustrated by the application of different cut-scores for DEX-suppressed cortisol concentrations (e.g. 50 vs. 138 nM) favoring sensitivity or specificity, respectively (1). In the present study we sought to model the predictors of the DST to better characterize sources of variation and error in the diagnostic test. Forward solutions for DEX-suppressed total and free cortisol concentrations from midnight to 8 AM were obtained using simultaneous solution of differential equations in a dynamic 3-compartment model of free cortisol appearance, elimination, and reversible binding to serum proteins (2). Monte Carlo simulation was performed based on published distributional data for controls (n=1000) and ACS patients (n=1000). Predictor variables were assessed using standardized beta (STB) coefficients, which represent change in the standard deviation (SD) of the outcome (numerator, i.e. DEX-suppressed cortisol concentration) for each SD change in a predictor (denominator) in a multivariable context (2). The analysis confirmed diagnostic accuracy of the DST consistent with published guidelines (1). Significant predictors of DEX-suppressed cortisol included ACTH-independent cortisol secretion rate (CSRmin), free cortisol half-life, and the concentration of midnight serum total cortisol, corticosteroid binding globulin (CBG), and albumin (all P<0.01). The predictor variables having STB coefficients >0.4 included CSRmin (STB=0.67), free cortisol half-life (STB=0.53), and CBG (STB=0.44), with smaller influence of midnight total serum cortisol (STB=0.14), and albumin (STB=0.04) concentrations. STBs for DEX-suppressed free cortisol concentration were like those observed for total cortisol except that the influence of CBG was eliminated. Using a DEX-suppressed free cortisol cut-score of 2.5 nM improved sensitivity and specificity compared to DEX-suppressed total cortisol (P<0.001). We conclude that our model for DST agrees with experimental literature demonstrating limited diagnostic accuracy of the test and we have identified multiple factors that affect the DEX-suppressed cortisol concentration in both control and ACS populations. In addition, strategies to adjust for confounding variables, such as use of DEX-suppressed free cortisol, might improve diagnostic accuracy of the DST. References: (1) Fassnacht et al. Euro J Endocrinol 2016 August;172(2):(2)G1-34, (2) Dorin et al., J Endocrinol Soc 2017 July;1(7):945-56.
format Online
Article
Text
id pubmed-6552027
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Endocrine Society
record_format MEDLINE/PubMed
spelling pubmed-65520272019-06-13 SAT-376 Dynamic Modeling of the 1 mg Overnight Dexamethasone Suppression Test: Sources of Variability and Strategies to Improve Diagnostic Accuracy for Detection of Autonomous Cortisol Secretion in Adrenal Adenoma Patients Kambhatla, Akshaya Qualls, Clifford Urban, Frank Dorin, Richard J Endocr Soc Adrenal Among patients with adrenal adenoma, the 1 mg overnight dexamethasone suppression test (DST) is commonly used to help identify patients with biochemical evidence of autonomous cortisol secretion (ACS). The diagnostic accuracy of the DST in this setting is only fair, as illustrated by the application of different cut-scores for DEX-suppressed cortisol concentrations (e.g. 50 vs. 138 nM) favoring sensitivity or specificity, respectively (1). In the present study we sought to model the predictors of the DST to better characterize sources of variation and error in the diagnostic test. Forward solutions for DEX-suppressed total and free cortisol concentrations from midnight to 8 AM were obtained using simultaneous solution of differential equations in a dynamic 3-compartment model of free cortisol appearance, elimination, and reversible binding to serum proteins (2). Monte Carlo simulation was performed based on published distributional data for controls (n=1000) and ACS patients (n=1000). Predictor variables were assessed using standardized beta (STB) coefficients, which represent change in the standard deviation (SD) of the outcome (numerator, i.e. DEX-suppressed cortisol concentration) for each SD change in a predictor (denominator) in a multivariable context (2). The analysis confirmed diagnostic accuracy of the DST consistent with published guidelines (1). Significant predictors of DEX-suppressed cortisol