Cargando…
Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue
Introduction: Functional electrical stimulation is a common technique used in the rehabilitation of individuals with a spinal cord injury to produce functional movement of paralysed muscles. However, it is often associated with rapid muscle fatigue which limits its applications. Methods: The objecti...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6582293/ https://www.ncbi.nlm.nih.gov/pubmed/31245029 http://dx.doi.org/10.1177/2055668319825808 |
_version_ | 1783428293043683328 |
---|---|
author | Ruslee, Ruslinda Miller, Jennifer Gollee, Henrik |
author_facet | Ruslee, Ruslinda Miller, Jennifer Gollee, Henrik |
author_sort | Ruslee, Ruslinda |
collection | PubMed |
description | Introduction: Functional electrical stimulation is a common technique used in the rehabilitation of individuals with a spinal cord injury to produce functional movement of paralysed muscles. However, it is often associated with rapid muscle fatigue which limits its applications. Methods: The objective of this study is to investigate the effects on the onset of fatigue of different multi-electrode patterns of stimulation via multiple pairs of electrodes using doublet pulses: Synchronous stimulation is compared to asynchronous stimulation patterns which are activated sequentially (AsynS) or randomly (AsynR), mimicking voluntary muscle activation by targeting different motor units. We investigated these three different approaches by applying stimulation to the gastrocnemius muscle repeatedly for 10 min (300 ms stimulation followed by 700 ms of no-stimulation) with 40 Hz effective frequency for all protocols and doublet pulses with an inter-pulse-interval of 6 ms. Eleven able-bodied volunteers (28 ± 3 years old) participated in this study. Ultrasound videos were recorded during stimulation to allow evaluation of changes in muscle morphology. The main fatigue indicators we focused on were the normalised fatigue index, fatigue time interval and pre-post twitch–tetanus ratio. Results: The results demonstrate that asynchronous stimulation with doublet pulses gives a higher normalised fatigue index (0.80 ± 0.08 and 0.87 ± 0.08) for AsynS and AsynR, respectively, than synchronous stimulation (0.62 ± 0.06). Furthermore, a longer fatigue time interval for AsynS (302.2 ± 230.9 s) and AsynR (384.4 ± 279.0 s) compared to synchronous stimulation (68.0 ± 30.5 s) indicates that fatigue occurs later during asynchronous stimulation; however, this was only found to be statistically significant for one of two methods used to calculate the group mean. Although no significant difference was found in pre-post twitch–tetanus ratio, there was a trend towards these effects. Conclusion: In this study, we proposed an asynchronous stimulation pattern for the application of functional electrical stimulation and investigated its suitability for reducing muscle fatigue compared to previous methods. The results show that asynchronous multi-electrode stimulation patterns with doublet pulses may improve fatigue resistance in functional electrical stimulation applications in some conditions. |
format | Online Article Text |
id | pubmed-6582293 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-65822932019-06-26 Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue Ruslee, Ruslinda Miller, Jennifer Gollee, Henrik J Rehabil Assist Technol Eng IFESS 2017 Introduction: Functional electrical stimulation is a common technique used in the rehabilitation of individuals with a spinal cord injury to produce functional movement of paralysed muscles. However, it is often associated with rapid muscle fatigue which limits its applications. Methods: The objective of this study is to investigate the effects on the onset of fatigue of different multi-electrode patterns of stimulation via multiple pairs of electrodes using doublet pulses: Synchronous stimulation is compared to asynchronous stimulation patterns which are activated sequentially (AsynS) or randomly (AsynR), mimicking voluntary muscle activation by targeting different motor units. We investigated these three different approaches by applying stimulation to the gastrocnemius muscle repeatedly for 10 min (300 ms stimulation followed by 700 ms of no-stimulation) with 40 Hz effective frequency for all protocols and doublet pulses with an inter-pulse-interval of 6 ms. Eleven able-bodied volunteers (28 ± 3 years old) participated in this study. Ultrasound videos were recorded during stimulation to allow evaluation of changes in muscle morphology. The main fatigue indicators we focused on were the normalised fatigue index, fatigue time interval and pre-post twitch–tetanus ratio. Results: The results demonstrate that asynchronous stimulation with doublet pulses gives a higher normalised fatigue index (0.80 ± 0.08 and 0.87 ± 0.08) for AsynS and AsynR, respectively, than synchronous stimulation (0.62 ± 0.06). Furthermore, a longer fatigue time interval for AsynS (302.2 ± 230.9 s) and AsynR (384.4 ± 279.0 s) compared to synchronous stimulation (68.0 ± 30.5 s) indicates that fatigue occurs later during asynchronous stimulation; however, this was only found to be statistically significant for one of two methods used to calculate the group mean. Although no significant difference was found in pre-post twitch–tetanus ratio, there was a trend towards these effects. Conclusion: In this study, we proposed an asynchronous stimulation pattern for the application of functional electrical stimulation and investigated its suitability for reducing muscle fatigue compared to previous methods. The results show that asynchronous multi-electrode stimulation patterns with doublet pulses may improve fatigue resistance in functional electrical stimulation applications in some conditions. SAGE Publications 2019-03-22 /pmc/articles/PMC6582293/ /pubmed/31245029 http://dx.doi.org/10.1177/2055668319825808 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | IFESS 2017 Ruslee, Ruslinda Miller, Jennifer Gollee, Henrik Investigation of different stimulation patterns with doublet pulses to reduce muscle fatigue |
title | Investigation of different stimulation patterns with doublet pulses
to reduce muscle fatigue |
title_full | Investigation of different stimulation patterns with doublet pulses
to reduce muscle fatigue |
title_fullStr | Investigation of different stimulation patterns with doublet pulses
to reduce muscle fatigue |
title_full_unstemmed | Investigation of different stimulation patterns with doublet pulses
to reduce muscle fatigue |
title_short | Investigation of different stimulation patterns with doublet pulses
to reduce muscle fatigue |
title_sort | investigation of different stimulation patterns with doublet pulses
to reduce muscle fatigue |
topic | IFESS 2017 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6582293/ https://www.ncbi.nlm.nih.gov/pubmed/31245029 http://dx.doi.org/10.1177/2055668319825808 |
work_keys_str_mv | AT rusleeruslinda investigationofdifferentstimulationpatternswithdoubletpulsestoreducemusclefatigue AT millerjennifer investigationofdifferentstimulationpatternswithdoubletpulsestoreducemusclefatigue AT golleehenrik investigationofdifferentstimulationpatternswithdoubletpulsestoreducemusclefatigue |