Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis

OBJECTIVE: To investigate the potency of a hand-held point-of-care electronic-nose to diagnose pulmonary tuberculosis (PTB) among those suspected of PTB. METHODS: Setting: Lung clinics and Dr. Sardjito Hospital, Yogyakarta, Indonesia. Participants: patients with suspected PTB and healthy controls. S...

Descripción completa

Detalles Bibliográficos
Autores principales: Saktiawati, Antonia M. I., Stienstra, Ymkje, Subronto, Yanri W., Rintiswati, Ning, Sumardi, Gerritsen, Jan-Willem, Oord, Henny, Akkerman, Onno W., van der Werf, Tjip S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6563983/
https://www.ncbi.nlm.nih.gov/pubmed/31194793
http://dx.doi.org/10.1371/journal.pone.0217963
_version_ 1783426631521533952
author Saktiawati, Antonia M. I.
Stienstra, Ymkje
Subronto, Yanri W.
Rintiswati, Ning
Sumardi,
Gerritsen, Jan-Willem
Oord, Henny
Akkerman, Onno W.
van der Werf, Tjip S.
author_facet Saktiawati, Antonia M. I.
Stienstra, Ymkje
Subronto, Yanri W.
Rintiswati, Ning
Sumardi,
Gerritsen, Jan-Willem
Oord, Henny
Akkerman, Onno W.
van der Werf, Tjip S.
author_sort Saktiawati, Antonia M. I.
collection PubMed
description OBJECTIVE: To investigate the potency of a hand-held point-of-care electronic-nose to diagnose pulmonary tuberculosis (PTB) among those suspected of PTB. METHODS: Setting: Lung clinics and Dr. Sardjito Hospital, Yogyakarta, Indonesia. Participants: patients with suspected PTB and healthy controls. Sampling: 5 minutes exhaled breath. Sputum-smear-microscopy, culture, chest-radiography, and follow-up for 1.5–2.5 years, were used to classify patients with suspected PTB as active PTB, probably active PTB, probably no PTB, and no PTB. After building a breath model based on active PTB, no PTB, and healthy controls (Calibration phase), we validated the model in all patients with suspected PTB (Validation phase). In each variable (sex, age, Body Mass Index, co-morbidities, smoking status, consumption of alcohol, use of antibiotics, flu symptoms, stress, food and drink intake), one stratum’s Receiver Operating Characteristic (ROC)-curve indicating sensitivity and specificity of the breath test was compared with another stratum’s ROC-curve. Differences between Area-under-the-Curve between strata (p<0.05) indicated an association between the variable and sensitivity—specificity of the breath test. Statistical analysis was performed using STATA/SE 15. RESULTS: Of 400 enrolled participants, 73 were excluded due to extra-pulmonary TB, incomplete data, previous TB, and cancer. Calibration phase involved 182 subjects, and the result was validated in 287 subjects. Sensitivity was 85% (95%CI: 75–92%) and 78% (95%CI: 70–85%), specificity was 55% (95%CI: 44–65%) and 42% (95%CI: 34–50%), in calibration and validation phases, respectively. Test sensitivity and specificity were lower in men. CONCLUSION: The electronic-nose showed modest sensitivity and low specificity among patients with suspected PTB. To improve the sensitivity, a larger calibration group needs to be involved. With its portable form, it could be used for TB screening in remote rural areas and health care settings.
format Online
Article
Text
id pubmed-6563983
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-65639832019-06-20 Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis Saktiawati, Antonia M. I. Stienstra, Ymkje Subronto, Yanri W. Rintiswati, Ning Sumardi, Gerritsen, Jan-Willem Oord, Henny Akkerman, Onno W. van der Werf, Tjip S. PLoS One Research Article OBJECTIVE: To investigate the potency of a hand-held point-of-care electronic-nose to diagnose pulmonary tuberculosis (PTB) among those suspected of PTB. METHODS: Setting: Lung clinics and Dr. Sardjito Hospital, Yogyakarta, Indonesia. Participants: patients with suspected PTB and healthy