Cargando…
Precision pulse capsulotomy: an automated alternative to manual capsulorhexis in paediatric cataract
OBJECTIVE: To report our operative experience with precision pulse capsulotomy (PPC) for anterior capsulotomy in a paediatric cataract series. METHODS AND ANALYSIS: This study is a retrospective interventional, descriptive series of consecutive paediatric eyes (≤16 years) undergoing cataract surgery...
Autores principales: | Chougule, Pratik, Warkad, Vivekanand, Badakere, Akshay, Kekunnaya, Ramesh |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6557080/ https://www.ncbi.nlm.nih.gov/pubmed/31245610 http://dx.doi.org/10.1136/bmjophth-2018-000255 |
Ejemplares similares
-
Commentary: Precision pulse capsulotomy: New technology for capsulorhexis
por: Dudeja, Lakshey
Publicado: (2018) -
Endothelial Cell Loss Following Cataract Surgery Using Continuous Curvilinear Capsulorhexis or Precision Pulse Capsulotomy
por: Vital, Mark C, et al.
Publicado: (2023) -
Different strokes for anterior capsulorhexis in pediatric cataract
por: Chattannavar, Goura, et al.
Publicado: (2023) -
Clinical profile, diagnostic challenges, and outcomes in subacute/chronic cerebral sinus venous thrombosis
por: Sachdeva, Virender, et al.
Publicado: (2021) -
Precision pulse capsulotomy in challenging cataract surgery cases
por: Park, Min Ji, et al.
Publicado: (2019)