Cargando…

Long-term use of noble metal alloy coated urinary catheters reduces recurrent CAUTI and decreases proinflammatory markers

BACKGROUND: The objective of this study was to investigate a case of a permanently (suprapubic) catheterized woman with neurogenic bladder dysfunction. The patient had suffered from recurrent catheter-associated urinary tract infections (CAUTIs) since 2009, despite several prevention approaches and...

Descripción completa

Detalles Bibliográficos
Autores principales: Magnusson, Birgitta, Kai-Larsen, Ylva, Granlund, Petter, Seiger, Åke, Lindbo, Lena, Sanchez, Javier, Johansson, Dorota
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6585253/
https://www.ncbi.nlm.nih.gov/pubmed/31258625
http://dx.doi.org/10.1177/1756287219854915
_version_ 1783428671680282624
author Magnusson, Birgitta
Kai-Larsen, Ylva
Granlund, Petter
Seiger, Åke
Lindbo, Lena
Sanchez, Javier
Johansson, Dorota
author_facet Magnusson, Birgitta
Kai-Larsen, Ylva
Granlund, Petter
Seiger, Åke
Lindbo, Lena
Sanchez, Javier
Johansson, Dorota
author_sort Magnusson, Birgitta
collection PubMed
description BACKGROUND: The objective of this study was to investigate a case of a permanently (suprapubic) catheterized woman with neurogenic bladder dysfunction. The patient had suffered from recurrent catheter-associated urinary tract infections (CAUTIs) since 2009, despite several prevention approaches and attempts. In 2013, the patient’s catheter was substituted for the BIP Foley Catheter, coated with a noble metal alloy (NMA) of gold, silver, and palladium. METHOD: This is a retrospective–prospective clinical case study covering 4 years history for the control catheters and up to 2.5 years for the anti-infective BIP Foley Catheter. CAUTI incidences, symptoms, antibiotics, catheter performance, and comfort were evaluated. Levels of proinflammatory cytokines were measured pre- and post-substitution to BIP Foley Catheter in urine of the case and of four other permanently catheterized patients. In addition, the levels of noble metals were assessed in urine of the case subject during use of the BIP Foley Catheter. RESULTS: While using control catheters, the patient experienced symptomatic CAUTIs requiring antibiotics almost every month for 4 years. After 1 month with the BIP Foley Catheter, the symptoms disappeared, and the patient remained free of symptomatic CAUTIs and antibiotic treatment for the following 2.5 years, despite bacteriuria. The patient was satisfied with the comfort during insertion, use, and removal of the BIP Foley Catheter. Urinary levels of the proinflammatory cytokines interleukin (IL)-6, IL-8, and tumor necrosis factor alpha (TNFα) decreased towards normal levels post catheter type substitution. Traces of noble metals detected in a few urine samples were ⩽4% of the permitted daily exposure. The levels of the noble metals gold, silver, and palladium remaining on the BIP Foley Catheter after use were the same as for unused catheters. CONCLUSION: Long-term use of a NMA-coated catheter was associated with cessation of frequent CAUTIs. The catheter was experienced as comfortable and inflammatory markers were reduced with time. The coating was stable, with no significant metal release into urine and is therefore safe for patient use.
format Online
Article
Text
id pubmed-6585253
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-65852532019-06-28 Long-term use of noble metal alloy coated urinary catheters reduces recurrent CAUTI and decreases proinflammatory markers Magnusson, Birgitta Kai-Larsen, Ylva Granlund, Petter Seiger, Åke Lindbo, Lena Sanchez, Javier Johansson, Dorota Ther Adv Urol Original Research BACKGROUND: The objective of this study was to investigate a case of a permanently (suprapubic) catheterized woman with neurogenic bladder dysfunction. The patient had suffered from recurrent catheter-associated urinary tract infections (CAUTIs) since 2009, despite several prevention approaches and attempts. In 2013, the patient’s catheter was substituted for the BIP Foley Catheter, coated