Cargando…

Optic nerve head morphology in primary open‐angle glaucoma and nonarteritic anterior ischaemic optic neuropathy measured with spectral domain optical coherence tomography

PURPOSE: Optic nerve head (ONH) parameters as well as circumpapillary retinal nerve fibre layer (RNFL) thickness values measured with two different spectral domain optical coherence tomography (SD‐OCT) machines (Spectralis(®) and Cirrus(®) OCT) have been compared between two patient groups, primary...

Descripción completa

Detalles Bibliográficos
Autores principales: Resch, Hemma, Mitsch, Christoph, Pereira, Ivania, Schwarzhans, Florian, Wasserman, Lorenz, Hommer, Anton, Reitner, Andreas, Vass, Clemens
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6585641/
https://www.ncbi.nlm.nih.gov/pubmed/30240137
http://dx.doi.org/10.1111/aos.13804
_version_ 1783428740424925184
author Resch, Hemma
Mitsch, Christoph
Pereira, Ivania
Schwarzhans, Florian
Wasserman, Lorenz
Hommer, Anton
Reitner, Andreas
Vass, Clemens
author_facet Resch, Hemma
Mitsch, Christoph
Pereira, Ivania
Schwarzhans, Florian
Wasserman, Lorenz
Hommer, Anton
Reitner, Andreas
Vass, Clemens
author_sort Resch, Hemma
collection PubMed
description PURPOSE: Optic nerve head (ONH) parameters as well as circumpapillary retinal nerve fibre layer (RNFL) thickness values measured with two different spectral domain optical coherence tomography (SD‐OCT) machines (Spectralis(®) and Cirrus(®) OCT) have been compared between two patient groups, primary open‐angle glaucoma (POAG), nonarteritic anterior ischaemic optic neuropathy (NAION) and healthy controls. A comparison of the performance of the two OCT machines was made. METHODS: Twenty healthy controls, 20 POAG and 20 NAION patients with comparable visual field defects were included. Comparison between groups was made using anova and post hoc t‐tests. To evaluate the diagnostic power of OCT to differentiate POAG from NAION, a stepwise linear regression analysis of the rim‐RNFL correlation with adjusting covariates (optic disc area and age) was performed. Based on the regression formula, the area under the receiver operator characteristic (AUROC) was calculated. RESULTS: Both glaucoma and NAION patients showed significantly smaller global RNFL thickness values compared to healthy subjects in t‐tests (p < 0.001), while only patients with glaucoma showed significantly smaller global ONH parameters for both devices compared to healthy subjects (p < 0.001). Correlation between global ONH parameters was highly statistically significant (r = 0.93), whereas in t‐test a statistically significant difference between the two machines was detected (p < 0.001). Area under the receiver operator characteristic revealed a similarly good discrimination between glaucoma and NAION for Spectralis(®) (0.980) and Cirrus(®) OCT (0.945). CONCLUSION: NAION patients have similar RNFL thickness values as do glaucomatous eyes, whereas ONH parameters in NAION eyes were similar to those seen in healthy controls. This difference might help discriminating between these two different disease conditions in a chronic disease stadium, and in this regard, none of the two OCT machines performed better.
format Online
Article
Text
id pubmed-6585641
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-65856412019-06-27 Optic nerve head morphology in primary open‐angle glaucoma and nonarteritic anterior ischaemic optic neuropathy measured with spectral domain optical coherence tomography Resch, Hemma Mitsch, Christoph Pereira, Ivania Schwarzhans, Florian Wasserman, Lorenz Hommer, Anton Reitner, Andreas Vass, Clemens Acta Ophthalmol Original Articles PURPOSE: Optic nerve head (ONH) parameters as well as circumpapillary retinal nerve fibre layer (RNFL) thickness values measured with two different spectral domain optical coherence tomography (SD‐OCT) machines (Spectralis(®) and Cirrus(®) OCT) have been compared between two patient groups, primary open‐angle glaucoma (POAG), nonarteritic anterior ischaemic optic neuropathy (NAION) and healthy controls. A comparison of the performance of the two OCT machines was made. METHODS: Twenty healthy controls, 20 POAG and 20 NAION patients with comparable visual field defects were included. Comparison