Cargando…
Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures
PURPOSE: To systematically evaluate the effects of virtual tube current reduction and sparse sampling on image quality and vertebral fracture diagnostics in multi-detector computed tomography (MDCT). MATERIALS AND METHODS: In routine MDCT scans of 35 patients (80.0% females, 70.6 ± 14.2 years, 65.7%...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6554251/ https://www.ncbi.nlm.nih.gov/pubmed/30903337 http://dx.doi.org/10.1007/s00330-019-06090-2 |
_version_ | 1783424932782276608 |
---|---|
author | Sollmann, Nico Mei, Kai Hedderich, Dennis M. Maegerlein, Christian Kopp, Felix K. Löffler, Maximilian T. Zimmer, Claus Rummeny, Ernst J. Kirschke, Jan S. Baum, Thomas Noël, Peter B. |
author_facet | Sollmann, Nico Mei, Kai Hedderich, Dennis M. Maegerlein, Christian Kopp, Felix K. Löffler, Maximilian T. Zimmer, Claus Rummeny, Ernst J. Kirschke, Jan S. Baum, Thomas Noël, Peter B. |
author_sort | Sollmann, Nico |
collection | PubMed |
description | PURPOSE: To systematically evaluate the effects of virtual tube current reduction and sparse sampling on image quality and vertebral fracture diagnostics in multi-detector computed tomography (MDCT). MATERIALS AND METHODS: In routine MDCT scans of 35 patients (80.0% females, 70.6 ± 14.2 years, 65.7% showing vertebral fractures), reduced radiation doses were retrospectively simulated by virtually lowering tube currents and applying sparse sampling, considering 50%, 25%, and 10% of the original tube current and projections, respectively. Two readers evaluated items of image quality and presence of vertebral fractures. Readout between the evaluations in the original images and those with virtually lowered tube currents or sparse sampling were compared. RESULTS: A significant difference was revealed between the evaluations of image quality between MDCT with virtually lowered tube current and sparse-sampled MDCT (p < 0.001). Sparse-sampled data with only 25% of original projections still showed good to very good overall image quality and contrast of vertebrae as well as minimal artifacts. There were no missed fractures in sparse-sampled MDCT with 50% reduction of projections, and clinically acceptable determination of fracture age was possible in MDCT with 75% reduction of projections, in contrast to MDCT with 50% or 75% virtual tube current reduction, respectively. CONCLUSION: Sparse-sampled MDCT provides adequate image quality and diagnostic accuracy for vertebral fracture detection with 50% of original projections in contrast to corresponding MDCT with lowered tube current. Thus, sparse sampling is a promising technique for dose reductions in MDCT that could be introduced in future generations of scanners. KEY POINTS: • MDCT with a reduction of projection numbers of 50% still showed high diagnostic accuracy without any missed vertebral fractures. • Clinically acceptable determination of vertebral fracture age was possible in MDCT with a reduction of projection numbers of 75%. • With sparse sampling, higher reductions in radiation exposure can be achieved without compromised image or diagnostic quality in routine MDCT of the spine as compared to MDCT with reduced tube currents. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00330-019-06090-2) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6554251 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-65542512019-06-21 Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures Sollmann, Nico Mei, Kai Hedderich, Dennis M. Maegerlein, Christian Kopp, Felix K. Löffler, Maximilian T. Zimmer, Claus Rummeny, Ernst J. Kirschke, Jan S. Baum, Thomas Noël, Peter B. Eur Radiol Computed Tomography PURPOSE: To systematically evaluate the effects of virtual tube current reduction and sparse sampling on image quality and vertebral fracture diagnostics in multi-detector computed tomography (MDCT). MATERIALS AND METHODS: In routine MDCT scans of 35 patients (80.0% females, 70.6 ± 14.2 years, 65.7% showing vertebral fractures), reduced radiation doses were retrospectively simulated by virtually lowering tube currents and applying sparse sampling, considering 50%, 25%, and 10% of the original tube current and projections, respectively. Two readers evaluated items of image quality and presence of vertebral fractures. Readout between the evaluations in the original images and those with virtually lowered tube currents or sparse sampling were compared. RESULTS: A significant difference was revealed between the evaluations of image quality between MDCT with virtually lowered tube current and sparse-sampled MDCT (p < 0.001). Sparse-sampled data with only 25% of original projections still showed good to very good overall image quality and contrast of vertebrae as well as minimal artifacts. There were no missed fractures in sparse-sampled MDCT with 50% reduction of projections, and clinically acceptable determination of fracture age was possible in MDCT with 75% reduction of projections, in contrast to MDCT with 50% or 75% virtual tube current reduction, respectively. CONCLUSION: Sparse-sampled MDCT provides adequate image quality and diagnostic accuracy for vertebral fracture detection with 50% of original projections in contrast to corresponding MDCT with lowered tube current. Thus, sparse sampling is a promising technique for dose reductions in MDCT that could be introduced in future generations of scanners. KEY POINTS: • MDCT with a reduction of projection numbers of 50% still showed high diagnostic accuracy without any missed vertebral fractures. • Clinically acceptable determination of vertebral fracture age was possible in MDCT with a reduction of projection numbers of 75%. • With sparse sampling, higher reductions in radiation exposure can be achieved without compromised image or diagnostic quality in routine MDCT of the spine as compared to MDCT with reduced tube currents. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00330-019-06090-2) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-03-22 2019 /pmc/articles/PMC6554251/ /pubmed/30903337 http://dx.doi.org/10.1007/s00330-019-06090-2 Text en © The Author(s) 2019 OpenAccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Computed Tomography Sollmann, Nico Mei, Kai Hedderich, Dennis M. Maegerlein, Christian Kopp, Felix K. Löffler, Maximilian T. Zimmer, Claus Rummeny, Ernst J. Kirschke, Jan S. Baum, Thomas Noël, Peter B. Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures |
title | Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures |
title_full | Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures |
title_fullStr | Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures |
title_full_unstemmed | Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures |
title_short | Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures |
title_sort | multi-detector ct imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures |
topic | Computed Tomography |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6554251/ https://www.ncbi.nlm.nih.gov/pubmed/30903337 http://dx.doi.org/10.1007/s00330-019-06090-2 |
work_keys_str_mv | AT sollmannnico multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT meikai multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT hedderichdennism multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT maegerleinchristian multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT koppfelixk multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT lofflermaximiliant multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT zimmerclaus multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT rummenyernstj multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT kirschkejans multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT baumthomas multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures AT noelpeterb multidetectorctimagingimpactofvirtualtubecurrentreductionandsparsesamplingondetectionofvertebralfractures |