Cargando…

Semi-permanent smartphone adapter for microscopes: Design demonstration and workflow testing using a slit-lamp biomicroscope

BACKGROUND: A smartphone microscope adapter is an alternative to a permanently mounted camera, which often requires a specially designed light path as well as a computer system for data storage and network connectivity. A common disadvantage of these adapters is that they need to be repeatedly mount...

Descripción completa

Detalles Bibliográficos
Autores principales: Yen, Chieh-Hung, Wang, Guo-Quan, Lin, Tommy Y., Liu, Chun-Hsiu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6557070/
https://www.ncbi.nlm.nih.gov/pubmed/31198670
http://dx.doi.org/10.4103/tjo.tjo_19_18
_version_ 1783425417417326592
author Yen, Chieh-Hung
Wang, Guo-Quan
Lin, Tommy Y.
Liu, Chun-Hsiu
author_facet Yen, Chieh-Hung
Wang, Guo-Quan
Lin, Tommy Y.
Liu, Chun-Hsiu
author_sort Yen, Chieh-Hung
collection PubMed
description BACKGROUND: A smartphone microscope adapter is an alternative to a permanently mounted camera, which often requires a specially designed light path as well as a computer system for data storage and network connectivity. A common disadvantage of these adapters is that they need to be repeatedly mounted and dismounted; this is inconvenient during serial observations. PURPOSE: The study purpose is to develop and test a semi-permanent microscope adapter. METHODS: Our prototype was designed using three-dimensional (3D) computer-aided design software and was 3D printed for testing. Two tests were designed to quantify the workflow improvement by measuring the time required to complete specific movements, which simulated the actions of capturing photographs by using an adapter and a slit-lamp biomicroscope. Our prototype was the experimental adapter, and two commercially available products were used as references. A single-shot test measured the average time required to complete a photographing cycle, in which a single photograph was recorded. A multiple-shot test measured the time required to complete cycles in which a different number of photographs were captured; thus, the time required specifically for the preparation phase of photographing was determined. Both tests were performed by 4 researchers. RESULTS: The average time required to complete a cycle using our prototype in single-shot test was significantly shorter than that using one of the references. For the other reference, significances were shown in 2 testers’ results. In the multiple-shot test, the linear regression analysis also showed that the preparation phase of our prototype was significantly shorter than the preparation phase of the two commercially available products (P < 0.001). CONCLUSIONS: The semi-permanent design may improve the workflow of photography using smartphone adapters, thereby reducing the time and effort required for preparing devices, particularly when making multiple consecutive observations or when the targets disappear fast.
format Online
Article
Text
id pubmed-6557070
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-65570702019-06-13 Semi-permanent smartphone adapter for microscopes: Design demonstration and workflow testing using a slit-lamp biomicroscope Yen, Chieh-Hung Wang, Guo-Quan Lin, Tommy Y. Liu, Chun-Hsiu Taiwan J Ophthalmol Original Article BACKGROUND: A smartphone microscope adapter is an alternative to a permanently mounted camera, which often requires a specially designed light path as well as a computer system for data storage and network connectivity. A common disadvantage of these adapters is that they need to be repeatedly mounted and dismounted; this is inconvenient during serial observations. PURPOSE: The study purpose is to develop and test a semi-permanent microscope adapter. METHODS: Our prototype was designed using three-dimensional (3D) computer-aided design software and was 3D printed for testing. Two tests were designed to quantify the workflow improvement by measuring the time required to complete specific movements, which simulated the actions of capturing photographs by using an adapter and a slit-lamp biomicroscope. Our prototype was the experimental adapter, and two commercially available products were used as references. A single-shot test measured the average time required to complete a photographing cycle, in which a single photograph was recorded. A multiple-shot test measured the time required to complete cycles in which a different number of photographs were captured; thus, the time required specifically for the preparation phase of photographing was determined. Both tests were performed by 4 researchers. RESULTS: The average time required to complete a cycle using our prototype in single-shot test was significantly shorter than that using one of the references. For the other reference, significances were shown in 2 testers’ results. In the multiple-shot test, the linear regression analysis also showed that the preparation phase of our prototype was significantly shorter than the preparation phase of the two commercially available products (P < 0.001). CONCLUSIONS: The semi-permanent design may improve the workflow of photography using smartphone adapters, thereby reducing the time and effort required for preparing devices, particularly when making multiple consecutive observations or when the targets disappear fast. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC6557070/ /pubmed/31198670 http://dx.doi.org/10.4103/tjo.tjo_19_18 Text en Copyright: © 2019 Taiwan J Ophthalmol http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Yen, Chieh-Hung
Wang, Guo-Quan
Lin, Tommy Y.
Liu, Chun-Hsiu
Semi-permanent smartphone adapter for microscopes: Design demonstration and workflow testing using a slit-lamp biomicroscope
title Semi-permanent smartphone adapter for microscopes: Design demonstration and workflow testing using a slit-lamp biomicroscope
title_full Semi-permanent smartphone adapter for microscopes: Design demonstration and workflow testing using a slit-lamp biomicroscope
title_fullStr Semi-permanent smartphone adapter for microscopes: Design demonstration and workflow testing using a slit-lamp biomicroscope
title_full_unstemmed Semi-permanent smartphone adapter for microscopes: Design demonstration and workflow testing using a slit-lamp biomicroscope
title_short Semi-permanent smartphone adapter for microscopes: Design demonstration and workflow testing using a slit-lamp biomicroscope
title_sort semi-permanent smartphone adapter for microscopes: design demonstration and workflow testing using a slit-lamp biomicroscope
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6557070/
https://www.ncbi.nlm.nih.gov/pubmed/31198670
http://dx.doi.org/10.4103/tjo.tjo_19_18
work_keys_str_mv AT yenchiehhung semipermanentsmartphoneadapterformicroscopesdesigndemonstrationandworkflowtestingusingaslitlampbiomicroscope
AT wangguoquan semipermanentsmartphoneadapterformicroscopesdesigndemonstrationandworkflowtestingusingaslitlampbiomicroscope
AT lintommyy semipermanentsmartphoneadapterformicroscopesdesigndemonstrationandworkflowtestingusingaslitlampbiomicroscope
AT liuchunhsiu semipermanentsmartphoneadapterformicroscopesdesigndemonstrationandworkflowtestingusingaslitlampbiomicroscope