controls. Sampling: 5 minutes exhaled breath. Sputum-smear-microscopy, culture, chest-radiography, and follow-up for 1.5–2.5 years, were used to classify patients with suspected PTB as active PTB, probably active PTB, probably no PTB, and no PTB. After building a breath model based on active PTB, no PTB, and healthy controls (Calibration phase), we validated the model in all patients with suspected PTB (Validation phase). In each variable (sex, age, Body Mass Index, co-morbidities, smoking status, consumption of alcohol, use of antibiotics, flu symptoms, stress, food and drink intake), one stratum’s Receiver Operating Characteristic (ROC)-curve indicating sensitivity and specificity of the breath test was compared with another stratum’s ROC-curve. Differences between Area-under-the-Curve between strata (p<0.05) indicated an association between the variable and sensitivity—specificity of the breath test. Statistical analysis was performed using STATA/SE 15. RESULTS: Of 400 enrolled participants, 73 were excluded due to extra-pulmonary TB, incomplete data, previous TB, and cancer. Calibration phase involved 182 subjects, and the result was validated in 287 subjects. Sensitivity was 85% (95%CI: 75–92%) and 78% (95%CI: 70–85%), specificity was 55% (95%CI: 44–65%) and 42% (95%CI: 34–50%), in calibration and validation phases, respectively. Test sensitivity and specificity were lower in men. CONCLUSION: The electronic-nose showed modest sensitivity and low specificity among patients with suspected PTB. To improve the sensitivity, a larger calibration group needs to be involved. With its portable form, it could be used for TB screening in remote rural areas and health care settings. Public Library of Science 2019-06-13 /pmc/articles/PMC6563983/ /pubmed/31194793 http://dx.doi.org/10.1371/journal.pone.0217963 Text en © 2019 Saktiawati et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Saktiawati, Antonia M. I.
Stienstra, Ymkje
Subronto, Yanri W.
Rintiswati, Ning
Sumardi,
Gerritsen, Jan-Willem
Oord, Henny
Akkerman, Onno W.
van der Werf, Tjip S.
Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis
title Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis
title_full Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis
title_fullStr Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis
title_full_unstemmed Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis
title_short Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis
title_sort sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6563983/
https://www.ncbi.nlm.nih.gov/pubmed/31194793
http://dx.doi.org/10.1371/journal.pone.0217963
work_keys_str_mv AT saktiawatiantoniami sensitivityandspecificityofanelectronicnoseindiagnosingpulmonarytuberculosisamongpatientswithsuspectedtuberculosis
AT stienstraymkje sensitivityandspecificityofanelectronicnoseindiagnosingpulmonarytuberculosisamongpatientswithsuspectedtuberculosis
AT subrontoyanriw sensitivityandspecificityofanelectronicnoseindiagnosingpulmonarytuberculosisamongpatientswithsuspectedtuberculosis
AT rintiswatining sensitivityandspecificityofanelectronicnoseindiagnosingpulmonarytuberculosisamongpatientswithsuspectedtuberculosis
AT sumardi sensitivityandspecificityofanelectronicnoseindiagnosingpulmonarytuberculosisamongpatientswithsuspectedtuberculosis
AT gerritsenjanwillem sensitivityandspecificityofanelectronicnoseindiagnosingpulmonarytuberculosisamongpatientswithsuspectedtuberculosis
AT oordhenny sensitivityandspecificityofanelectronicnoseindiagnosingpulmonarytuberculosisamongpatientswithsuspectedtuberculosis
AT akkermanonnow sensitivityandspecificityofanelectronicnoseindiagnosingpulmonarytuberculosisamongpatientswithsuspectedtuberculosis
AT vanderwerftjips sensitivityandspecificityofanelectronicnoseindiagnosingpulmonarytuberculosisamongpatientswithsuspectedtuberculosis