Cargando…
The value of 3D visualization operative planning system in ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas: a clinical comparative study
BACKGROUND: To evaluate the value of a three dimension (3D)visualization operative planning system in ultrasound-guided percutaneous microwave ablation (US-PMWA) for large hepatic hemangiomas (LHHs). METHODS: Fifty-eight patients with LHHs were divided into 3D and 2D groups. The therapeutic efficacy...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6555953/ https://www.ncbi.nlm.nih.gov/pubmed/31174503 http://dx.doi.org/10.1186/s12885-019-5682-5 |
_version_ | 1783425243408236544 |
---|---|
author | Li, Xin An, Chao Liu, Fangyi Cheng, Zhigang Han, Zhiyu Yu, Xiaoling Dong, Linan Yu, Jie Liang, Ping |
author_facet | Li, Xin An, Chao Liu, Fangyi Cheng, Zhigang Han, Zhiyu Yu, Xiaoling Dong, Linan Yu, Jie Liang, Ping |
author_sort | Li, Xin |
collection | PubMed |
description | BACKGROUND: To evaluate the value of a three dimension (3D)visualization operative planning system in ultrasound-guided percutaneous microwave ablation (US-PMWA) for large hepatic hemangiomas (LHHs). METHODS: Fifty-eight patients with LHHs were divided into 3D and 2D groups. The therapeutic efficacy was assessed by contrast-enhanced imaging during follow-up. Hepatic and renal function were examined. The complete ablation, tumor volume shrinkage, and complication rates were analyzed. RESULTS: The ablation time and energy of the 3D group were lower than those of the 2D group (1152.0 ± 403.9 s vs. 1379.7 ± 375.8 s and 87,407.2.9 ± 50,387.0 J vs. 117,775.8 ± 46,245.6 J, P = 0.031 and 0.021, respectively). The 3D group had a higher complete ablation rate than the 2D group (97.7 ± 2.4% vs. 94.5 ± 3.7%, P < 0.001). The incidence of hemoglobinuria after ablation in the 3D group was lower than that in the 2D group (32.0% vs. 57.6%, P = 0.047). The levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), and creatinine (Cre) after ablation in the 3D group were lower than those in the 2D group (126.7 ± 56.4 U/L vs. 210.9 ± 96.2 U/L, P < 0.001; 141.0 ± 60.8 U/L vs. 211.4 ± 90.0 U/L, P = 0.001; 57.3 ± 17.6 U/L vs. 80.8 ± 41.9 U/L, P = 0.010; and 66.6 ± 16.6 mmol/L vs. 84.5 ± 39.6 mmol/L, P = 0.037, respectively). There were no significant differences in antenna insertion and the volume reduction rate between the groups. One patient developed acute kidney injury shortly after ablation in the 2D group and recovered after hemodialysis. No other severe complications occurred during the follow-up period. CONCLUSIONS: The 3D visualization operative planning system has a relatively high clinical application value in providing scientific, reasonable, quantifiable, and individualized therapy for LHHs by US-PMWA. |
format | Online Article Text |
id | pubmed-6555953 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-65559532019-06-10 The value of 3D visualization operative planning system in ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas: a clinical comparative study Li, Xin An, Chao Liu, Fangyi Cheng, Zhigang Han, Zhiyu Yu, Xiaoling Dong, Linan Yu, Jie Liang, Ping BMC Cancer Research Article BACKGROUND: To evaluate the value of a three dimension (3D)visualization operative planning system in ultrasound-guided percutaneous microwave ablation (US-PMWA) for large hepatic hemangiomas (LHHs). METHODS: Fifty-eight patients with LHHs were divided into 3D and 2D groups. The therapeutic efficacy was assessed by contrast-enhanced imaging during follow-up. Hepatic and renal function were examined. The complete ablation, tumor volume shrinkage, and complication rates were analyzed. RESULTS: The ablation time and energy of the 3D group were lower than those of the 2D group (1152.0 ± 403.9 s vs. 1379.7 ± 375.8 s and 87,407.2.9 ± 50,387.0 J vs. 117,775.8 ± 46,245.6 J, P = 0.031 and 0.021, respectively). The 3D group had a higher complete ablation rate than the 2D group (97.7 ± 2.4% vs. 94.5 ± 3.7%, P < 0.001). The incidence of hemoglobinuria after ablation in the 3D group was lower than that in the 2D group (32.0% vs. 57.6%, P = 0.047). The levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), and creatinine (Cre) after ablation in the 3D group were lower than those in the 2D group (126.7 ± 56.4 U/L vs. 210.9 ± 96.2 U/L, P < 0.001; 141.0 ± 60.8 U/L vs. 211.4 ± 90.0 U/L, P = 0.001; 57.3 ± 17.6 U/L vs. 80.8 ± 41.9 U/L, P = 0.010; and 66.6 ± 16.6 mmol/L vs. 84.5 ± 39.6 mmol/L, P = 0.037, respectively). There were no significant differences in antenna insertion and the volume reduction rate between the groups. One patient developed acute kidney injury shortly after ablation in the 2D group and recovered after hemodialysis. No other severe complications occurred during the follow-up period. CONCLUSIONS: The 3D visualization operative planning system has a relatively high clinical application value in providing scientific, reasonable, quantifiable, and individualized therapy for LHHs by US-PMWA. BioMed Central 2019-06-07 /pmc/articles/PMC6555953/ /pubmed/31174503 http://dx.doi.org/10.1186/s12885-019-5682-5 Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Li, Xin An, Chao Liu, Fangyi Cheng, Zhigang Han, Zhiyu Yu, Xiaoling Dong, Linan Yu, Jie Liang, Ping The value of 3D visualization operative planning system in ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas: a clinical comparative study |
title | The value of 3D visualization operative planning system in ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas: a clinical comparative study |
title_full | The value of 3D visualization operative planning system in ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas: a clinical comparative study |
title_fullStr | The value of 3D visualization operative planning system in ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas: a clinical comparative study |
title_full_unstemmed | The value of 3D visualization operative planning system in ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas: a clinical comparative study |
title_short | The value of 3D visualization operative planning system in ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas: a clinical comparative study |
title_sort | value of 3d visualization operative planning system in ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas: a clinical comparative study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6555953/ https://www.ncbi.nlm.nih.gov/pubmed/31174503 http://dx.doi.org/10.1186/s12885-019-5682-5 |
work_keys_str_mv | AT lixin thevalueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT anchao thevalueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT liufangyi thevalueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT chengzhigang thevalueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT hanzhiyu thevalueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT yuxiaoling thevalueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT donglinan thevalueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT yujie thevalueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT liangping thevalueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT lixin valueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT anchao valueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT liufangyi valueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT chengzhigang valueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT hanzhiyu valueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT yuxiaoling valueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT donglinan valueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT yujie valueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy AT liangping valueof3dvisualizationoperativeplanningsysteminultrasoundguidedpercutaneousmicrowaveablationforlargehepatichemangiomasaclinicalcomparativestudy |