Cargando…

Reducing the rare event: lessons from the implementation of a ventilator bundle

The ventilator-associated event (VAE) is a potentially avoidable complication of mechanical ventilation (MV) associated with poor outcomes. Although rare, VAEs and other nosocomial events are frequently targeted for quality improvement efforts consistent with the creed to ‘do no harm’. In October 20...

Descripción completa

Detalles Bibliográficos
Autores principales: Chumpia, Maryanne Matinee, Ganz, David A, Chang, Evelyn T, de Peralta, Shelly S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6568166/
https://www.ncbi.nlm.nih.gov/pubmed/31259278
http://dx.doi.org/10.1136/bmjoq-2018-000426
_version_ 1783427208666152960
author Chumpia, Maryanne Matinee
Ganz, David A
Chang, Evelyn T
de Peralta, Shelly S
author_facet Chumpia, Maryanne Matinee
Ganz, David A
Chang, Evelyn T
de Peralta, Shelly S
author_sort Chumpia, Maryanne Matinee
collection PubMed
description The ventilator-associated event (VAE) is a potentially avoidable complication of mechanical ventilation (MV) associated with poor outcomes. Although rare, VAEs and other nosocomial events are frequently targeted for quality improvement efforts consistent with the creed to ‘do no harm’. In October 2016, VA Greater Los Angeles (GLA) was in the lowest-performing decile of VA medical centres on a composite measure of quality, owing to GLA’s relatively high VAE rate. To decrease VAEs, we sought to reduce average MV duration of patients with acute respiratory failure to less than 3 days by 1 July 2017. In our first intervention (period 1), intensive care unit (ICU) attending physicians trained residents to use an existing ventilator bundle order set; in our second intervention (period 2), we updated the order set to streamline order entry and incorporate new nurse-driven and respiratory therapist (RT)-driven spontaneous awakening trial (SAT) and spontaneous breathing trial (SBT) protocols. In period 1, the proportion of eligible patients with SAT and SBT orders increased from 29.9% and 51.2% to 67.4% and 72.6%, respectively, with sustained improvements through December 2017. Mean MV duration decreased from 7.2 days at baseline to 5.5 days in period 1 and 4.7 days in period 2; statistical process control charts revealed no significant differences, but the difference between baseline and period 2 MV duration was statistically significant at p=0.049. Bedside audits showed RTs consistently performed indicated SBTs, but there were missed opportunities for SATs due to ICU staff concerns about the SAT protocol. The rarity of VAEs, small population of ventilated patients and infrequent use of sedative infusions at GLA may have decreased the opportunity to achieve staff acceptance and use of the SAT protocol. Quality improvement teams should consider frequency of targeted outcomes when planning interventions; rare events pose challenges in implementation and evaluation of change.
format Online
Article
Text
id pubmed-6568166
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-65681662019-06-28 Reducing the rare event: lessons from the implementation of a ventilator bundle Chumpia, Maryanne Matinee Ganz, David A Chang, Evelyn T de Peralta, Shelly S BMJ Open Qual BMJ Quality Improvement report The ventilator-associated event (VAE) is a potentially avoidable complication of mechanical ventilation (MV) associated with poor outcomes. Although rare, VAEs and other nosocomial events are frequently targeted for quality improvement efforts consistent with the creed to ‘do no harm’. In October 2016, VA Greater Los Angeles (GLA) was in the lowest-performing decile of VA medical centres on a composite measure of quality, owing to GLA’s relatively high VAE rate. To decrease VAEs, we sought to reduce average MV duration of patients with acute respiratory failure to less than 3 days by 1 July 2017. In our first intervention (period 1), intensive care unit (ICU) attending physicians trained residents to use an existing ventilator bundle order set; in our second intervention (period 2), we updated the order set to streamline order entry and incorporate new nurse-driven and respiratory therapist (RT)-driven spontaneous awakening trial (SAT) and spontaneous breathing trial (SBT) protocols. In period 1, the proportion of eligible patients with SAT and SBT orders increased from 29.9% and 51.2% to 67.4% and 72.6%, respectively, with sustained improvements through December 2017. Mean MV duration decreased from 7.2 days at baseline to 5.5 days in period 1 and 4.7 days in period 2; statistical process control charts revealed no significant differences, but the difference between baseline and period 2 MV duration was statistically significant at p=0.049. Bedside audits showed RTs consistently performed indicated SBTs, but there were missed opportunities for SATs due to ICU staff concerns about the SAT protocol. The rarity of VAEs, small population of ventilated patients and infrequent use of sedative infusions at GLA may have decreased the opportunity to achieve staff acceptance and use of the SAT protocol. Quality improvement teams should consider frequency of targeted outcomes when planning interventions; rare events pose challenges in implementation and evaluation of change. BMJ Publishing Group 2019-06-12 /pmc/articles/PMC6568166/ /pubmed/31259278 http://dx.doi.org/10.1136/bmjoq-2018-000426 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle BMJ Quality Improvement report
Chumpia, Maryanne Matinee
Ganz, David A
Chang, Evelyn T
de Peralta, Shelly S
Reducing the rare event: lessons from the implementation of a ventilator bundle
title Reducing the rare event: lessons from the implementation of a ventilator bundle
title_full Reducing the rare event: lessons from the implementation of a ventilator bundle
title_fullStr Reducing the rare event: lessons from the implementation of a ventilator bundle
title_full_unstemmed Reducing the rare event: lessons from the implementation of a ventilator bundle
title_short Reducing the rare event: lessons from the implementation of a ventilator bundle
title_sort reducing the rare event: lessons from the implementation of a ventilator bundle
topic BMJ Quality Improvement report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6568166/
https://www.ncbi.nlm.nih.gov/pubmed/31259278
http://dx.doi.org/10.1136/bmjoq-2018-000426
work_keys_str_mv AT chumpiamaryannematinee reducingtherareeventlessonsfromtheimplementationofaventilatorbundle
AT ganzdavida reducingtherareeventlessonsfromtheimplementationofaventilatorbundle
AT changevelynt reducingtherareeventlessonsfromtheimplementationofaventilatorbundle
AT deperaltashellys reducingtherareeventlessonsfromtheimplementationofaventilatorbundle