Cargando…
Clinical evaluation of left ventricular function and morphology using an accelerated k-t sensitivity encoding method in cardiovascular magnetic resonance
OBJECTIVES: To provide clinical validation of a recent 2D SENSE-based accelerated cardiovascular magnetic resonance (CMR) sequence (accelerated k-t SENSE), investigating whether this technique accurately quantifies left ventricle (LV) volumes, function, and mass as compared to 2D cine steady-state f...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6565778/ https://www.ncbi.nlm.nih.gov/pubmed/31197500 http://dx.doi.org/10.1186/s13244-019-0750-6 |
Sumario: | OBJECTIVES: To provide clinical validation of a recent 2D SENSE-based accelerated cardiovascular magnetic resonance (CMR) sequence (accelerated k-t SENSE), investigating whether this technique accurately quantifies left ventricle (LV) volumes, function, and mass as compared to 2D cine steady-state free precession (2D-SSFP). METHODS: Healthy volunteers (n = 16) and consecutive heart failure patients (n = 26) were scanned using a 1.5 T MRI system. Two LV short axis (SA) stacks were acquired: (1) accelerated k-t SENSE (5–6 breath-holds; temporal/spatial resolution: 37 ms/1.82 × 1.87 mm; acceleration factor = 4) and (2) standard 2D-SSFP (10–12 breath-holds; temporal/spatial resolution: 49 ms/1.67 × 1.87 mm, parallel imaging). Ascending aorta phase-contrast was performed on all volunteers as a reference to compare LV stroke volumes (LVSV) and validate the sequences. An image quality score for SA images was used, with lower scores indicating better quality (from 0 to 18). RESULTS: There was a high agreement between accelerated k-t SENSE and 2D-SSFP for LV measurements: bias (limits of agreement) of 2.4% (− 5.4% to 10.1%), 6.9 mL/m(2) (− 4.7 to 18.6 mL/m(2)), − 1.5 (− 8.3 to 5.2 mL/m(2)), and − 0.2 g/m(2) (− 11.9 to 12.3 g/m(2)) for LV ejection fraction, end-diastolic volume index, end-systolic volume index, and mass index, respectively. LVSV by accelerated k-t SENSE presented good agreement with aortic flow. Interobserver and intraobserver variabilities for all LV parameters were also high. CONCLUSION: The accelerated k-t SENSE CMR sequence is clinically feasible and accurately quantifies LV volumes, function, and mass, with short acquisition time and good image quality. |
---|