Cargando…

A Measurement-Data-Driven Control Approach towards Variance Reduction of Micromachined Resonant Accelerometer under Multi Unknown Disturbances

This paper first presents an adaptive expectation-maximization (AEM) control algorithm based on a measurement-data-driven model to reduce the variance of microelectromechanical system (MEMS) accelerometer sensor under multi disturbances. Significantly different characteristics of the disturbances, c...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Qiang, Yang, Dengfeng, Zhou, Jie, Wu, Yixuan, Zhang, Yinan, Yuan, Weizheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6562456/
https://www.ncbi.nlm.nih.gov/pubmed/31052222
http://dx.doi.org/10.3390/mi10050294
_version_ 1783426304493748224
author Shen, Qiang
Yang, Dengfeng
Zhou, Jie
Wu, Yixuan
Zhang, Yinan
Yuan, Weizheng
author_facet Shen, Qiang
Yang, Dengfeng
Zhou, Jie
Wu, Yixuan
Zhang, Yinan
Yuan, Weizheng
author_sort Shen, Qiang
collection PubMed
description This paper first presents an adaptive expectation-maximization (AEM) control algorithm based on a measurement-data-driven model to reduce the variance of microelectromechanical system (MEMS) accelerometer sensor under multi disturbances. Significantly different characteristics of the disturbances, consisting of drastic-magnitude, short-duration vibration in the external environment, and slowly-varying, long-duration fluctuation inside the sensor are first constructed together with the measurement model of the accelerometer. Next, through establishing a data-driven model based on a historical small measurement sample, the window length of filter of the presented algorithm is adaptively chosen to estimate the sensor state and identify these disturbances simultaneously. Simulation results of the proposed AEM algorithm based on experimental test are compared with the Kalman filter (KF), least mean square (LMS), and regular EM (REM) methods. Variances of the estimated equivalent input under static condition are 0.212 mV, 0.149 mV, 0.015 mV, and 0.004 mV by the KF, LMS, REM, and AEM, respectively. Under dynamic conditions, the corresponding variances are 35.5 mV, 2.07 mV, 2.0 mV, and 1.45 mV, respectively. The variances under static condition based on the proposed method are reduced to 1.9%, 2.8%, and 27.3%, compared with the KF, LMS, and REM methods, respectively. The corresponding variances under dynamic condition are reduced to 4.1%, 70.1%, and 72.5%, respectively. The effectiveness of the proposed method is verified to reduce the variance of the MEMS resonant accelerometer sensor.
format Online
Article
Text
id pubmed-6562456
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65624562019-06-17 A Measurement-Data-Driven Control Approach towards Variance Reduction of Micromachined Resonant Accelerometer under Multi Unknown Disturbances Shen, Qiang Yang, Dengfeng Zhou, Jie Wu, Yixuan Zhang, Yinan Yuan, Weizheng Micromachines (Basel) Article This paper first presents an adaptive expectation-maximization (AEM) control algorithm based on a measurement-data-driven model to reduce the variance of microelectromechanical system (MEMS) accelerometer sensor under multi disturbances. Significantly different characteristics of the disturbances, consisting of drastic-magnitude, short-duration vibration in the external environment, and slowly-varying, long-duration fluctuation inside the sensor are first constructed together with the measurement model of the accelerometer. Next, through establishing a data-driven model based on a historical small measurement sample, the window length of filter of the presented algorithm is adaptively chosen to estimate the sensor state and identify these disturbances simultaneously. Simulation results of the proposed AEM algorithm based on experimental test are compared with the Kalman filter (KF), least mean square (LMS), and regular EM (REM) methods. Variances of the estimated equivalent input under static condition are 0.212 mV, 0.149 mV, 0.015 mV, and 0.004 mV by the KF, LMS, REM, and AEM, respectively. Under dynamic conditions, the corresponding variances are 35.5 mV, 2.07 mV, 2.0 mV, and 1.45 mV, respectively. The variances under static condition based on the proposed method are reduced to 1.9%, 2.8%, and 27.3%, compared with the KF, LMS, and REM methods, respectively. The corresponding variances under dynamic condition are reduced to 4.1%, 70.1%, and 72.5%, respectively. The effectiveness of the proposed method is verified to reduce the variance of the MEMS resonant accelerometer sensor. MDPI 2019-04-30 /pmc/articles/PMC6562456/ /pubmed/31052222 http://dx.doi.org/10.3390/mi10050294 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shen, Qiang
Yang, Dengfeng
Zhou, Jie
Wu, Yixuan
Zhang, Yinan
Yuan, Weizheng
A Measurement-Data-Driven Control Approach towards Variance Reduction of Micromachined Resonant Accelerometer under Multi Unknown Disturbances
title A Measurement-Data-Driven Control Approach towards Variance Reduction of Micromachined Resonant Accelerometer under Multi Unknown Disturbances
title_full A Measurement-Data-Driven Control Approach towards Variance Reduction of Micromachined Resonant Accelerometer under Multi Unknown Disturbances
title_fullStr A Measurement-Data-Driven Control Approach towards Variance Reduction of Micromachined Resonant Accelerometer under Multi Unknown Disturbances
title_full_unstemmed A Measurement-Data-Driven Control Approach towards Variance Reduction of Micromachined Resonant Accelerometer under Multi Unknown Disturbances
title_short A Measurement-Data-Driven Control Approach towards Variance Reduction of Micromachined Resonant Accelerometer under Multi Unknown Disturbances
title_sort measurement-data-driven control approach towards variance reduction of micromachined resonant accelerometer under multi unknown disturbances
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6562456/
https://www.ncbi.nlm.nih.gov/pubmed/31052222
http://dx.doi.org/10.3390/mi10050294
work_keys_str_mv AT shenqiang ameasurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT yangdengfeng ameasurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT zhoujie ameasurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT wuyixuan ameasurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT zhangyinan ameasurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT yuanweizheng ameasurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT shenqiang measurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT yangdengfeng measurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT zhoujie measurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT wuyixuan measurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT zhangyinan measurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances
AT yuanweizheng measurementdatadrivencontrolapproachtowardsvariancereductionofmicromachinedresonantaccelerometerundermultiunknowndisturbances