Cargando…

The Use of Percent Change in RR Interval for Data Exclusion in Analyzing 24-h Time Domain Heart Rate Variability in Rodents

While epidemiological data support the link between reduced heart rate variability (HRV) and a multitude of pathologies, the mechanisms underlying changes in HRV and disease progression are poorly understood. Even though we have numerous rodent models of disease for mechanistic studies, not being ab...

Descripción completa

Detalles Bibliográficos
Autores principales: Karey, Emma, Pan, Shiyue, Morris, Amber N., Bruun, Donald A., Lein, Pamela J., Chen, Chao-Yin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6562196/
https://www.ncbi.nlm.nih.gov/pubmed/31244671
http://dx.doi.org/10.3389/fphys.2019.00693
_version_ 1783426248422195200
author Karey, Emma
Pan, Shiyue
Morris, Amber N.
Bruun, Donald A.
Lein, Pamela J.
Chen, Chao-Yin
author_facet Karey, Emma
Pan, Shiyue
Morris, Amber N.
Bruun, Donald A.
Lein, Pamela J.
Chen, Chao-Yin
author_sort Karey, Emma
collection PubMed
description While epidemiological data support the link between reduced heart rate variability (HRV) and a multitude of pathologies, the mechanisms underlying changes in HRV and disease progression are poorly understood. Even though we have numerous rodent models of disease for mechanistic studies, not being able to reliably measure HRV in conscious, freely moving rodents has hindered our ability to extrapolate the role of HRV in the progression from normal physiology to pathology. The sheer number of heart beats per day (>800,000 in mice) makes data exclusion both time consuming and daunting. We sought to evaluate an RR interval exclusion method based on percent (%) change of adjacent RR intervals. Two approaches were evaluated: % change from “either” and “both” adjacent RR intervals. The data exclusion method based on standard deviation (SD) was also evaluated for comparison. Receiver operating characteristic (ROC) curves were generated to determine the performance of each method. Results showed that exclusion based on % change from “either” adjacent RR intervals was the most accurate method in identifying normal and abnormal RR intervals, with an overall accuracy of 0.92–0.99. As the exclusion value increased (% change or SD), the sensitivity (correctly including normal RR intervals) increased exponentially while the specificity (correctly rejecting abnormal RR intervals) decreased linearly. Compared to the SD method, the “either” approach had a steeper rise in sensitivity and a more gradual decrease in specificity. The intersection of sensitivity and specificity where the exclusion criterion had the same accuracy in identifying normal and abnormal RR intervals was 10–20% change for the “either” approach and ∼ 1 SD for the SD-based exclusion method. Graphically (tachogram and Lorenz plot), 20% change from either adjacent RR interval resembled the data after manual exclusion. Finally, overall (SDNN) and short-term (rMSSD) indices of HRV generated using 20% change from “either” adjacent RR intervals as the exclusion criterion were closer to the manual exclusion method with lower subject-to-subject variability than those generated using the 2 SD exclusion criterion. Thus, 20% change from “either” adjacent RR intervals is a good criterion for data exclusion for reliable 24-h time domain HRV analysis in rodents.
format Online
Article
Text
id pubmed-6562196
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-65621962019-06-26 The Use of Percent Change in RR Interval for Data Exclusion in Analyzing 24-h Time Domain Heart Rate Variability in Rodents Karey, Emma Pan, Shiyue Morris, Amber N. Bruun, Donald A. Lein, Pamela J. Chen, Chao-Yin Front Physiol Physiology While epidemiological data support the link between reduced heart rate variability (HRV) and a multitude of pathologies, the mechanisms underlying changes in HRV and disease progression are poorly understood. Even though we have numerous rodent models of disease for mechanistic studies, not being able to reliably measure HRV in conscious, freely moving rodents has hindered our ability to extrapolate the role of HRV in the progression from normal physiology to pathology. The sheer number of heart beats per day (>800,000 in mice) makes data exclusion both time consuming and daunting. We sought to evaluate an RR interval exclusion method based on percent (%) change of adjacent RR intervals. Two approaches were evaluated: % change from “either” and “both” adjacent RR intervals. The data exclusion method based on standard deviation (SD) was also evaluated for comparison. Receiver operating characteristic (ROC) curves were generated to determine the performance of each method. Results showed that exclusion based on % change from “either” adjacent RR intervals was the most accurate method in identifying normal and abnormal RR intervals, with an overall accuracy of 0.92–0.99. As the exclusion value increased (% change or SD), the sensitivity (correctly including normal RR intervals) increased exponentially while the specificity (correctly rejecting abnormal RR intervals) decreased linearly. Compared to the SD method, the “either” approach had a steeper rise in sensitivity and a more gradual decrease in specificity. The intersection of sensitivity and specificity where the exclusion criterion had the same accuracy in identifying normal and abnormal RR intervals was 10–20% change for the “either” approach and ∼ 1 SD for the SD-based exclusion method. Graphically (tachogram and Lorenz plot), 20% change from either adjacent RR interval resembled the data after manual exclusion. Finally, overall (SDNN) and short-term (rMSSD) indices of HRV generated using 20% change from “either” adjacent RR intervals as the exclusion criterion were closer to the manual exclusion method with lower subject-to-subject variability than those generated using the 2 SD exclusion criterion. Thus, 20% change from “either” adjacent RR intervals is a good criterion for data exclusion for reliable 24-h time domain HRV analysis in rodents. Frontiers Media S.A. 2019-06-06 /pmc/articles/PMC6562196/ /pubmed/31244671 http://dx.doi.org/10.3389/fphys.2019.00693 Text en Copyright © 2019 Karey, Pan, Morris, Bruun, Lein and Chen. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Karey, Emma
Pan, Shiyue
Morris, Amber N.
Bruun, Donald A.
Lein, Pamela J.
Chen, Chao-Yin
The Use of Percent Change in RR Interval for Data Exclusion in Analyzing 24-h Time Domain Heart Rate Variability in Rodents
title The Use of Percent Change in RR Interval for Data Exclusion in Analyzing 24-h Time Domain Heart Rate Variability in Rodents
title_full The Use of Percent Change in RR Interval for Data Exclusion in Analyzing 24-h Time Domain Heart Rate Variability in Rodents
title_fullStr The Use of Percent Change in RR Interval for Data Exclusion in Analyzing 24-h Time Domain Heart Rate Variability in Rodents
title_full_unstemmed The Use of Percent Change in RR Interval for Data Exclusion in Analyzing 24-h Time Domain Heart Rate Variability in Rodents
title_short The Use of Percent Change in RR Interval for Data Exclusion in Analyzing 24-h Time Domain Heart Rate Variability in Rodents
title_sort use of percent change in rr interval for data exclusion in analyzing 24-h time domain heart rate variability in rodents
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6562196/
https://www.ncbi.nlm.nih.gov/pubmed/31244671
http://dx.doi.org/10.3389/fphys.2019.00693
work_keys_str_mv AT kareyemma theuseofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT panshiyue theuseofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT morrisambern theuseofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT bruundonalda theuseofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT leinpamelaj theuseofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT chenchaoyin theuseofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT kareyemma useofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT panshiyue useofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT morrisambern useofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT bruundonalda useofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT leinpamelaj useofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents
AT chenchaoyin useofpercentchangeinrrintervalfordataexclusioninanalyzing24htimedomainheartratevariabilityinrodents