Cargando…

An In Vitro Evaluation of Fracture Resistance of Endodontically Treated Maxillary Central Incisor Restored with Custom-Made Cast Post and Core with Uniform and Nonuniform Core Ferrule Heights

AIM: The aim of this study was to evaluate in vitro fracture resistance of endodontically treated teeth restored with custom-made cast post and core having uniform and nonuniform core ferrule heights. MATERIALS AND METHODS: Thirty-five freshly extracted human maxillary central incisors were included...

Descripción completa

Detalles Bibliográficos
Autores principales: Elavarasu, Premkumar, Karumaran, Chellaswamy Savarimalai, Indira, Rajamani, Anilkumar, Ramachandran, Mani, Rekha, Natarajan, Raghunathan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6555312/
https://www.ncbi.nlm.nih.gov/pubmed/31198378
http://dx.doi.org/10.4103/JPBS.JPBS_50_19
_version_ 1783425129182658560
author Elavarasu, Premkumar
Karumaran, Chellaswamy Savarimalai
Indira, Rajamani
Anilkumar, Ramachandran
Mani, Rekha
Natarajan, Raghunathan
author_facet Elavarasu, Premkumar
Karumaran, Chellaswamy Savarimalai
Indira, Rajamani
Anilkumar, Ramachandran
Mani, Rekha
Natarajan, Raghunathan
author_sort Elavarasu, Premkumar
collection PubMed
description AIM: The aim of this study was to evaluate in vitro fracture resistance of endodontically treated teeth restored with custom-made cast post and core having uniform and nonuniform core ferrule heights. MATERIALS AND METHODS: Thirty-five freshly extracted human maxillary central incisors were included in this study. All teeth were subjected to standard root canal treatment. The teeth were randomly divided into five groups—Group 1: uniform ferrule (2 mm buccal, lingual, and proximal), Group 2: uniform ferrule (3 mm buccal, lingual, and proximal), Group 3: nonuniform ferrule (2 mm buccal, 3 mm lingual), Group 4: nonuniform ferrule (2 mm buccal, 4 mm lingual), and Group 5: no ferrule. The teeth were sectioned horizontally 4 mm above cementoenamel junction and post space preparation was performed maintaining 4 mm of apical gutta-percha. Ferrule was prepared according to dimension designated for each group. Custom-made cast post and core were fabricated and luted using zinc phosphate cement. Testing was conducted using universal testing machine with application of static load (Newton), and failure load was recorded. Data were analyzed by one-way analysis of variance and Tukey test. The mode of fracture was noted by visual inspection for all specimens. RESULT: Significant differences (P < 0.001) were found among mean fracture forces of test groups. Group 1: 1181.66 ± 68.29, Group 2: 1455.58 ± 173.11, Group 3: 1019.00 ± 52.55, Group 4: 971.58 ± 66.52, and Group 5: 888.00 ± 60.56. The presence of nonuniform ferrule height resulted in a significant decrease (P < 0.0001) in mean fracture strength compared to uniform 2- and 3-mm core ferrule height. CONCLUSION: The central incisors restored with cast post and core and crowns with 3-mm uniform core ferrule were more fracture resistant compared to central incisors with nonuniform core ferrule height. Both the uniform and nonuniform core ferrule groups were more fracture resistant than the group that lacked ferrule.
format Online
Article
Text
id pubmed-6555312
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-65553122019-06-13 An In Vitro Evaluation of Fracture Resistance of Endodontically Treated Maxillary Central Incisor Restored with Custom-Made Cast Post and Core with Uniform and Nonuniform Core Ferrule Heights Elavarasu, Premkumar Karumaran, Chellaswamy Savarimalai Indira, Rajamani Anilkumar, Ramachandran Mani, Rekha Natarajan, Raghunathan J Pharm Bioallied Sci Original Research AIM: The aim of this study was to evaluate in vitro fracture resistance of endodontically treated teeth restored with custom-made cast post and core having uniform and nonuniform core ferrule heights. MATERIALS AND METHODS: Thirty-five freshly extracted human maxillary central incisors were included in this study. All teeth were subjected to standard root canal treatment. The teeth were randomly divided into five groups—Group 1: uniform ferrule (2 mm buccal, lingual, and proximal), Group 2: uniform ferrule (3 mm buccal, lingual, and proximal), Group 3: nonuniform ferrule (2 mm buccal, 3 mm lingual), Group 4: nonuniform ferrule (2 mm buccal, 4 mm lingual), and