Cargando…

New high intensity fibreoptic phototherapy devices in healthy newborns: a single pad wrapped around the neonate body in comparison with a double pad device

BACKGROUND: Fibreoptic Phototherapy (FPT) allows to lower total serum bilirubin (TSB) levels in healthy neonates maintained in rooming-in with their mothers. The 2004 Cochrane review showed that, differently from preterm neonates, FPT was not as effective as traditional phototherapy in term neonates...

Descripción completa

Detalles Bibliográficos
Autores principales: Luciano, R., Mancini, G., Cota, F., Romano, A., Purcaro, V., Lerro, F., Corsello, M., Vento, G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6554878/
https://www.ncbi.nlm.nih.gov/pubmed/31171028
http://dx.doi.org/10.1186/s13052-019-0663-5
_version_ 1783425040682844160
author Luciano, R.
Mancini, G.
Cota, F.
Romano, A.
Purcaro, V.
Lerro, F.
Corsello, M.
Vento, G.
author_facet Luciano, R.
Mancini, G.
Cota, F.
Romano, A.
Purcaro, V.
Lerro, F.
Corsello, M.
Vento, G.
author_sort Luciano, R.
collection PubMed
description BACKGROUND: Fibreoptic Phototherapy (FPT) allows to lower total serum bilirubin (TSB) levels in healthy neonates maintained in rooming-in with their mothers. The 2004 Cochrane review showed that, differently from preterm neonates, FPT was not as effective as traditional phototherapy in term neonates (TN), unless the simultaneous utilization of two FPT devices. Aim of this study was to compare the efficacy of two FPT devices, both equipped with a single light-emitting diode (LED): the first one has a single large pad wrapped around the infant body (Bilisoft, GE Health Care) (device A), the second one is a double-pad phototherapy device (BiliCocoon, CremascolieIris) (device B). METHODS: We studied 172 healthy neonates with non-hemolytic hyperbilirubinaemia: 57 TN and 57 late preterm neonates (LPN) treated with device A (Group 1); 47 TN and 11 LPN treated with device B (Group 2). We evaluated the differences between groups by the Student’s t-test for continuous variables and by chi square test for categorical data. A two tailed p < 0.05 was considered significant. RESULTS: There were no differences in term of duration of FPT, TSB hourly reduction, percentage of TSB reduction after FPT, TSB maximum rebound, percentage of TSB increase after FPT discontinuation and number of after-discharge checks. Two neonates treated with device B showed no decrease in TSB values during FPT. Seven infants treated with device B experienced hyperpyrexia. CONCLUSIONS: The two LED FPT devices were both effective in lowering TSB either in TN or LPN. Device A was effective in all treated neonates without negative side effects during treatment; device B was effective in all but 2 infants and 12% of the neonates in the same group experienced hyperpyrexia. According to our results, the single big pad wrapped around the infant body has the same efficacy as a double FPT device in TN and LPN.
format Online
Article
Text
id pubmed-6554878
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-65548782019-06-10 New high intensity fibreoptic phototherapy devices in healthy newborns: a single pad wrapped around the neonate body in comparison with a double pad device Luciano, R. Mancini, G. Cota, F. Romano, A. Purcaro, V. Lerro, F. Corsello, M. Vento, G. Ital J Pediatr Research BACKGROUND: Fibreoptic Phototherapy (FPT) allows to lower total serum bilirubin (TSB) levels in healthy neonates maintained in rooming-in with their mothers. The 2004 Cochrane review showed that, differently from preterm neonates, FPT was not as effective as traditional phototherapy in term neonates (TN), unless the simultaneous utilization of two FPT devices. Aim of this study was to compare the efficacy of two FPT devices, both equipped with a single light-emitting diode (LED): the first one has a single large pad wrapped around the infant body (Bilisoft, GE Health Care) (device A), the second one is a double-pad phototherapy device (BiliCocoon, CremascolieIris) (device B). METHODS: We studied 172 healthy neonates with non-hemolytic hyperbilirubinaemia: 57 TN and 57 late preterm neonates (LPN) treated with device A (Group 1); 47 TN and 11 LPN treated with device B (Group 2). We evaluated the differences between groups by the Student’s t-test for continuous variables and by chi square test for categorical data. A two tailed p < 0.05 was considered significant. RESULTS: There were no differences in term of duration of FPT, TSB hourly reduction, percentage of TSB reduction after FPT, TSB maximum rebound, percentage of TSB increase after FPT discontinuation and number of after-discharge checks. Two neonates treated with device B showed no decrease in TSB values during FPT. Seven infants treated with device B experienced hyperpyrexia. CONCLUSIONS: The two LED FPT devices were both effective in lowering TSB either in TN or LPN. Device A was effective in all treated neonates without negative side effects during treatment; device B was effective in all but 2 infants and 12% of the neonates in the same group experienced hyperpyrexia. According to our results, the single big pad wrapped around the infant body has the same efficacy as a double FPT device in TN and LPN. BioMed Central 2019-06-06 /pmc/articles/PMC6554878/ /pubmed/31171028 http://dx.doi.org/10.1186/s13052-019-0663-5 Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Luciano, R.
Mancini, G.
Cota, F.
Romano, A.
Purcaro, V.
Lerro, F.
Corsello, M.
Vento, G.
New high intensity fibreoptic phototherapy devices in healthy newborns: a single pad wrapped around the neonate body in comparison with a double pad device
title New high intensity fibreoptic phototherapy devices in healthy newborns: a single pad wrapped around the neonate body in comparison with a double pad device
title_full New high intensity fibreoptic phototherapy devices in healthy newborns: a single pad wrapped around the neonate body in comparison with a double pad device
title_fullStr New high intensity fibreoptic phototherapy devices in healthy newborns: a single pad wrapped around the neonate body in comparison with a double pad device
title_full_unstemmed New high intensity fibreoptic phototherapy devices in healthy newborns: a single pad wrapped around the neonate body in comparison with a double pad device
title_short New high intensity fibreoptic phototherapy devices in healthy newborns: a single pad wrapped around the neonate body in comparison with a double pad device
title_sort new high intensity fibreoptic phototherapy devices in healthy newborns: a single pad wrapped around the neonate body in comparison with a double pad device
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6554878/
https://www.ncbi.nlm.nih.gov/pubmed/31171028
http://dx.doi.org/10.1186/s13052-019-0663-5
work_keys_str_mv AT lucianor newhighintensityfibreopticphototherapydevicesinhealthynewbornsasinglepadwrappedaroundtheneonatebodyincomparisonwithadoublepaddevice
AT mancinig newhighintensityfibreopticphototherapydevicesinhealthynewbornsasinglepadwrappedaroundtheneonatebodyincomparisonwithadoublepaddevice
AT cotaf newhighintensityfibreopticphototherapydevicesinhealthynewbornsasinglepadwrappedaroundtheneonatebodyincomparisonwithadoublepaddevice
AT romanoa newhighintensityfibreopticphototherapydevicesinhealthynewbornsasinglepadwrappedaroundtheneonatebodyincomparisonwithadoublepaddevice
AT purcarov newhighintensityfibreopticphototherapydevicesinhealthynewbornsasinglepadwrappedaroundtheneonatebodyincomparisonwithadoublepaddevice
AT lerrof newhighintensityfibreopticphototherapydevicesinhealthynewbornsasinglepadwrappedaroundtheneonatebodyincomparisonwithadoublepaddevice
AT corsellom newhighintensityfibreopticphototherapydevicesinhealthynewbornsasinglepadwrappedaroundtheneonatebodyincomparisonwithadoublepaddevice
AT ventog newhighintensityfibreopticphototherapydevicesinhealthynewbornsasinglepadwrappedaroundtheneonatebodyincomparisonwithadoublepaddevice