Computed tomographic evaluation of novel custom-made artificial bones, “CT-bone”, applied for maxillofacial reconstruction

INTRODUCTION: We fabricated custom-made artificial bones using three-dimensionally layered manufacturing (3D printing) process, and have applied them to patients with facial deformities. We termed this novel artificial bone the “CT-bone”. The aim of the present study was to evaluate the middle- and...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanno, Yuki, Nakatsuka, Takashi, Saijo, Hideto, Fujihara, Yuko, Atsuhiko, Hikita, Chung, Ung-il, Takato, Tsuyoshi, Hoshi, Kazuto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Regenerative Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6581798/
https://www.ncbi.nlm.nih.gov/pubmed/31245494
http://dx.doi.org/10.1016/j.reth.2016.05.002
_version_ 1783428215244587008
author Kanno, Yuki
Nakatsuka, Takashi
Saijo, Hideto
Fujihara, Yuko
Atsuhiko, Hikita
Chung, Ung-il
Takato, Tsuyoshi
Hoshi, Kazuto
author_facet Kanno, Yuki
Nakatsuka, Takashi
Saijo, Hideto
Fujihara, Yuko
Atsuhiko, Hikita
Chung, Ung-il
Takato, Tsuyoshi
Hoshi, Kazuto
author_sort Kanno, Yuki
collection PubMed
description INTRODUCTION: We fabricated custom-made artificial bones using three-dimensionally layered manufacturing (3D printing) process, and have applied them to patients with facial deformities. We termed this novel artificial bone the “CT-bone”. The aim of the present study was to evaluate the middle- and long-term safety and effectiveness of the CT-bones after transplantation. METHODS: The subject areas involved were 23 sites of 20 patients with facial bone deformities due to congenital abnormality, tumor, or trauma. The CT-bones were used for augmentation; they were evaluated by CT images, minimally for 1 year and maximally for 7 years and 3 months (3 years and 1 month on average) after transplantation. RESULTS: No serious systemic events due to the CT-bone graft were found during the observation period (1 year postoperatively). In 4 sites of 4 patients, the CT-bones were removed due to local infection of the surgical wounds at 1–5 years postoperatively. Compatibility of the shapes between the CT-bone and the recipient bone was confirmed to be good during the operation in all of the 20 cases, implying that the CT-bones could be easily installed onto the recipient sites. During the CT evaluation (<7 years and 3 months), no apparent chronological change was seen in the shape of the CT-bones. Sufficient bone union was confirmed in 19 sites. The inner CT values of the CT-bones increased in all the sites. The longer the postoperative period, greater increases in the CT values of the CT-bones tended to be observed. CONCLUSIONS: The CT-bone showed maintenance of the original shape and good bone replacement, based on the middle- and long-term follow-ups. In the future, we would make an intelligent type of artificial bones in which bone regeneration is induced by gradually releasing angiogenesis-inducing factors and/or bone-regeneration-inducing factors at the three-dimensionally controlled positions.
format Online
Article
Text
id pubmed-6581798
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Japanese Society for Regenerative Medicine
record_format MEDLINE/PubMed
spelling pubmed-65817982019-06-26 Computed tomographic evaluation of novel custom-made artificial bones, “CT-bone”, applied for maxillofacial reconstruction Kanno, Yuki Nakatsuka, Takashi Saijo, Hideto Fujihara, Yuko Atsuhiko, Hikita Chung, Ung-il Takato, Tsuyoshi Hoshi, Kazuto Regen Ther Original Article INTRODUCTION: We fabricated custom-made artificial bones using three-dimensionally layered manufacturing (3D printing) process, and have applied them to patients with facial deformities. We termed this novel artificial bone the “CT-bone”. The aim of the present study was to evaluate the middle- and long-term safety and effectiveness of the CT-bones after transplantation. METHODS: The subject areas involved were 23 sites of 20 patients with facial bone deformities due to congenital abnormality, tumor, or trauma. The CT-bones were used for augmentation; they were evaluated by CT images, minimally for 1 year and maximally for 7 years and 3 months (3 years and 1 month on average) after transplantation. RESULTS: No serious systemic events due to the CT-bone graft were found during the observation period (1 year postoperatively). In 4 sites of 4 patients, the CT-bones were removed due to local infection of the surgical wounds at 1–5 years postoperatively. Compatibility of the shapes between the CT-bone and the recipient bone was confirmed to be good during the operation in all of the 20 cases, implying that the CT-bones could be easily installed onto the recipient sites. During the CT evaluation (<7 years and 3 months), no apparent chronological change was seen in the shape of the CT-bones. Sufficient bone union was confirmed in 19 sites. The inner CT values of the CT-bones increased in all the sites. The longer the postoperative period, greater increases in the CT values of the CT-bones tended to be observed. CONCLUSIONS: The CT-bone showed maintenance of the original shape and good bone replacement, based on the middle- and long-term follow-ups. In the future, we would make an intelligent type of artificial bones in which bone regeneration is induced by gradually releasing angiogenesis-inducing factors and/or bone-regeneration-inducing factors at the three-dimensionally controlled positions. Japanese Society for Regenerative Medicine 2016-07-01 /pmc/articles/PMC6581798/ /pubmed/31245494 http://dx.doi.org/10.1016/j.reth.2016.05.002 Text en © 2016, The Japanese Society for Regenerative Medicine. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Kanno, Yuki
Nakatsuka, Takashi
Saijo, Hideto
Fujihara, Yuko
Atsuhiko, Hikita
Chung, Ung-il
Takato, Tsuyoshi
Hoshi, Kazuto
Computed tomographic evaluation of novel custom-made artificial bones, “CT-bone”, applied for maxillofacial reconstruction
title Computed tomographic evaluation of novel custom-made artificial bones, “CT-bone”, applied for maxillofacial reconstruction
title_full Computed tomographic evaluation of novel custom-made artificial bones, “CT-bone”, applied for maxillofacial reconstruction
title_fullStr Computed tomographic evaluation of novel custom-made artificial bones, “CT-bone”, applied for maxillofacial reconstruction
title_full_unstemmed Computed tomographic evaluation of novel custom-made artificial bones, “CT-bone”, applied for maxillofacial reconstruction
title_short Computed tomographic evaluation of novel custom-made artificial bones, “CT-bone”, applied for maxillofacial reconstruction
title_sort computed tomographic evaluation of novel custom-made artificial bones, “ct-bone”, applied for maxillofacial reconstruction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6581798/
https://www.ncbi.nlm.nih.gov/pubmed/31245494
http://dx.doi.org/10.1016/j.reth.2016.05.002
work_keys_str_mv AT kannoyuki computedtomographicevaluationofnovelcustommadeartificialbonesctboneappliedformaxillofacialreconstruction
AT nakatsukatakashi computedtomographicevaluationofnovelcustommadeartificialbonesctboneappliedformaxillofacialreconstruction
AT saijohideto computedtomographicevaluationofnovelcustommadeartificialbonesctboneappliedformaxillofacialreconstruction
AT fujiharayuko computedtomographicevaluationofnovelcustommadeartificialbonesctboneappliedformaxillofacialreconstruction
AT atsuhikohikita computedtomographicevaluationofnovelcustommadeartificialbonesctboneappliedformaxillofacialreconstruction
AT chungungil computedtomographicevaluationofnovelcustommadeartificialbonesctboneappliedformaxillofacialreconstruction
AT takatotsuyoshi computedtomographicevaluationofnovelcustommadeartificialbonesctboneappliedformaxillofacialreconstruction
AT hoshikazuto computedtomographicevaluationofnovelcustommadeartificialbonesctboneappliedformaxillofacialreconstruction