Cargando…

Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles

AIM: To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. METHODS: Thirty-one edentulous patients received two narrow implants (2.9x10mm, Fac...

Descripción completa

Detalles Bibliográficos
Autores principales: Faot, Fernanda, Bielemann, Amália Machado, Schuster, Alessandra Julie, Marcello-Machado, Raissa Micaella, Del Bel Cury, Altair Antoninha, Nascimento, Gustavo G., Chagas-Junior, Otacílio Luiz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6582836/
https://www.ncbi.nlm.nih.gov/pubmed/31275984
http://dx.doi.org/10.1155/2019/8132520
_version_ 1783428407401381888
author Faot, Fernanda
Bielemann, Amália Machado
Schuster, Alessandra Julie
Marcello-Machado, Raissa Micaella
Del Bel Cury, Altair Antoninha
Nascimento, Gustavo G.
Chagas-Junior, Otacílio Luiz
author_facet Faot, Fernanda
Bielemann, Amália Machado
Schuster, Alessandra Julie
Marcello-Machado, Raissa Micaella
Del Bel Cury, Altair Antoninha
Nascimento, Gustavo G.
Chagas-Junior, Otacílio Luiz
author_sort Faot, Fernanda
collection PubMed
description AIM: To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. METHODS: Thirty-one edentulous patients received two narrow implants (2.9x10mm, Facility NeoPoros) to retain mandibular overdentures. The implants were categorized in four groups according to their IT: (G1) IT > 10 Ncm; (G2) IT ≥ 10Ncm and ≤ 30 Ncm; (G3) IT >30Ncm and < 45Ncm; (G4) IT ≥ 45Ncm, and all implants were loaded after 3 months of healing. The following clinical outcomes were evaluated 1, 3, 6, and 12 months after implant insertion: (i) peri-implant tissue health (PH), gingival index (GI), plaque index (PI), calculus presence (CP), probing depth (PD), and bleeding on probing (BOP); (ii) implant stability quotient (ISQ) by resonance frequency analysis; and (iii) IL-1β and TNF-α concentration in the peri-implant crevicular fluid. The marginal bone level (MBL) and changes (MBC) were evaluated. The Chi(2) test, Kruskal-Wallis test, mixed-effects regression analysis, and the Kendall rank correlation coefficient were used for statistical analysis (α = 5%). RESULTS: G1 presented the highest PD at all evaluated periods. G2 presented higher PI at month 6 and 12. G4 showed increased GI at month 3 and 12 and more CP at month 1 (p=.003). G2 and G4 had higher ISQ values over the study period, while those from G1 and G3 presented lower ISQ values. The IL-1β concentration increased until month 12 and was independent of IT and bone type; G4 had a higher IL-1β concentration in month 3 than the other groups (p=.015). The TNF-α release was negatively correlated with IT, and TNF-α release was highest in G1 at month 12. The MBL immediately after surgery and the MBC at month 12 were similar between the groups, and G4 presented a positive MBC at month 12. The survival and success rates were 75% for G1, 81.3% for G2, 64.3% for G3, and 95% for G4. CONCLUSION: The IT did not influence the clinical outcomes and the peri-implant immunoinflammatory responses and was weakly correlated with the narrow dental implants primary stability. The observed success rates suggest that the ideal IT for atrophic fully edentulous patients may deviate from the standardized IT of 32 Ncm.
format Online
Article
Text
id pubmed-6582836
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-65828362019-07-04 Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles Faot, Fernanda Bielemann, Amália Machado Schuster, Alessandra Julie Marcello-Machado, Raissa Micaella Del Bel Cury, Altair Antoninha Nascimento, Gustavo G. Chagas-Junior, Otacílio Luiz Biomed Res Int Research Article AIM: To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. METHODS: Thirty-one edentulous patients received two narrow implants (2.9x10mm, Facility NeoPoros) to retain mandibular overdentures. The implants were categorized in four groups according to their IT: (G1) IT > 10 Ncm; (G2) IT ≥ 10Ncm and ≤ 30 Ncm; (G3) IT >30Ncm and < 45Ncm; (G4) IT ≥ 45Ncm, and all implants were loaded after 3 months of healing. The following clinical outcomes were evaluated 1, 3, 6, and 12 months after implant insertion: (i) peri-implant tissue health (PH), gingival index (GI), plaque index (PI), calculus presence (CP), probing depth (PD), and bleeding on probing (BOP); (ii) implant stability quotient (ISQ) by resonance frequency analysis; and (iii) IL-1β and TNF-α concentration in the peri-implant crevicular fluid. The marginal bone level (MBL) and changes (MBC) were evaluated. The Chi(2) test, Kruskal-Wallis test, mixed-effects regression analysis, and the Kendall rank correlation coefficient were used for statistical analysis (α = 5%). RESULTS: G1 presented the highest PD at all evaluated periods. G2 presented higher PI at month 6 and 12. G4 showed increased GI at month 3 and 12 and more CP at month 1 (p=.003). G2 and G4 had higher ISQ values over the study period, while those from G1 and G3 presented lower ISQ values. The IL-1β concentration increased until month 12 and was independent of IT and bone type; G4 had a higher IL-1β concentration in month 3 than the other groups (p=.015). The TNF-α release was negatively correlated with IT, and TNF-α release was highest in G1 at month 12. The MBL immediately after surgery and the MBC at month 12 were similar between the groups, and G4 presented a positive MBC at month 12. The survival and success rates were 75% for G1, 81.3% for G2, 64.3% for G3, and 95% for G4. CONCLUSION: The IT did not influence the clinical outcomes and the peri-implant immunoinflammatory responses and was weakly correlated with the narrow dental implants primary stability. The observed success rates suggest that the ideal IT for atrophic fully edentulous patients may deviate from the standardized IT of 32 Ncm. Hindawi 2019-06-02 /pmc/articles/PMC6582836/ /pubmed/31275984 http://dx.doi.org/10.1155/2019/8132520 Text en Copyright © 2019 Fernanda Faot et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Faot, Fernanda
Bielemann, Amália Machado
Schuster, Alessandra Julie
Marcello-Machado, Raissa Micaella
Del Bel Cury, Altair Antoninha
Nascimento, Gustavo G.
Chagas-Junior, Otacílio Luiz
Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_full Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_fullStr Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_full_unstemmed Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_short Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
title_sort influence of insertion torque on clinical and biological outcomes before and after loading of mandibular implant-retained overdentures in atrophic edentulous mandibles
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6582836/
https://www.ncbi.nlm.nih.gov/pubmed/31275984
http://dx.doi.org/10.1155/2019/8132520
work_keys_str_mv AT faotfernanda influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT bielemannamaliamachado influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT schusteralessandrajulie influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT marcellomachadoraissamicaella influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT delbelcuryaltairantoninha influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT nascimentogustavog influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles
AT chagasjuniorotacilioluiz influenceofinsertiontorqueonclinicalandbiologicaloutcomesbeforeandafterloadingofmandibularimplantretainedoverdenturesinatrophicedentulousmandibles