Cargando…
Use of the autologous spiral vein graft: a two-stage iliac bypass in a potentially fatal case of pelvic trauma and contaminated tissues
Serious problems may be encountered in arterial or venous reconstruction in cases of severe trauma and contaminated tissues. We report the use of a spiral venous graft (SVG) in a case of two-stage bypass aimed at saving first life, and then the extremity. Severe open and contaminated injury was pres...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nagoya University
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6556462/ https://www.ncbi.nlm.nih.gov/pubmed/31239601 http://dx.doi.org/10.18999/nagjms.81.2.331 |
_version_ | 1783425329735401472 |
---|---|
author | Altun, Gokalp Pulathan, Zerrin Hemsinli, Dogus |
author_facet | Altun, Gokalp Pulathan, Zerrin Hemsinli, Dogus |
author_sort | Altun, Gokalp |
collection | PubMed |
description | Serious problems may be encountered in arterial or venous reconstruction in cases of severe trauma and contaminated tissues. We report the use of a spiral venous graft (SVG) in a case of two-stage bypass aimed at saving first life, and then the extremity. Severe open and contaminated injury was present in the lower abdomen and pelvic region of 29-year-old woman brought to the emergency department following a traffic accident. The patient was in shock, and was taken for emergency surgery jointly with the relevant departments. Interposition bypasses with synthetic graft were performed in the first stage. The synthetic grafts were subsequently removed due to problems developing secondary to infection at subsequent follow-up, and revascularization was established with autologous grafts together with SVG. SVGs are alternative grafts in cases with contaminated tissues and requiring major vessel reconstruction. This technique can add to the therapeutic options available. |
format | Online Article Text |
id | pubmed-6556462 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nagoya University |
record_format | MEDLINE/PubMed |
spelling | pubmed-65564622019-06-25 Use of the autologous spiral vein graft: a two-stage iliac bypass in a potentially fatal case of pelvic trauma and contaminated tissues Altun, Gokalp Pulathan, Zerrin Hemsinli, Dogus Nagoya J Med Sci Case Report Serious problems may be encountered in arterial or venous reconstruction in cases of severe trauma and contaminated tissues. We report the use of a spiral venous graft (SVG) in a case of two-stage bypass aimed at saving first life, and then the extremity. Severe open and contaminated injury was present in the lower abdomen and pelvic region of 29-year-old woman brought to the emergency department following a traffic accident. The patient was in shock, and was taken for emergency surgery jointly with the relevant departments. Interposition bypasses with synthetic graft were performed in the first stage. The synthetic grafts were subsequently removed due to problems developing secondary to infection at subsequent follow-up, and revascularization was established with autologous grafts together with SVG. SVGs are alternative grafts in cases with contaminated tissues and requiring major vessel reconstruction. This technique can add to the therapeutic options available. Nagoya University 2019-05 /pmc/articles/PMC6556462/ /pubmed/31239601 http://dx.doi.org/10.18999/nagjms.81.2.331 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Altun, Gokalp Pulathan, Zerrin Hemsinli, Dogus Use of the autologous spiral vein graft: a two-stage iliac bypass in a potentially fatal case of pelvic trauma and contaminated tissues |
title | Use of the autologous spiral vein graft: a two-stage iliac bypass in a potentially fatal case of pelvic trauma and contaminated tissues |
title_full | Use of the autologous spiral vein graft: a two-stage iliac bypass in a potentially fatal case of pelvic trauma and contaminated tissues |
title_fullStr | Use of the autologous spiral vein graft: a two-stage iliac bypass in a potentially fatal case of pelvic trauma and contaminated tissues |
title_full_unstemmed | Use of the autologous spiral vein graft: a two-stage iliac bypass in a potentially fatal case of pelvic trauma and contaminated tissues |
title_short | Use of the autologous spiral vein graft: a two-stage iliac bypass in a potentially fatal case of pelvic trauma and contaminated tissues |
title_sort | use of the autologous spiral vein graft: a two-stage iliac bypass in a potentially fatal case of pelvic trauma and contaminated tissues |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6556462/ https://www.ncbi.nlm.nih.gov/pubmed/31239601 http://dx.doi.org/10.18999/nagjms.81.2.331 |
work_keys_str_mv | AT altungokalp useoftheautologousspiralveingraftatwostageiliacbypassinapotentiallyfatalcaseofpelvictraumaandcontaminatedtissues AT pulathanzerrin useoftheautologousspiralveingraftatwostageiliacbypassinapotentiallyfatalcaseofpelvictraumaandcontaminatedtissues AT hemsinlidogus useoftheautologousspiralveingraftatwostageiliacbypassinapotentiallyfatalcaseofpelvictraumaandcontaminatedtissues |