Cargando…

Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue

Introduction: Functional electrical stimulation is a common technique used in the rehabilitation of individuals with a spinal cord injury to produce functional movement of paralysed muscles. However, it is often associated with rapid muscle fatigue which limits its applications. Methods: The objecti...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruslee, Ruslinda, Miller, Jennifer, Gollee, Henrik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6582293/
https://www.ncbi.nlm.nih.gov/pubmed/31245029
http://dx.doi.org/10.1177/2055668319825808
_version_ 1783428293043683328
author Ruslee, Ruslinda
Miller, Jennifer
Gollee, Henrik
author_facet Ruslee, Ruslinda
Miller, Jennifer
Gollee, Henrik
author_sort Ruslee, Ruslinda
collection PubMed
description Introduction: Functional electrical stimulation is a common technique used in the rehabilitation of individuals with a spinal cord injury to produce functional movement of paralysed muscles. However, it is often associated with rapid muscle fatigue which limits its applications. Methods: The objective of this study is to investigate the effects on the onset of fatigue of different multi-electrode patterns of stimulation via multiple pairs of electrodes using doublet pulses: Synchronous stimulation is compared to asynchronous stimulation patterns which are activated sequentially (AsynS) or randomly (AsynR), mimicking voluntary muscle activation by targeting different motor units. We investigated these three different approaches by applying stimulation to the gastrocnemius muscle repeatedly for 10 min (300 ms stimulation followed by 700 ms of no-stimulation) with 40 Hz effective frequency for all protocols and doublet pulses with an inter-pulse-interval of 6 ms. Eleven able-bodied volunteers (28 ± 3 years old) participated in this study. Ultrasound videos were recorded during stimulation to allow evaluation of changes in muscle morphology. The main fatigue indicators we focused on were the normalised fatigue index, fatigue time interval and pre-post twitch–tetanus ratio. Results: The results demonstrate that asynchronous stimulation with doublet pulses gives a higher normalised fatigue index (0.80 ± 0.08 and 0.87 ± 0.08) for AsynS and AsynR, respectively, than synchronous stimulation (0.62 ± 0.06). Furthermore, a longer fatigue time interval for AsynS (302.2 ± 230.9 s) and AsynR (384.4 ± 279.0 s) compared to synchronous stimulation (68.0 ± 30.5 s) indicates that fatigue occurs later during asynchronous stimulation; however, this was only found to be statistically significant for one of two methods used to calculate the group mean. Although no significant difference was found in pre-post twitch–tetanus ratio, there was a trend towards these effects. Conclusion: In this study, we proposed an asynchronous stimulation pattern for the application of functional electrical stimulation and investigated its suitability for reducing muscle fatigue compared to previous methods. The results show that asynchronous multi-electrode stimulation patterns with doublet pulses may improve fatigue resistance in functional electrical stimulation applications in some conditions.
format Online
Article
Text
id pubmed-6582293
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-65822932019-06-26 Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue Ruslee, Ruslinda Miller, Jennifer Gollee, Henrik J Rehabil Assist Technol Eng IFESS 2017 Introduction: Functional electrical stimulation is a common technique used in the rehabilitation of individuals with a spinal cord injury to produce functional movement of paralysed muscles. However, it is often associated with rapid muscle fatigue which limits its applications. Methods: The objective of this study is to investigate the effects on the onset of fatigue of different multi-electrode patterns of stimulation via multiple pairs of electrodes using doublet pulses: Synchronous stimulation is compared to asynchronous stimulation patterns which are activated sequentially (AsynS) or randomly (AsynR), mimicking voluntary muscle activation by targeting different motor units. We investigated these three different approaches by applying stimulation to the gastrocnemius muscle repeatedly for 10 min (300 ms stimulation followed by 700 ms of no-stimulation) with 40 Hz effective frequency for all protocols and doublet pulses with an inter-pulse-interval of 6 ms. Eleven able-bodied volunteers (28 ± 3 years old) participated in this study. Ultrasound videos were recorded during stimulation to allow evaluation of changes in muscle morphology. The main fatigue indicators we focused on were the normalised fatigue index, fatigue time interval and pre-post twitch–tetanus ratio. Results: The results demonstrate that asynchronous stimulation with doublet pulses gives a higher normalised fatigue index (0.80 ± 0.08 and 0.87 ± 0.08) for AsynS and AsynR, respectively, than synchronous stimulation (0.62 ± 0.06). Furthermore, a longer fatigue time interval for AsynS (302.2 ± 230.9 s) and AsynR (384.4 ± 279.0 s) compared to synchronous stimulation (68.0 ± 30.5 s) indicates that fatigue occurs later during asynchronous stimulation; however, this was only found to be statistically significant for one of two methods used to calculate the group mean. Although no significant difference was found in pre-post twitch–tetanus ratio, there was a trend towards these effects. Conclusion: In this study, we proposed an asynchronous stimulation pattern for the application of functional electrical stimulation and investigated its suitability for reducing muscle fatigue compared to previous methods. The results show that asynchronous multi-electrode stimulation patterns with doublet pulses may improve fatigue resistance in functional electrical stimulation applications in some conditions. SAGE Publications 2019-03-22 /pmc/articles/PMC6582293/ /pubmed/31245029 http://dx.doi.org/10.1177/2055668319825808 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle IFESS 2017
Ruslee, Ruslinda
Miller, Jennifer
Gollee, Henrik
Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue
title Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue
title_full Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue
title_fullStr Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue
title_full_unstemmed Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue
title_short Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue
title_sort investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue
topic IFESS 2017
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6582293/
https://www.ncbi.nlm.nih.gov/pubmed/31245029
http://dx.doi.org/10.1177/2055668319825808
work_keys_str_mv AT rusleeruslinda investigationofdifferentstimulationpatternswithdoubletpulsestoreducemusclefatigue
AT millerjennifer investigationofdifferentstimulationpatternswithdoubletpulsestoreducemusclefatigue
AT golleehenrik investigationofdifferentstimulationpatternswithdoubletpulsestoreducemusclefatigue