Cargando…

Biomechanical Effect of Different Graft Heights on Adjacent Segment and Graft Segment Following C4/C5 Anterior Cervical Discectomy and Fusion: A Finite Element Analysis

BACKGROUND: The finite element analysis (FEA) was used to explore the effect of different graft heights on adjacent segment and graft segment stress after C4/5 anterior cervical discectomy and fusion (ACDF). MATERIAL/METHODS: A detailed, geometrically accurate 3-dimensional cervical spine model was...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Yuhua, Zhou, Jiaming, Guo, Xing, Cai, Zongxi, Liu, Haofei, Xue, Yuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6561140/
https://www.ncbi.nlm.nih.gov/pubmed/31163019
http://dx.doi.org/10.12659/MSM.916629
_version_ 1783426091067637760
author Zhang, Yuhua
Zhou, Jiaming
Guo, Xing
Cai, Zongxi
Liu, Haofei
Xue, Yuan
author_facet Zhang, Yuhua
Zhou, Jiaming
Guo, Xing
Cai, Zongxi
Liu, Haofei
Xue, Yuan
author_sort Zhang, Yuhua
collection PubMed
description BACKGROUND: The finite element analysis (FEA) was used to explore the effect of different graft heights on adjacent segment and graft segment stress after C4/5 anterior cervical discectomy and fusion (ACDF). MATERIAL/METHODS: A detailed, geometrically accurate 3-dimensional cervical spine model was successfully built from computed tomography (CT) scanning of a healthy adult male. We changed the graft height in C4–C5 to be 90%, 150%, 175%, and 200% of the preoperative disc height and simulated the postoperative scenarios with different bone graft height, respectively. A stress analysis was conducted on the adjacent segment and graft segment. RESULTS: The maximum von Mises stress on C3–C4 showed that when the graft height was 200%, the values were 0.99 MPa, 0.85 MPa, 0.91 MPa, and 0.89 MPa in different loading conditions. For C5–C6, the maximum von Mises stress was 0.77 MPa, 0.83 MPa, 0.91 MPa, and 0.81 MPa, observed when the graft height was 175%, except in extension condition. With regard to graft segment (C4–C5), the biggest von Mises stress was 1.25 MPa, 1.77 MPa, 1.75 MPa, and 1.81 MPa observed at 200% graft height. For these 3 segments, the smallest von Mises stress was found at 150% graft height under the 4 loading conditions. CONCLUSIONS: The graft height makes an important difference on the stress on the adjacent segment and the graft segment after anterior cervical discectomy and fusion. A 150% graft height was considered the proper graft height in C4/C5 ACDF, with the lowest stress on the adjacent segment and the graft segment.
format Online
Article
Text
id pubmed-6561140
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-65611402019-06-26 Biomechanical Effect of Different Graft Heights on Adjacent Segment and Graft Segment Following C4/C5 Anterior Cervical Discectomy and Fusion: A Finite Element Analysis Zhang, Yuhua Zhou, Jiaming Guo, Xing Cai, Zongxi Liu, Haofei Xue, Yuan Med Sci Monit Clinical Research BACKGROUND: The finite element analysis (FEA) was used to explore the effect of different graft heights on adjacent segment and graft segment stress after C4/5 anterior cervical discectomy and fusion (ACDF). MATERIAL/METHODS: A detailed, geometrically accurate 3-dimensional cervical spine model was successfully built from computed tomography (CT) scanning of a healthy adult male. We changed the graft height in C4–C5 to be 90%, 150%, 175%, and 200% of the preoperative disc height and simulated the postoperative scenarios with different bone graft height, respectively. A stress analysis was conducted on the adjacent segment and graft segment. RESULTS: The maximum von Mises stress on C3–C4 showed that when the graft height was 200%, the values were 0.99 MPa, 0.85 MPa, 0.91 MPa, and 0.89 MPa in different loading conditions. For C5–C6, the maximum von Mises stress was 0.77 MPa, 0.83 MPa, 0.91 MPa, and 0.81 MPa, observed when the graft height was 175%, except in extension condition. With regard to graft segment (C4–C5), the biggest von Mises stress was 1.25 MPa, 1.77 MPa, 1.75 MPa, and 1.81 MPa observed at 200% graft height. For these 3 segments, the smallest von Mises stress was found at 150% graft height under the 4 loading conditions. CONCLUSIONS: The graft height makes an important difference on the stress on the adjacent segment and the graft segment after anterior cervical discectomy and fusion. A 150% graft height was considered the proper graft height in C4/C5 ACDF, with the lowest stress on the adjacent segment and the graft segment. International Scientific Literature, Inc. 2019-06-04 /pmc/articles/PMC6561140/ /pubmed/31163019 http://dx.doi.org/10.12659/MSM.916629 Text en © Med Sci Monit, 2019 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Zhang, Yuhua
Zhou, Jiaming
Guo, Xing
Cai, Zongxi
Liu, Haofei
Xue, Yuan
Biomechanical Effect of Different Graft Heights on Adjacent Segment and Graft Segment Following C4/C5 Anterior Cervical Discectomy and Fusion: A Finite Element Analysis
title Biomechanical Effect of Different Graft Heights on Adjacent Segment and Graft Segment Following C4/C5 Anterior Cervical Discectomy and Fusion: A Finite Element Analysis
title_full Biomechanical Effect of Different Graft Heights on Adjacent Segment and Graft Segment Following C4/C5 Anterior Cervical Discectomy and Fusion: A Finite Element Analysis
title_fullStr Biomechanical Effect of Different Graft Heights on Adjacent Segment and Graft Segment Following C4/C5 Anterior Cervical Discectomy and Fusion: A Finite Element Analysis
title_full_unstemmed Biomechanical Effect of Different Graft Heights on Adjacent Segment and Graft Segment Following C4/C5 Anterior Cervical Discectomy and Fusion: A Finite Element Analysis
title_short Biomechanical Effect of Different Graft Heights on Adjacent Segment and Graft Segment Following C4/C5 Anterior Cervical Discectomy and Fusion: A Finite Element Analysis
title_sort biomechanical effect of different graft heights on adjacent segment and graft segment following c4/c5 anterior cervical discectomy and fusion: a finite element analysis
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6561140/
https://www.ncbi.nlm.nih.gov/pubmed/31163019
http://dx.doi.org/10.12659/MSM.916629
work_keys_str_mv AT zhangyuhua biomechanicaleffectofdifferentgraftheightsonadjacentsegmentandgraftsegmentfollowingc4c5anteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT zhoujiaming biomechanicaleffectofdifferentgraftheightsonadjacentsegmentandgraftsegmentfollowingc4c5anteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT guoxing biomechanicaleffectofdifferentgraftheightsonadjacentsegmentandgraftsegmentfollowingc4c5anteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT caizongxi biomechanicaleffectofdifferentgraftheightsonadjacentsegmentandgraftsegmentfollowingc4c5anteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT liuhaofei biomechanicaleffectofdifferentgraftheightsonadjacentsegmentandgraftsegmentfollowingc4c5anteriorcervicaldiscectomyandfusionafiniteelementanalysis
AT xueyuan biomechanicaleffectofdifferentgraftheightsonadjacentsegmentandgraftsegmentfollowingc4c5anteriorcervicaldiscectomyandfusionafiniteelementanalysis