SAT-011 Quantification of Testosterone, Androstenedione and 17-Hydroxyprogesterone Collected Using Mitra®Micro Sampling Devices

Introduction Measurement of total plasma testosterone (T), androstenedione (A4) and 17-hydroxyprogesterone (17OHP) typically requires a venous sample. A highly sensitive and specific assay was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) after extraction from a Mitra® vo...

Descripción completa

Detalles Bibliográficos
Autores principales: Marshall, David, Keevil, Brian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Endocrine Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6552561/
http://dx.doi.org/10.1210/js.2019-SAT-011
_version_ 1783424621066846208
author Marshall, David
Keevil, Brian
author_facet Marshall, David
Keevil, Brian
author_sort Marshall, David
collection PubMed
description Introduction Measurement of total plasma testosterone (T), androstenedione (A4) and 17-hydroxyprogesterone (17OHP) typically requires a venous sample. A highly sensitive and specific assay was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) after extraction from a Mitra® volumetric absorptive microsampling (VAMs) device. VAMs devices are small absorptive polymer tips which absorb a fixed amount of blood (1); they can be dried after collection of finger prick blood and stored prior to analysis. Differences in binding in whole blood compared to serum require the quantification of haematocrit using a published protocol (2), thus allowing an estimated serum result to be generated. Method Pre-mixed calibrator/sample (10 µL) was combined with deionised water and mixed internal standard, after vortexing MTBE was added and mixed by inversion for 1 minute. The supernatant was transferred to a clean 2 mL deep-well plate, dried down and re-constituted with 100 µL 50:50 methanol/water. Mitra® tips were prepared from anonymised whole blood samples in the laboratory and compared to the corresponding plasma using the same method. Results Mean recovery was 86% for A4, 102% for T and 97% for 17OHP, the lower limit of quantification was 1 nmol/L for A4, 1 nmol/L for testosterone and 4 nmol/L for 17OHP. Ion suppression was within acceptable criteria for all the analytes measured. For the samples prepared in the laboratory, comparisons for T, A4 and 17OHP the R-squared values were 0.95, 0.93 and 0.95 respectively with a minimal bias. Summary We have developed a robust assay for LC-MS/MS measurement of VAMs for T, A4, and 17OHP in a routine clinical laboratory. It is simple, reproducible and easy to perform and may have implications for monitoring of T therapy in hypogonadal males or screening/monitoring of patients with congenital adrenal hyperplasia. In-house comparisons of T, A4 and 17OHP compared well when haematocrit was used to adjust for the space occupying effect of red cells. References 1. Spooner N, Denniff P, Michielsen L, De Vries R, Ji Q.C, Arnold ME, Woods K, Woolf EJ, Xu Y, Boutet V, Zane P, Kushon S, Rudge JB (2015) A device for dried blood microsampling in quantitative bioanalysis: overcoming the issues associated with blood hematocrit. Bioanalysis 7, 653-659. 2. Prediction of haematocrit in dried blood spots from the measurement of haemoglobin using commercially available sodium lauryl sulphate. G Richardson, D Marshall, BG Keevil, Ann Clin Biochem. 2018 May;55(3):363-367
format Online
Article
Text
id pubmed-6552561
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Endocrine Society
record_format MEDLINE/PubMed
