Reliability of Spectral-Domain OCT Ellipsoid Zone Area and Shape Measurements in Retinitis Pigmentosa

PURPOSE: We investigate the ellipsoid zone (EZ) area and EZ boundary shape measurement reliability and the operability characteristics of two methods of EZ boundary delineation in spectral-domain optical coherence tomography (SD-OCT). METHODS: EZ boundaries in SD-OCT scans of 122 eyes from 64 subjec...

Descripción completa

Detalles Bibliográficos
Autores principales: Smith, Travis B., Parker, Maria A., Steinkamp, Peter N., Romo, Albert, Erker, Laura R., Lujan, Brandon J., Smith, Ning
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6561133/
https://www.ncbi.nlm.nih.gov/pubmed/31211002
http://dx.doi.org/10.1167/tvst.8.3.37
_version_ 1783426089448636416
author Smith, Travis B.
Parker, Maria A.
Steinkamp, Peter N.
Romo, Albert
Erker, Laura R.
Lujan, Brandon J.
Smith, Ning
author_facet Smith, Travis B.
Parker, Maria A.
Steinkamp, Peter N.
Romo, Albert
Erker, Laura R.
Lujan, Brandon J.
Smith, Ning
author_sort Smith, Travis B.
collection PubMed
description PURPOSE: We investigate the ellipsoid zone (EZ) area and EZ boundary shape measurement reliability and the operability characteristics of two methods of EZ boundary delineation in spectral-domain optical coherence tomography (SD-OCT). METHODS: EZ boundaries in SD-OCT scans of 122 eyes from 64 subjects with autosomal dominant retinitis pigmentosa were delineated by three raters using two methods, termed the profile and en face methods. For each method, we determined the measurement reliabilities for boundary area (EZ area) and boundary shape, percentage of eyes with measurable EZ (measurability), time required, and effect of rater experience. RESULTS: With expert raters, inter- and intrarater area intraclass correlation coefficients (ICCs) were 0.986 and 0.980 (profile) and 0.959 and 0.976 (en face), respectively. In comparison, the corresponding shape ICCs were 0.906 and 0.891 (profile) and 0.845 and 0.885 (en face), indicating lower reliability for the raw measurements (P ≤ 0.01). Only profile method interrater reliability depended on experience. Average measurement times per eye were 8.2 (profile) and 4.1 (en face) minutes. Measurability percentages were 99.2% (profile) and 73.0% (en face). CONCLUSIONS: The slower profile method had better measurability, and with expert raters yielded the best area and shape reliabilities. The faster, but less sensitive, en face method still showed excellent reliability, and was less dependent on experience. Shape analysis reveals the boundary measurements underpinning EZ area have lower reliability than suggested by area analysis. TRANSLATIONAL RELEVANCE: This study provides new reliability perspectives and logistical considerations for the manual measurement procedures that generate EZ area outcome measures.
format Online
Article
Text
id pubmed-6561133
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-65611332019-06-17 Reliability of Spectral-Domain OCT Ellipsoid Zone Area and Shape Measurements in Retinitis Pigmentosa Smith, Travis B. Parker, Maria A. Steinkamp, Peter N. Romo, Albert Erker, Laura R. Lujan, Brandon J. Smith, Ning Transl Vis Sci Technol Articles PURPOSE: We investigate the ellipsoid zone (EZ) area and EZ boundary shape measurement reliability and the operability characteristics of two methods of EZ boundary delineation in spectral-domain optical coherence tomography (SD-OCT). METHODS: EZ boundaries in SD-OCT scans of 122 eyes from 64 subjects with autosomal dominant retinitis pigmentosa were delineated by three raters using two methods, termed the profile and en face methods. For each method, we determined the measurement reliabilities for boundary area (EZ area) and boundary shape, percentage of eyes with measurable EZ (measurability), time required, and effect of rater experience. RESULTS: With expert raters, inter- and intrarater area intraclass correlation coefficients (ICCs) were 0.986 and 0.980 (profile) and 0.959 and 0.976 (en face), respectively. In comparison, the corresponding shape ICCs were 0.906 and 0.891 (profile) and 0.845 and 0.885 (en face), indicating lower reliability for the raw measurements (P ≤ 0.01). Only profile method interrater reliability depended on experience. Average measurement times per eye were 8.2 (profile) and 4.1 (en face) minutes. Measurability percentages were 99.2% (profile) and 73.0% (en face). CONCLUSIONS: The slower profile method had better measurability, and with expert raters yielded the best area and shape reliabilities. The faster, but less sensitive, en face method still showed excellent reliability, and was less dependent on experience. Shape analysis reveals the boundary measurements underpinning EZ area have lower reliability than suggested by area analysis. TRANSLATIONAL RELEVANCE: This study provides new reliability perspectives and logistical considerations for the manual measurement procedures that generate EZ area outcome measures. The Association for Research in Vision and Ophthalmology 2019-06-11 /pmc/articles/PMC6561133/ /pubmed/31211002 http://dx.doi.org/10.1167/tvst.8.3.37 Text en Copyright 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Smith, Travis B.
Parker, Maria A.
Steinkamp, Peter N.
Romo, Albert
Erker, Laura R.
Lujan, Brandon J.
Smith, Ning
Reliability of Spectral-Domain OCT Ellipsoid Zone Area and Shape Measurements in Retinitis Pigmentosa
title Reliability of Spectral-Domain OCT Ellipsoid Zone Area and Shape Measurements in Retinitis Pigmentosa
title_full Reliability of Spectral-Domain OCT Ellipsoid Zone Area and Shape Measurements in Retinitis Pigmentosa
title_fullStr Reliability of Spectral-Domain OCT Ellipsoid Zone Area and Shape Measurements in Retinitis Pigmentosa
title_full_unstemmed Reliability of Spectral-Domain OCT Ellipsoid Zone Area and Shape Measurements in Retinitis Pigmentosa
title_short Reliability of Spectral-Domain OCT Ellipsoid Zone Area and Shape Measurements in Retinitis Pigmentosa
title_sort reliability of spectral-domain oct ellipsoid zone area and shape measurements in retinitis pigmentosa
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6561133/
https://www.ncbi.nlm.nih.gov/pubmed/31211002
http://dx.doi.org/10.1167/tvst.8.3.37
work_keys_str_mv AT smithtravisb reliabilityofspectraldomainoctellipsoidzoneareaandshapemeasurementsinretinitispigmentosa
AT parkermariaa reliabilityofspectraldomainoctellipsoidzoneareaandshapemeasurementsinretinitispigmentosa
AT steinkamppetern reliabilityofspectraldomainoctellipsoidzoneareaandshapemeasurementsinretinitispigmentosa
AT romoalbert reliabilityofspectraldomainoctellipsoidzoneareaandshapemeasurementsinretinitispigmentosa
AT erkerlaurar reliabilityofspectraldomainoctellipsoidzoneareaandshapemeasurementsinretinitispigmentosa
AT lujanbrandonj reliabilityofspectraldomainoctellipsoidzoneareaandshapemeasurementsinretinitispigmentosa
AT smithning reliabilityofspectraldomainoctellipsoidzoneareaandshapemeasurementsinretinitispigmentosa