Development of a rotational set‐up correction device for stereotactic head radiation therapy: A performance evaluation

We developed a new head supporting device to provide accurate correction of rotational setup during image‐guided radiation therapy (IGRT), evaluating its correction performance and the efficacy of dose distribution in stereotactic radiotherapy (SRT) using a helical tomotherapy (HT) system. The accur...

Descripción completa

Detalles Bibliográficos
Autores principales: Usui, Keisuke, Isobe, Akira, Hara, Naoya, Muroi, Tomoya, Sajiki, Osamu, Ogawa, Koichi, Shikama, Naoto, Sasai, Keisuke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6560248/
https://www.ncbi.nlm.nih.gov/pubmed/31112364
http://dx.doi.org/10.1002/acm2.12616
_version_ 1783425934015070208
author Usui, Keisuke
Isobe, Akira
Hara, Naoya
Muroi, Tomoya
Sajiki, Osamu
Ogawa, Koichi
Shikama, Naoto
Sasai, Keisuke
author_facet Usui, Keisuke
Isobe, Akira
Hara, Naoya
Muroi, Tomoya
Sajiki, Osamu
Ogawa, Koichi
Shikama, Naoto
Sasai, Keisuke
author_sort Usui, Keisuke
collection PubMed
description We developed a new head supporting device to provide accurate correction of rotational setup during image‐guided radiation therapy (IGRT), evaluating its correction performance and the efficacy of dose distribution in stereotactic radiotherapy (SRT) using a helical tomotherapy (HT) system. The accuracy of rotational motion was measured using an electronic inclinometer; we compared device angles and measurement values from 0.0° to 3.0°. The correction accuracy was investigated based on the distance between rotational centers in the device and on megavoltage computed tomography (MVCT); the correction values were compared using distances in the range of 0.0–9.0 cm using a head phantom with a rotational error of 1.5°. For an SRT with a simultaneous integrated boost plan and a rotational error of 3.0° in yaw angle using a head phantom, and for a single‐isocenter SRT for multiple brain metastases in the data of three patients, dosimetric efficacy of the HT unit was evaluated for calculated dose distributions with MVCT after rotational correction. This device can correct pitch and yaw angles within 0.3° and can be corrected to within 0.5° for each rotational angle according to the result of MVCT correction regardless of the rotational center position. In the head phantom study, the device had a beneficial impact on rotational correction; D99% for the target improved by approximately 10% with rotational correction. Using patient data with the device, the mean difference based on the treatment planning data was 0.3% for D99% and −0.1% for coverage index to the target. Our rotational setup correction device has high efficacy, and can be used for IGRT.
format Online
Article
Text
id pubmed-6560248
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-65602482019-06-17 Development of a rotational set‐up correction device for stereotactic head radiation therapy: A performance evaluation Usui, Keisuke Isobe, Akira Hara, Naoya Muroi, Tomoya Sajiki, Osamu Ogawa, Koichi Shikama, Naoto Sasai, Keisuke J Appl Clin Med Phys Technical Notes We developed a new head supporting device to provide accurate correction of rotational setup during image‐guided radiation therapy (IGRT), evaluating its correction performance and the efficacy of dose distribution in stereotactic radiotherapy (SRT) using a helical tomotherapy (HT) system. The accuracy of rotational motion was measured using an electronic inclinometer; we compared device angles and measurement values from 0.0° to 3.0°. The correction accuracy was investigated based on the distance between rotational centers in the device and on megavoltage computed tomography (MVCT); the correction values were compared using distances in the range of 0.0–9.0 cm using a head phantom with a rotational error of 1.5°. For an SRT with a simultaneous integrated boost plan and a rotational error of 3.0° in yaw angle using a head phantom, and for a single‐isocenter SRT for multiple brain metastases in the data of three patients, dosimetric efficacy of the HT unit was evaluated for calculated dose distributions with MVCT after rotational correction. This device can correct pitch and yaw angles within 0.3° and can be corrected to within 0.5° for each rotational angle according to the result of MVCT correction regardless of the rotational center position. In the head phantom study, the device had a beneficial impact on rotational correction; D99% for the target improved by approximately 10% with rotational correction. Using patient data with the device, the mean difference based on the treatment planning data was 0.3% for D99% and −0.1% for coverage index to the target. Our rotational setup correction device has high efficacy, and can be used for IGRT. John Wiley and Sons Inc. 2019-05-21 /pmc/articles/PMC6560248/ /pubmed/31112364 http://dx.doi.org/10.1002/acm2.12616 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Usui, Keisuke
Isobe, Akira
Hara, Naoya
Muroi, Tomoya
Sajiki, Osamu
Ogawa, Koichi
Shikama, Naoto
Sasai, Keisuke
Development of a rotational set‐up correction device for stereotactic head radiation therapy: A performance evaluation
title Development of a rotational set‐up correction device for stereotactic head radiation therapy: A performance evaluation
title_full Development of a rotational set‐up correction device for stereotactic head radiation therapy: A performance evaluation
title_fullStr Development of a rotational set‐up correction device for stereotactic head radiation therapy: A performance evaluation
title_full_unstemmed Development of a rotational set‐up correction device for stereotactic head radiation therapy: A performance evaluation
title_short Development of a rotational set‐up correction device for stereotactic head radiation therapy: A performance evaluation
title_sort development of a rotational set‐up correction device for stereotactic head radiation therapy: a performance evaluation
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6560248/
https://www.ncbi.nlm.nih.gov/pubmed/31112364
http://dx.doi.org/10.1002/acm2.12616
work_keys_str_mv AT usuikeisuke developmentofarotationalsetupcorrectiondeviceforstereotacticheadradiationtherapyaperformanceevaluation
AT isobeakira developmentofarotationalsetupcorrectiondeviceforstereotacticheadradiationtherapyaperformanceevaluation
AT haranaoya developmentofarotationalsetupcorrectiondeviceforstereotacticheadradiationtherapyaperformanceevaluation
AT muroitomoya developmentofarotationalsetupcorrectiondeviceforstereotacticheadradiationtherapyaperformanceevaluation
AT sajikiosamu developmentofarotationalsetupcorrectiondeviceforstereotacticheadradiationtherapyaperformanceevaluation
AT ogawakoichi developmentofarotationalsetupcorrectiondeviceforstereotacticheadradiationtherapyaperformanceevaluation
AT shikamanaoto developmentofarotationalsetupcorrectiondeviceforstereotacticheadradiationtherapyaperformanceevaluation
AT sasaikeisuke developmentofarotationalsetupcorrectiondeviceforstereotacticheadradiationtherapyaperformanceevaluation