Cargando…

Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation

PURPOSE: To investigate the clinical features and surgical outcomes of encapsulated bleb excision with collagen matrix implantation performed in patients with failed Ahmed glaucoma valve (AGV) implantation. METHODS: Eighteen eyes of 18 patients underwent encapsulated bleb excision and collagen matri...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Seong Eun, Kim, Kyoung Nam, Kim, Woo-Jin, Lee, Sung Bok, Kim, Chang-sik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6557799/
https://www.ncbi.nlm.nih.gov/pubmed/31179652
http://dx.doi.org/10.3341/kjo.2018.0110
_version_ 1783425496006000640
author Lee, Seong Eun
Kim, Kyoung Nam
Kim, Woo-Jin
Lee, Sung Bok
Kim, Chang-sik
author_facet Lee, Seong Eun
Kim, Kyoung Nam
Kim, Woo-Jin
Lee, Sung Bok
Kim, Chang-sik
author_sort Lee, Seong Eun
collection PubMed
description PURPOSE: To investigate the clinical features and surgical outcomes of encapsulated bleb excision with collagen matrix implantation performed in patients with failed Ahmed glaucoma valve (AGV) implantation. METHODS: Eighteen eyes of 18 patients underwent encapsulated bleb excision and collagen matrix implantation. Patients were divided into two groups by reference to intraocular pressure (IOP) after preoperative ocular massage: group 1, patients who exhibited substantial IOP reductions; and group 2, patients who did not show substantial changes in IOP. Needling was conducted in group 2. The clinical features of the two groups were compared, including IOP changes after ocular massage and needling, AGV status, and surgical outcomes 6 months after surgery. RESULTS: The mean preoperative IOP among the 18 patients was 30.6 ± 5.7 mmHg. After ocular massage, the IOPs decreased by 22 and 26 mmHg in the two patients in group 1 and the 16 patients in group 2 showed a mean IOP reduction of 1.6 ± 2.2 mmHg (p = 0.013). IOPs decreased after needling in group 2 (range, 6 to 30 mmHg; p < 0.001). Fibrovascular tissue ingrowth into the AGV was observed in the two patients in group 1 and the same ingrowth was observed in 10 of the 16 patients in group 2. Six months after surgery the mean IOP among the 18 patients decreased significantly (19.1 ± 3.2 mmHg, p < 0.001). There was no significant difference in the mean postoperative IOP at 6 months between group 1 (14.0 ± 2.8 mmHg) and group 2 (19.8 ± 2.6 mmHg, p = 0.052). CONCLUSIONS: Encapsulated bleb excision with collagen matrix implantation resulted in a significant IOP-lowering effect 6 months after surgery. Fibrovascular ingrowth into the AGV was common but did not seem to be a major cause of AGV implantation failure.
format Online
Article
Text
id pubmed-6557799
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-65577992019-06-20 Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation Lee, Seong Eun Kim, Kyoung Nam Kim, Woo-Jin Lee, Sung Bok Kim, Chang-sik Korean J Ophthalmol Original Article PURPOSE: To investigate the clinical features and surgical outcomes of encapsulated bleb excision with collagen matrix implantation performed in patients with failed Ahmed glaucoma valve (AGV) implantation. METHODS: Eighteen eyes of 18 patients underwent encapsulated bleb excision and collagen matrix implantation. Patients were divided into two groups by reference to intraocular pressure (IOP) after preoperative ocular massage: group 1, patients who exhibited substantial IOP reductions; and group 2, patients who did not show substantial changes in IOP. Needling was conducted in group 2. The clinical features of the two groups were compared, including IOP changes after ocular massage and needling, AGV status, and surgical outcomes 6 months after surgery. RESULTS: The mean preoperative IOP among the 18 patients was 30.6 ± 5.7 mmHg. After ocular massage, the IOPs decreased by 22 and 26 mmHg in the two patients in group 1 and the 16 patients in group 2 showed a mean IOP reduction of 1.6 ± 2.2 mmHg (p = 0.013). IOPs decreased after needling in group 2 (range, 6 to 30 mmHg; p < 0.001). Fibrovascular tissue ingrowth into the AGV was observed in the two patients in group 1 and the same ingrowth was observed in 10 of the 16 patients in group 2. Six months after surgery the mean IOP among the 18 patients decreased significantly (19.1 ± 3.2 mmHg, p < 0.001). There was no significant difference in the mean postoperative IOP at 6 months between group 1 (14.0 ± 2.8 mmHg) and group 2 (19.8 ± 2.6 mmHg, p = 0.052). CONCLUSIONS: Encapsulated bleb excision with collagen matrix implantation resulted in a significant IOP-lowering effect 6 months after surgery. Fibrovascular ingrowth into the AGV was common but did not seem to be a major cause of AGV implantation failure. The Korean Ophthalmological Society 2019-06 2019-06-04 /pmc/articles/PMC6557799/ /pubmed/31179652 http://dx.doi.org/10.3341/kjo.2018.0110 Text en © 2019 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Seong Eun
Kim, Kyoung Nam
Kim, Woo-Jin
Lee, Sung Bok
Kim, Chang-sik
Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation
title Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation
title_full Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation
title_fullStr Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation
title_full_unstemmed Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation
title_short Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation
title_sort encapsulated bleb excision with collagen matrix implantation following failed ahmed glaucoma valve implantation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6557799/
https://www.ncbi.nlm.nih.gov/pubmed/31179652
http://dx.doi.org/10.3341/kjo.2018.0110
work_keys_str_mv AT leeseongeun encapsulatedblebexcisionwithcollagenmatriximplantationfollowingfailedahmedglaucomavalveimplantation
AT kimkyoungnam encapsulatedblebexcisionwithcollagenmatriximplantationfollowingfailedahmedglaucomavalveimplantation
AT kimwoojin encapsulatedblebexcisionwithcollagenmatriximplantationfollowingfailedahmedglaucomavalveimplantation
AT leesungbok encapsulatedblebexcisionwithcollagenmatriximplantationfollowingfailedahmedglaucomavalveimplantation
AT kimchangsik encapsulatedblebexcisionwithcollagenmatriximplantationfollowingfailedahmedglaucomavalveimplantation