Cargando…
Atrial fibrillation ablation with a spring sensor-irrigated contact force-sensing catheter compared with other ablation catheters: systematic literature review and meta-analysis
OBJECTIVES: The objective of our review was to systematically assess available evidence on the effectiveness, safety and efficiency of a spring sensor-irrigated contact force (CF) catheter (THERMOCOOL SMARTTOUCH Catheter (ST)) for percutaneous ablation of paroxysmal or persistent atrial fibrillation...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6575819/ https://www.ncbi.nlm.nih.gov/pubmed/31189669 http://dx.doi.org/10.1136/bmjopen-2018-023775 |
Sumario: | OBJECTIVES: The objective of our review was to systematically assess available evidence on the effectiveness, safety and efficiency of a spring sensor-irrigated contact force (CF) catheter (THERMOCOOL SMARTTOUCH Catheter (ST)) for percutaneous ablation of paroxysmal or persistent atrial fibrillation (AF), compared with other ablation catheters, or with the ST with the operator blinded to CF data. DESIGN: Systematic literature review and meta-analysis. BACKGROUND: Emerging evidence suggests improved clinical outcomes of AF ablation using CF-sensing catheters; however, reviews to date have included data from multiple, distinct CF technologies. METHODS: We conducted a systematic review and meta-analysis of published studies comparing the use of ST versus other ablation catheters for the treatment of AF. A comprehensive search of electronic and manual sources was conducted. The primary endpoint was freedom from recurrent atrial tachyarrhythmia (AT) at 12 months. Procedural and safety data were also analysed. RESULTS: Thirty-four studies enrolling 5004 patients were eligible. The use of ST was associated with increased odds of freedom from AT at 12 months (71.0%vs60.8%; OR 1.454, 95% CI 1.12 to 1.88, p=0.004) over the comparator group, and the effect size was most evident in paroxysmal AF patients (75.6%vs64.7%; OR 1.560, 95% CI 1.09 to 2.24, p=0.015). Procedure and fluoroscopy times were shorter with ST (p=0.05 and p<0.01, respectively, vs comparator groups). The reduction in procedure time is estimated at 15.5 min (9.0%), and fluoroscopy time 4.8 min (18.7%). Complication rates, including cardiac tamponade, did not differ between groups. CONCLUSIONS: Compared with the use of other catheters, AF ablation using the CF-sensing ST catheter for AF is associated with improved success rates, shorter procedure and fluoroscopy times and similar safety profile. |
---|