Cargando…

High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo

PURPOSE: Isotropic high-resolution three-dimensional (3D) magnetic resonance neurography (MRN) is increasingly used to depict even small and highly oblique nerves of the lumbosacral plexus (LSP). The present study introduces a T2 mapping sequence (T2-prepared 3D turbo spin echo) that is B1-insensiti...

Descripción completa

Detalles Bibliográficos
Autores principales: Sollmann, Nico, Weidlich, Dominik, Cervantes, Barbara, Klupp, Elisabeth, Ganter, Carl, Kooijman, Hendrik, Rummeny, Ernst J., Zimmer, Claus, Kirschke, Jan S., Karampinos, Dimitrios C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6579865/
https://www.ncbi.nlm.nih.gov/pubmed/29322233
http://dx.doi.org/10.1007/s00062-017-0658-9
_version_ 1783427920095608832
author Sollmann, Nico
Weidlich, Dominik
Cervantes, Barbara
Klupp, Elisabeth
Ganter, Carl
Kooijman, Hendrik
Rummeny, Ernst J.
Zimmer, Claus
Kirschke, Jan S.
Karampinos, Dimitrios C.
author_facet Sollmann, Nico
Weidlich, Dominik
Cervantes, Barbara
Klupp, Elisabeth
Ganter, Carl
Kooijman, Hendrik
Rummeny, Ernst J.
Zimmer, Claus
Kirschke, Jan S.
Karampinos, Dimitrios C.
author_sort Sollmann, Nico
collection PubMed
description PURPOSE: Isotropic high-resolution three-dimensional (3D) magnetic resonance neurography (MRN) is increasingly used to depict even small and highly oblique nerves of the lumbosacral plexus (LSP). The present study introduces a T2 mapping sequence (T2-prepared 3D turbo spin echo) that is B1-insensitive and enables quantitative assessment of LSP nerves. METHODS: In this study 15 healthy subjects (mean age 28.5 ± 3.8 years) underwent 3 T MRN of the LSP area three times. The T2 values were calculated offline on a voxel-by-voxel basis and measured at three segments (preganglionic, ganglionic, postganglionic) of three LSP nerves (S1, L5, L4) by two independent investigators (experienced and novice). Normative data for the different nerves were extracted and intraclass correlation coefficients (ICCs) were calculated to assess reproducibility and interobserver reliability of T2 measurements. RESULTS: The T2 mapping showed excellent reproducibility with ICCs ranging between 0.99 (S1 preganglionic) and 0.89 (L5 postganglionic). Interobserver reliability was less robust with ICCs ranging between 0.78 (S1 preganglionic) and 0.44 (L5 postganglionic) for S1 and L5. A mean T2 value of 74.6 ± 4.7 ms was registered for preganglionic segments, 84.7 ± 4.1 ms for ganglionic and 65.4 ± 2.5 ms for postganglionic segments, respectively. There was a statistically significant variation of T2 values across the nerve (preganglionic vs ganglionic vs postganglionic) for S1, L5, and L4. CONCLUSION: Our approach enables isotropic high-resolution and B1-insensitive T2 mapping of LSP nerves with excellent reproducibility. It might reflect a robust and clinically useful method for future diagnostics of LSP pathologies. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00062-017-0658-9) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6579865
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-65798652019-07-03 High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo Sollmann, Nico Weidlich, Dominik Cervantes, Barbara Klupp, Elisabeth Ganter, Carl Kooijman, Hendrik Rummeny, Ernst J. Zimmer, Claus Kirschke, Jan S. Karampinos, Dimitrios C. Clin Neuroradiol Original Article PURPOSE: Isotropic high-resolution three-dimensional (3D) magnetic resonance neurography (MRN) is increasingly used to depict even small and highly oblique nerves of the lumbosacral plexus (LSP). The present study introduces a T2 mapping sequence (T2-prepared 3D turbo spin echo) that is B1-insensitive and enables quantitative assessment of LSP nerves. METHODS: In this study 15 healthy subjects (mean age 28.5 ± 3.8 years) underwent 3 T MRN of the LSP area three times. The T2 values were calculated offline on a voxel-by-voxel basis and measured at three segments (preganglionic, ganglionic, postganglionic) of three LSP nerves (S1, L5, L4) by two independent investigators (experienced and novice). Normative data for the different nerves were extracted and intraclass correlation coefficients (ICCs) were calculated to assess reproducibility and interobserver reliability of T2 measurements. RESULTS: The T2 mapping showed excellent reproducibility with ICCs ranging between 0.99 (S1 preganglionic) and 0.89 (L5 postganglionic). Interobserver reliability was less robust with ICCs ranging between 0.78 (S1 preganglionic) and 0.44 (L5 postganglionic) for S1 and L5. A mean T2 value of 74.6 ± 4.7 ms was registered for preganglionic segments, 84.7 ± 4.1 ms for ganglionic and 65.4 ± 2.5 ms for postganglionic segments, respectively. There was a statistically significant variation of T2 values across the nerve (preganglionic vs ganglionic vs postganglionic) for S1, L5, and L4. CONCLUSION: Our approach enables isotropic high-resolution and B1-insensitive T2 mapping of LSP nerves with excellent reproducibility. It might reflect a robust and clinically useful method for future diagnostics of LSP pathologies. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00062-017-0658-9) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2018-01-10 2019 /pmc/articles/PMC6579865/ /pubmed/29322233 http://dx.doi.org/10.1007/s00062-017-0658-9 Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Sollmann, Nico
Weidlich, Dominik
Cervantes, Barbara
Klupp, Elisabeth
Ganter, Carl
Kooijman, Hendrik
Rummeny, Ernst J.
Zimmer, Claus
Kirschke, Jan S.
Karampinos, Dimitrios C.
High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo
title High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo
title_full High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo
title_fullStr High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo
title_full_unstemmed High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo
title_short High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo
title_sort high isotropic resolution t2 mapping of the lumbosacral plexus with t2-prepared 3d turbo spin echo
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6579865/
https://www.ncbi.nlm.nih.gov/pubmed/29322233
http://dx.doi.org/10.1007/s00062-017-0658-9
work_keys_str_mv AT sollmannnico highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho
AT weidlichdominik highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho
AT cervantesbarbara highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho
AT kluppelisabeth highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho
AT gantercarl highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho
AT kooijmanhendrik highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho
AT rummenyernstj highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho
AT zimmerclaus highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho
AT kirschkejans highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho
AT karampinosdimitriosc highisotropicresolutiont2mappingofthelumbosacralplexuswitht2prepared3dturbospinecho