Cargando…
Hybrid clear corneal micro-incision surgical technique for stage 5 retinopathy of prematurity
A safe technique for entry incisions and closure in stage 5 retinopathy of prematurity (ROP) surgery is being described. Three 23G clear corneal incisions are made which allow for safe and snug entry of 25G calibrated infusion and 25G instruments for performing lensectomy, membrane removal and vitre...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6552579/ https://www.ncbi.nlm.nih.gov/pubmed/31124519 http://dx.doi.org/10.4103/ijo.IJO_420_19 |
_version_ | 1783424625268490240 |
---|---|
author | Chandra, Parijat Kumawat, Devesh Tewari, Ruchir |
author_facet | Chandra, Parijat Kumawat, Devesh Tewari, Ruchir |
author_sort | Chandra, Parijat |
collection | PubMed |
description | A safe technique for entry incisions and closure in stage 5 retinopathy of prematurity (ROP) surgery is being described. Three 23G clear corneal incisions are made which allow for safe and snug entry of 25G calibrated infusion and 25G instruments for performing lensectomy, membrane removal and vitrectomy. At the end of surgery, air is injected and corneal entries are hydrated for sutureless closure. The technique was performed in 50 eyes of 36 children with stage 5 ROP. The hybrid technique ensured safe entry and exit with stable anterior chamber during surgery. None of the cases developed retinal breaks during surgical entry nor had any complications such as hypotony, flat anterior chamber, hyphaema or corneal edema in post operative period. Clear corneal entry using 23G incisions for 25G instrument access is a safe and effective technique for performing lensectomy and vitrectomy with sutureless closure in cases with stage 5 ROP. |
format | Online Article Text |
id | pubmed-6552579 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-65525792019-06-13 Hybrid clear corneal micro-incision surgical technique for stage 5 retinopathy of prematurity Chandra, Parijat Kumawat, Devesh Tewari, Ruchir Indian J Ophthalmol Surgical Technique A safe technique for entry incisions and closure in stage 5 retinopathy of prematurity (ROP) surgery is being described. Three 23G clear corneal incisions are made which allow for safe and snug entry of 25G calibrated infusion and 25G instruments for performing lensectomy, membrane removal and vitrectomy. At the end of surgery, air is injected and corneal entries are hydrated for sutureless closure. The technique was performed in 50 eyes of 36 children with stage 5 ROP. The hybrid technique ensured safe entry and exit with stable anterior chamber during surgery. None of the cases developed retinal breaks during surgical entry nor had any complications such as hypotony, flat anterior chamber, hyphaema or corneal edema in post operative period. Clear corneal entry using 23G incisions for 25G instrument access is a safe and effective technique for performing lensectomy and vitrectomy with sutureless closure in cases with stage 5 ROP. Wolters Kluwer - Medknow 2019-06 /pmc/articles/PMC6552579/ /pubmed/31124519 http://dx.doi.org/10.4103/ijo.IJO_420_19 Text en Copyright: © 2019 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Surgical Technique Chandra, Parijat Kumawat, Devesh Tewari, Ruchir Hybrid clear corneal micro-incision surgical technique for stage 5 retinopathy of prematurity |
title | Hybrid clear corneal micro-incision surgical technique for stage 5 retinopathy of prematurity |
title_full | Hybrid clear corneal micro-incision surgical technique for stage 5 retinopathy of prematurity |
title_fullStr | Hybrid clear corneal micro-incision surgical technique for stage 5 retinopathy of prematurity |
title_full_unstemmed | Hybrid clear corneal micro-incision surgical technique for stage 5 retinopathy of prematurity |
title_short | Hybrid clear corneal micro-incision surgical technique for stage 5 retinopathy of prematurity |
title_sort | hybrid clear corneal micro-incision surgical technique for stage 5 retinopathy of prematurity |
topic | Surgical Technique |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6552579/ https://www.ncbi.nlm.nih.gov/pubmed/31124519 http://dx.doi.org/10.4103/ijo.IJO_420_19 |
work_keys_str_mv | AT chandraparijat hybridclearcornealmicroincisionsurgicaltechniqueforstage5retinopathyofprematurity AT kumawatdevesh hybridclearcornealmicroincisionsurgicaltechniqueforstage5retinopathyofprematurity AT tewariruchir hybridclearcornealmicroincisionsurgicaltechniqueforstage5retinopathyofprematurity |