Sugar Concentration Measurement System Using Radiofrequency Sensor

A sugar solution measurement system was developed based on the dielectric properties of the sucrose molecule. An ac conductivity and tan δ study as a function of the frequency was performed to find the suitable frequency range for the measuring system. The results indicate that it is possible to obt...

Descripción completa

Detalles Bibliográficos
Autores principales: Aguila Rodriguez, Gerardo, Arias Duque, Nayda Patricia, Gonzalez Sanchez, Blanca Estela, Sandoval Gonzalez, Oscar Osvaldo, Giraldo Osorio, Oscar Hernan, Trujillo Romero, Citlalli Jessica, Wilches Torres, Miriam Andrea, Flores Cuautle, Jose de Jesus Agustin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6566320/
https://www.ncbi.nlm.nih.gov/pubmed/31121884
http://dx.doi.org/10.3390/s19102354
_version_ 1783426827107172352
author Aguila Rodriguez, Gerardo
Arias Duque, Nayda Patricia
Gonzalez Sanchez, Blanca Estela
Sandoval Gonzalez, Oscar Osvaldo
Giraldo Osorio, Oscar Hernan
Trujillo Romero, Citlalli Jessica
Wilches Torres, Miriam Andrea
Flores Cuautle, Jose de Jesus Agustin
author_facet Aguila Rodriguez, Gerardo
Arias Duque, Nayda Patricia
Gonzalez Sanchez, Blanca Estela
Sandoval Gonzalez, Oscar Osvaldo
Giraldo Osorio, Oscar Hernan
Trujillo Romero, Citlalli Jessica
Wilches Torres, Miriam Andrea
Flores Cuautle, Jose de Jesus Agustin
author_sort Aguila Rodriguez, Gerardo
collection PubMed
description A sugar solution measurement system was developed based on the dielectric properties of the sucrose molecule. An ac conductivity and tan δ study as a function of the frequency was performed to find the suitable frequency range for the measuring system. The results indicate that it is possible to obtain a better response of the sensor using the frequencies as the maxima peak in tan δ appears. Developed setup for sucrose solution was appropriate to measure in a 0.15 to 1 g/mL range with an experimental error of about 3%. The proposed system improves the measurement time over some other methods.
format Online
Article
Text
id pubmed-6566320
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65663202019-06-17 Sugar Concentration Measurement System Using Radiofrequency Sensor Aguila Rodriguez, Gerardo Arias Duque, Nayda Patricia Gonzalez Sanchez, Blanca Estela Sandoval Gonzalez, Oscar Osvaldo Giraldo Osorio, Oscar Hernan Trujillo Romero, Citlalli Jessica Wilches Torres, Miriam Andrea Flores Cuautle, Jose de Jesus Agustin Sensors (Basel) Article A sugar solution measurement system was developed based on the dielectric properties of the sucrose molecule. An ac conductivity and tan δ study as a function of the frequency was performed to find the suitable frequency range for the measuring system. The results indicate that it is possible to obtain a better response of the sensor using the frequencies as the maxima peak in tan δ appears. Developed setup for sucrose solution was appropriate to measure in a 0.15 to 1 g/mL range with an experimental error of about 3%. The proposed system improves the measurement time over some other methods. MDPI 2019-05-22 /pmc/articles/PMC6566320/ /pubmed/31121884 http://dx.doi.org/10.3390/s19102354 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Aguila Rodriguez, Gerardo
Arias Duque, Nayda Patricia
Gonzalez Sanchez, Blanca Estela
Sandoval Gonzalez, Oscar Osvaldo
Giraldo Osorio, Oscar Hernan
Trujillo Romero, Citlalli Jessica
Wilches Torres, Miriam Andrea
Flores Cuautle, Jose de Jesus Agustin
Sugar Concentration Measurement System Using Radiofrequency Sensor
title Sugar Concentration Measurement System Using Radiofrequency Sensor
title_full Sugar Concentration Measurement System Using Radiofrequency Sensor
title_fullStr Sugar Concentration Measurement System Using Radiofrequency Sensor
title_full_unstemmed Sugar Concentration Measurement System Using Radiofrequency Sensor
title_short Sugar Concentration Measurement System Using Radiofrequency Sensor
title_sort sugar concentration measurement system using radiofrequency sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6566320/
https://www.ncbi.nlm.nih.gov/pubmed/31121884
http://dx.doi.org/10.3390/s19102354
work_keys_str_mv AT aguilarodriguezgerardo sugarconcentrationmeasurementsystemusingradiofrequencysensor
AT ariasduquenaydapatricia sugarconcentrationmeasurementsystemusingradiofrequencysensor
AT gonzalezsanchezblancaestela sugarconcentrationmeasurementsystemusingradiofrequencysensor
AT sandovalgonzalezoscarosvaldo sugarconcentrationmeasurementsystemusingradiofrequencysensor
AT giraldoosoriooscarhernan sugarconcentrationmeasurementsystemusingradiofrequencysensor
AT trujilloromerocitlallijessica sugarconcentrationmeasurementsystemusingradiofrequencysensor
AT wilchestorresmiriamandrea sugarconcentrationmeasurementsystemusingradiofrequencysensor
AT florescuautlejosedejesusagustin sugarconcentrationmeasurementsystemusingradiofrequencysensor