with a noble metal alloy (NMA) of gold, silver, and palladium. METHOD: This is a retrospective–prospective clinical case study covering 4 years history for the control catheters and up to 2.5 years for the anti-infective BIP Foley Catheter. CAUTI incidences, symptoms, antibiotics, catheter performance, and comfort were evaluated. Levels of proinflammatory cytokines were measured pre- and post-substitution to BIP Foley Catheter in urine of the case and of four other permanently catheterized patients. In addition, the levels of noble metals were assessed in urine of the case subject during use of the BIP Foley Catheter. RESULTS: While using control catheters, the patient experienced symptomatic CAUTIs requiring antibiotics almost every month for 4 years. After 1 month with the BIP Foley Catheter, the symptoms disappeared, and the patient remained free of symptomatic CAUTIs and antibiotic treatment for the following 2.5 years, despite bacteriuria. The patient was satisfied with the comfort during insertion, use, and removal of the BIP Foley Catheter. Urinary levels of the proinflammatory cytokines interleukin (IL)-6, IL-8, and tumor necrosis factor alpha (TNFα) decreased towards normal levels post catheter type substitution. Traces of noble metals detected in a few urine samples were ⩽4% of the permitted daily exposure. The levels of the noble metals gold, silver, and palladium remaining on the BIP Foley Catheter after use were the same as for unused catheters. CONCLUSION: Long-term use of a NMA-coated catheter was associated with cessation of frequent CAUTIs. The catheter was experienced as comfortable and inflammatory markers were reduced with time. The coating was stable, with no significant metal release into urine and is therefore safe for patient use. SAGE Publications 2019-06-18 /pmc/articles/PMC6585253/ /pubmed/31258625 http://dx.doi.org/10.1177/1756287219854915 Text en © The Author(s), 2019 http://www.creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Magnusson, Birgitta
Kai-Larsen, Ylva
Granlund, Petter
Seiger, Åke
Lindbo, Lena
Sanchez, Javier
Johansson, Dorota
Long-term use of noble metal alloy coated urinary catheters reduces recurrent CAUTI and decreases proinflammatory markers
title Long-term use of noble metal alloy coated urinary catheters reduces recurrent CAUTI and decreases proinflammatory markers
title_full Long-term use of noble metal alloy coated urinary catheters reduces recurrent CAUTI and decreases proinflammatory markers
title_fullStr Long-term use of noble metal alloy coated urinary catheters reduces recurrent CAUTI and decreases proinflammatory markers
title_full_unstemmed Long-term use of noble metal alloy coated urinary catheters reduces recurrent CAUTI and decreases proinflammatory markers
title_short Long-term use of noble metal alloy coated urinary catheters reduces recurrent CAUTI and decreases proinflammatory markers
title_sort long-term use of noble metal alloy coated urinary catheters reduces recurrent cauti and decreases proinflammatory markers
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6585253/
https://www.ncbi.nlm.nih.gov/pubmed/31258625
http://dx.doi.org/10.1177/1756287219854915
work_keys_str_mv AT magnussonbirgitta longtermuseofnoblemetalalloycoatedurinarycathetersreducesrecurrentcautianddecreasesproinflammatorymarkers
AT kailarsenylva longtermuseofnoblemetalalloycoatedurinarycathetersreducesrecurrentcautianddecreasesproinflammatorymarkers
AT granlundpetter longtermuseofnoblemetalalloycoatedurinarycathetersreducesrecurrentcautianddecreasesproinflammatorymarkers
AT seigerake longtermuseofnoblemetalalloycoatedurinarycathetersreducesrecurrentcautianddecreasesproinflammatorymarkers
AT lindbolena longtermuseofnoblemetalalloycoatedurinarycathetersreducesrecurrentcautianddecreasesproinflammatorymarkers
AT sanchezjavier longtermuseofnoblemetalalloycoatedurinarycathetersreducesrecurrentcautianddecreasesproinflammatorymarkers
AT johanssondorota longtermuseofnoblemetalalloycoatedurinarycathetersreducesrecurrentcautianddecreasesproinflammatorymarkers