Comparative Evaluation of Implant Designs: Influence of Diameter, Length, and Taper on Stress and Strain in the Mandibular Segment—A Three-Dimensional Finite Element Analysis
INTRODUCTION: Success or failure of dental implants depends on the amount of stress transferred to the surrounding bone. Increased amount of loading to the bone through implant cause failure, whereas decrease in the amount of loading to the bone causes improved success rate of implants. Biomechanica...
Autores principales: | Raaj, Gowthama, Manimaran, Pulliappan, Kumar, Chandran Dhinesh, Sadan, Duraisamy Sai, Abirami, Mathivanan |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6555380/ https://www.ncbi.nlm.nih.gov/pubmed/31198367 http://dx.doi.org/10.4103/JPBS.JPBS_29_19 |
Ejemplares similares
-
Evaluation of Efficiency of Different Decontamination Methods of Dental Burs: An In vivo Study
por: Mathivanan, Abirami, et al.
Publicado: (2017) -
Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis
por: Xing, Zhang, et al.
Publicado: (2017) -
Morse taper performance: A finite element analysis study
por: Petris, Gustavo Passarelli, et al.
Publicado: (2019) -
Pure Mandibular Incisor Intrusion: A Finite Element Study to Evaluate the Segmented Arch Technique
por: de Brito, Gabriela Meyge, et al.
Publicado: (2019) -
Impact of Screw Diameter and Length on Pedicle Screw Fixation Strength in Osteoporotic Vertebrae: A Finite Element Analysis
por: Matsukawa, Keitaro, et al.
Publicado: (2021)