Group 5: no ferrule. The teeth were sectioned horizontally 4 mm above cementoenamel junction and post space preparation was performed maintaining 4 mm of apical gutta-percha. Ferrule was prepared according to dimension designated for each group. Custom-made cast post and core were fabricated and luted using zinc phosphate cement. Testing was conducted using universal testing machine with application of static load (Newton), and failure load was recorded. Data were analyzed by one-way analysis of variance and Tukey test. The mode of fracture was noted by visual inspection for all specimens. RESULT: Significant differences (P < 0.001) were found among mean fracture forces of test groups. Group 1: 1181.66 ± 68.29, Group 2: 1455.58 ± 173.11, Group 3: 1019.00 ± 52.55, Group 4: 971.58 ± 66.52, and Group 5: 888.00 ± 60.56. The presence of nonuniform ferrule height resulted in a significant decrease (P < 0.0001) in mean fracture strength compared to uniform 2- and 3-mm core ferrule height. CONCLUSION: The central incisors restored with cast post and core and crowns with 3-mm uniform core ferrule were more fracture resistant compared to central incisors with nonuniform core ferrule height. Both the uniform and nonuniform core ferrule groups were more fracture resistant than the group that lacked ferrule. Medknow Publications & Media Pvt Ltd 2019-05 /pmc/articles/PMC6555312/ /pubmed/31198378 http://dx.doi.org/10.4103/JPBS.JPBS_50_19 Text en Copyright: © 2019 Journal of Pharmacy and Bioallied Sciences http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Research
Elavarasu, Premkumar
Karumaran, Chellaswamy Savarimalai
Indira, Rajamani
Anilkumar, Ramachandran
Mani, Rekha
Natarajan, Raghunathan
An In Vitro Evaluation of Fracture Resistance of Endodontically Treated Maxillary Central Incisor Restored with Custom-Made Cast Post and Core with Uniform and Nonuniform Core Ferrule Heights
title An In Vitro Evaluation of Fracture Resistance of Endodontically Treated Maxillary Central Incisor Restored with Custom-Made Cast Post and Core with Uniform and Nonuniform Core Ferrule Heights
title_full An In Vitro Evaluation of Fracture Resistance of Endodontically Treated Maxillary Central Incisor Restored with Custom-Made Cast Post and Core with Uniform and Nonuniform Core Ferrule Heights
title_fullStr An In Vitro Evaluation of Fracture Resistance of Endodontically Treated Maxillary Central Incisor Restored with Custom-Made Cast Post and Core with Uniform and Nonuniform Core Ferrule Heights
title_full_unstemmed An In Vitro Evaluation of Fracture Resistance of Endodontically Treated Maxillary Central Incisor Restored with Custom-Made Cast Post and Core with Uniform and Nonuniform Core Ferrule Heights
title_short An In Vitro Evaluation of Fracture Resistance of Endodontically Treated Maxillary Central Incisor Restored with Custom-Made Cast Post and Core with Uniform and Nonuniform Core Ferrule Heights
title_sort in vitro evaluation of fracture resistance of endodontically treated maxillary central incisor restored with custom-made cast post and core with uniform and nonuniform core ferrule heights
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6555312/
https://www.ncbi.nlm.nih.gov/pubmed/31198378
http://dx.doi.org/10.4103/JPBS.JPBS_50_19
work_keys_str_mv AT elavarasupremkumar aninvitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT karumaranchellaswamysavarimalai aninvitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT indirarajamani aninvitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT anilkumarramachandran aninvitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT manirekha aninvitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT natarajanraghunathan aninvitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT elavarasupremkumar invitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT karumaranchellaswamysavarimalai invitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT indirarajamani invitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT anilkumarramachandran invitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT manirekha invitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights
AT natarajanraghunathan invitroevaluationoffractureresistanceofendodonticallytreatedmaxillarycentralincisorrestoredwithcustommadecastpostandcorewithuniformandnonuniformcoreferruleheights