included ACTH-independent cortisol secretion rate (CSRmin), free cortisol half-life, and the concentration of midnight serum total cortisol, corticosteroid binding globulin (CBG), and albumin (all P<0.01). The predictor variables having STB coefficients >0.4 included CSRmin (STB=0.67), free cortisol half-life (STB=0.53), and CBG (STB=0.44), with smaller influence of midnight total serum cortisol (STB=0.14), and albumin (STB=0.04) concentrations. STBs for DEX-suppressed free cortisol concentration were like those observed for total cortisol except that the influence of CBG was eliminated. Using a DEX-suppressed free cortisol cut-score of 2.5 nM improved sensitivity and specificity compared to DEX-suppressed total cortisol (P<0.001). We conclude that our model for DST agrees with experimental literature demonstrating limited diagnostic accuracy of the test and we have identified multiple factors that affect the DEX-suppressed cortisol concentration in both control and ACS populations. In addition, strategies to adjust for confounding variables, such as use of DEX-suppressed free cortisol, might improve diagnostic accuracy of the DST. References: (1) Fassnacht et al. Euro J Endocrinol 2016 August;172(2):(2)G1-34, (2) Dorin et al., J Endocrinol Soc 2017 July;1(7):945-56. Endocrine Society 2019-04-30 /pmc/articles/PMC6552027/ http://dx.doi.org/10.1210/js.2019-SAT-376 Text en Copyright © 2019 Endocrine Society https://creativecommons.org/licenses/by-nc-nd/4.0/ This article has been published under the terms of the Creative Commons Attribution Non-Commercial, No-Derivatives License (CC BY-NC-ND; https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Adrenal
Kambhatla, Akshaya
Qualls, Clifford
Urban, Frank
Dorin, Richard
SAT-376 Dynamic Modeling of the 1 mg Overnight Dexamethasone Suppression Test: Sources of Variability and Strategies to Improve Diagnostic Accuracy for Detection of Autonomous Cortisol Secretion in Adrenal Adenoma Patients
title SAT-376 Dynamic Modeling of the 1 mg Overnight Dexamethasone Suppression Test: Sources of Variability and Strategies to Improve Diagnostic Accuracy for Detection of Autonomous Cortisol Secretion in Adrenal Adenoma Patients
title_full SAT-376 Dynamic Modeling of the 1 mg Overnight Dexamethasone Suppression Test: Sources of Variability and Strategies to Improve Diagnostic Accuracy for Detection of Autonomous Cortisol Secretion in Adrenal Adenoma Patients
title_fullStr SAT-376 Dynamic Modeling of the 1 mg Overnight Dexamethasone Suppression Test: Sources of Variability and Strategies to Improve Diagnostic Accuracy for Detection of Autonomous Cortisol Secretion in Adrenal Adenoma Patients
title_full_unstemmed SAT-376 Dynamic Modeling of the 1 mg Overnight Dexamethasone Suppression Test: Sources of Variability and Strategies to Improve Diagnostic Accuracy for Detection of Autonomous Cortisol Secretion in Adrenal Adenoma Patients
title_short SAT-376 Dynamic Modeling of the 1 mg Overnight Dexamethasone Suppression Test: Sources of Variability and Strategies to Improve Diagnostic Accuracy for Detection of Autonomous Cortisol Secretion in Adrenal Adenoma Patients
title_sort sat-376 dynamic modeling of the 1 mg overnight dexamethasone suppression test: sources of variability and strategies to improve diagnostic accuracy for detection of autonomous cortisol secretion in adrenal adenoma patients
topic Adrenal
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6552027/
http://dx.doi.org/10.1210/js.2019-SAT-376
work_keys_str_mv AT kambhatlaakshaya sat376dynamicmodelingofthe1mgovernightdexamethasonesuppressiontestsourcesofvariabilityandstrategiestoimprovediagnosticaccuracyfordetectionofautonomouscortisolsecretioninadrenaladenomapatients
AT quallsclifford sat376dynamicmodelingofthe1mgovernightdexamethasonesuppressiontestsourcesofvariabilityandstrategiestoimprovediagnosticaccuracyfordetectionofautonomouscortisolsecretioninadrenaladenomapatients
AT urbanfrank sat376dynamicmodelingofthe1mgovernightdexamethasonesuppressiontestsourcesofvariabilityandstrategiestoimprovediagnosticaccuracyfordetectionofautonomouscortisolsecretioninadrenaladenomapatients
AT dorinrichard sat376dynamicmodelingofthe1mgovernightdexamethasonesuppressiontestsourcesofvariabilityandstrategiestoimprovediagnosticaccuracyfordetectionofautonomouscortisolsecretioninadrenaladenomapatients