Cargando…

Manufacturing a Micro-model with Integrated Fibre Optic Pressure Sensors

The measurement of fluid pressure inside pores is a major challenge in experimental studies of two-phase flow in porous media. In this paper, we describe the manufacturing procedure of a micro-model with integrated fibre optic pressure sensors. They have a circular measurement window with a diameter...

Descripción completa

Detalles Bibliográficos
Autores principales: Zarikos, I. M., Hassanizadeh, S. M., van Oosterhout, L. M., van Oordt, W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6566213/
https://www.ncbi.nlm.nih.gov/pubmed/31258227
http://dx.doi.org/10.1007/s11242-018-1000-y
_version_ 1783426801713807360
author Zarikos, I. M.
Hassanizadeh, S. M.
van Oosterhout, L. M.
van Oordt, W.
author_facet Zarikos, I. M.
Hassanizadeh, S. M.
van Oosterhout, L. M.
van Oordt, W.
author_sort Zarikos, I. M.
collection PubMed
description The measurement of fluid pressure inside pores is a major challenge in experimental studies of two-phase flow in porous media. In this paper, we describe the manufacturing procedure of a micro-model with integrated fibre optic pressure sensors. They have a circular measurement window with a diameter of 260 [Formula: see text] , which enables the measurement of pressure at the pore scale. As a porous medium, we used a PDMS micro-model with known physical and surface properties. A given pore geometry was produced following a procedure we had developed earlier. We explain the technology behind fibre optic pressure sensors and the procedure for integrating these sensors into a micro-model and demonstrate their utility for the measurement of pore pressure under transient two-phase flow conditions. Finally, we present and analyse results of single and two-phase flow experiments performed in the micro-model and discuss the link between small-scale fast pressure changes with pore-scale events.
format Online
Article
Text
id pubmed-6566213
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-65662132019-06-28 Manufacturing a Micro-model with Integrated Fibre Optic Pressure Sensors Zarikos, I. M. Hassanizadeh, S. M. van Oosterhout, L. M. van Oordt, W. Transp Porous Media Article The measurement of fluid pressure inside pores is a major challenge in experimental studies of two-phase flow in porous media. In this paper, we describe the manufacturing procedure of a micro-model with integrated fibre optic pressure sensors. They have a circular measurement window with a diameter of 260 [Formula: see text] , which enables the measurement of pressure at the pore scale. As a porous medium, we used a PDMS micro-model with known physical and surface properties. A given pore geometry was produced following a procedure we had developed earlier. We explain the technology behind fibre optic pressure sensors and the procedure for integrating these sensors into a micro-model and demonstrate their utility for the measurement of pore pressure under transient two-phase flow conditions. Finally, we present and analyse results of single and two-phase flow experiments performed in the micro-model and discuss the link between small-scale fast pressure changes with pore-scale events. Springer Netherlands 2018-01-11 2018 /pmc/articles/PMC6566213/ /pubmed/31258227 http://dx.doi.org/10.1007/s11242-018-1000-y Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Zarikos, I. M.
Hassanizadeh, S. M.
van Oosterhout, L. M.
van Oordt, W.
Manufacturing a Micro-model with Integrated Fibre Optic Pressure Sensors
title Manufacturing a Micro-model with Integrated Fibre Optic Pressure Sensors
title_full Manufacturing a Micro-model with Integrated Fibre Optic Pressure Sensors
title_fullStr Manufacturing a Micro-model with Integrated Fibre Optic Pressure Sensors
title_full_unstemmed Manufacturing a Micro-model with Integrated Fibre Optic Pressure Sensors
title_short Manufacturing a Micro-model with Integrated Fibre Optic Pressure Sensors
title_sort manufacturing a micro-model with integrated fibre optic pressure sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6566213/
https://www.ncbi.nlm.nih.gov/pubmed/31258227
http://dx.doi.org/10.1007/s11242-018-1000-y
work_keys_str_mv AT zarikosim manufacturingamicromodelwithintegratedfibreopticpressuresensors
AT hassanizadehsm manufacturingamicromodelwithintegratedfibreopticpressuresensors
AT vanoosterhoutlm manufacturingamicromodelwithintegratedfibreopticpressuresensors
AT vanoordtw manufacturingamicromodelwithintegratedfibreopticpressuresensors