spelling pubmed-65525612019-06-13 SAT-011 Quantification of Testosterone, Androstenedione and 17-Hydroxyprogesterone Collected Using Mitra®Micro Sampling Devices Marshall, David Keevil, Brian J Endocr Soc Steroid Hormones and Receptors Introduction Measurement of total plasma testosterone (T), androstenedione (A4) and 17-hydroxyprogesterone (17OHP) typically requires a venous sample. A highly sensitive and specific assay was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) after extraction from a Mitra® volumetric absorptive microsampling (VAMs) device. VAMs devices are small absorptive polymer tips which absorb a fixed amount of blood (1); they can be dried after collection of finger prick blood and stored prior to analysis. Differences in binding in whole blood compared to serum require the quantification of haematocrit using a published protocol (2), thus allowing an estimated serum result to be generated. Method Pre-mixed calibrator/sample (10 µL) was combined with deionised water and mixed internal standard, after vortexing MTBE was added and mixed by inversion for 1 minute. The supernatant was transferred to a clean 2 mL deep-well plate, dried down and re-constituted with 100 µL 50:50 methanol/water. Mitra® tips were prepared from anonymised whole blood samples in the laboratory and compared to the corresponding plasma using the same method. Results Mean recovery was 86% for A4, 102% for T and 97% for 17OHP, the lower limit of quantification was 1 nmol/L for A4, 1 nmol/L for testosterone and 4 nmol/L for 17OHP. Ion suppression was within acceptable criteria for all the analytes measured. For the samples prepared in the laboratory, comparisons for T, A4 and 17OHP the R-squared values were 0.95, 0.93 and 0.95 respectively with a minimal bias. Summary We have developed a robust assay for LC-MS/MS measurement of VAMs for T, A4, and 17OHP in a routine clinical laboratory. It is simple, reproducible and easy to perform and may have implications for monitoring of T therapy in hypogonadal males or screening/monitoring of patients with congenital adrenal hyperplasia. In-house comparisons of T, A4 and 17OHP compared well when haematocrit was used to adjust for the space occupying effect of red cells. References 1. Spooner N, Denniff P, Michielsen L, De Vries R, Ji Q.C, Arnold ME, Woods K, Woolf EJ, Xu Y, Boutet V, Zane P, Kushon S, Rudge JB (2015) A device for dried blood microsampling in quantitative bioanalysis: overcoming the issues associated with blood hematocrit. Bioanalysis 7, 653-659. 2. Prediction of haematocrit in dried blood spots from the measurement of haemoglobin using commercially available sodium lauryl sulphate. G Richardson, D Marshall, BG Keevil, Ann Clin Biochem. 2018 May;55(3):363-367 Endocrine Society 2019-04-30 /pmc/articles/PMC6552561/ http://dx.doi.org/10.1210/js.2019-SAT-011 Text en Copyright © 2019 Endocrine Society https://creativecommons.org/licenses/by-nc-nd/4.0/ This article has been published under the terms of the Creative Commons Attribution Non-Commercial, No-Derivatives License (CC BY-NC-ND; https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Steroid Hormones and Receptors
Marshall, David
Keevil, Brian
SAT-011 Quantification of Testosterone, Androstenedione and 17-Hydroxyprogesterone Collected Using Mitra®Micro Sampling Devices
title SAT-011 Quantification of Testosterone, Androstenedione and 17-Hydroxyprogesterone Collected Using Mitra®Micro Sampling Devices
title_full SAT-011 Quantification of Testosterone, Androstenedione and 17-Hydroxyprogesterone Collected Using Mitra®Micro Sampling Devices
title_fullStr SAT-011 Quantification of Testosterone, Androstenedione and 17-Hydroxyprogesterone Collected Using Mitra®Micro Sampling Devices
title_full_unstemmed SAT-011 Quantification of Testosterone, Androstenedione and 17-Hydroxyprogesterone Collected Using Mitra®Micro Sampling Devices
title_short SAT-011 Quantification of Testosterone, Androstenedione and 17-Hydroxyprogesterone Collected Using Mitra®Micro Sampling Devices
title_sort sat-011 quantification of testosterone, androstenedione and 17-hydroxyprogesterone collected using mitra®micro sampling devices
topic Steroid Hormones and Receptors
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6552561/
http://dx.doi.org/10.1210/js.2019-SAT-011
work_keys_str_mv AT marshalldavid sat011quantificationoftestosteroneandrostenedioneand17hydroxyprogesteronecollectedusingmitramicrosamplingdevices
AT keevilbrian sat011quantificationoftestosteroneandrostenedioneand17hydroxyprogesteronecollectedusingmitramicrosamplingdevices