between groups was made using anova and post hoc t‐tests. To evaluate the diagnostic power of OCT to differentiate POAG from NAION, a stepwise linear regression analysis of the rim‐RNFL correlation with adjusting covariates (optic disc area and age) was performed. Based on the regression formula, the area under the receiver operator characteristic (AUROC) was calculated. RESULTS: Both glaucoma and NAION patients showed significantly smaller global RNFL thickness values compared to healthy subjects in t‐tests (p < 0.001), while only patients with glaucoma showed significantly smaller global ONH parameters for both devices compared to healthy subjects (p < 0.001). Correlation between global ONH parameters was highly statistically significant (r = 0.93), whereas in t‐test a statistically significant difference between the two machines was detected (p < 0.001). Area under the receiver operator characteristic revealed a similarly good discrimination between glaucoma and NAION for Spectralis(®) (0.980) and Cirrus(®) OCT (0.945). CONCLUSION: NAION patients have similar RNFL thickness values as do glaucomatous eyes, whereas ONH parameters in NAION eyes were similar to those seen in healthy controls. This difference might help discriminating between these two different disease conditions in a chronic disease stadium, and in this regard, none of the two OCT machines performed better. John Wiley and Sons Inc. 2018-09-21 2018-12 /pmc/articles/PMC6585641/ /pubmed/30240137 http://dx.doi.org/10.1111/aos.13804 Text en © 2018 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Resch, Hemma
Mitsch, Christoph
Pereira, Ivania
Schwarzhans, Florian
Wasserman, Lorenz
Hommer, Anton
Reitner, Andreas
Vass, Clemens
Optic nerve head morphology in primary open‐angle glaucoma and nonarteritic anterior ischaemic optic neuropathy measured with spectral domain optical coherence tomography
title Optic nerve head morphology in primary open‐angle glaucoma and nonarteritic anterior ischaemic optic neuropathy measured with spectral domain optical coherence tomography
title_full Optic nerve head morphology in primary open‐angle glaucoma and nonarteritic anterior ischaemic optic neuropathy measured with spectral domain optical coherence tomography
title_fullStr Optic nerve head morphology in primary open‐angle glaucoma and nonarteritic anterior ischaemic optic neuropathy measured with spectral domain optical coherence tomography
title_full_unstemmed Optic nerve head morphology in primary open‐angle glaucoma and nonarteritic anterior ischaemic optic neuropathy measured with spectral domain optical coherence tomography
title_short Optic nerve head morphology in primary open‐angle glaucoma and nonarteritic anterior ischaemic optic neuropathy measured with spectral domain optical coherence tomography
title_sort optic nerve head morphology in primary open‐angle glaucoma and nonarteritic anterior ischaemic optic neuropathy measured with spectral domain optical coherence tomography
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6585641/
https://www.ncbi.nlm.nih.gov/pubmed/30240137
http://dx.doi.org/10.1111/aos.13804
work_keys_str_mv AT reschhemma opticnerveheadmorphologyinprimaryopenangleglaucomaandnonarteriticanteriorischaemicopticneuropathymeasuredwithspectraldomainopticalcoherencetomography
AT mitschchristoph opticnerveheadmorphologyinprimaryopenangleglaucomaandnonarteriticanteriorischaemicopticneuropathymeasuredwithspectraldomainopticalcoherencetomography
AT pereiraivania opticnerveheadmorphologyinprimaryopenangleglaucomaandnonarteriticanteriorischaemicopticneuropathymeasuredwithspectraldomainopticalcoherencetomography
AT schwarzhansflorian opticnerveheadmorphologyinprimaryopenangleglaucomaandnonarteriticanteriorischaemicopticneuropathymeasuredwithspectraldomainopticalcoherencetomography
AT wassermanlorenz opticnerveheadmorphologyinprimaryopenangleglaucomaandnonarteriticanteriorischaemicopticneuropathymeasuredwithspectraldomainopticalcoherencetomography
AT hommeranton opticnerveheadmorphologyinprimaryopenangleglaucomaandnonarteriticanteriorischaemicopticneuropathymeasuredwithspectraldomainopticalcoherencetomography
AT reitnerandreas opticnerveheadmorphologyinprimaryopenangleglaucomaandnonarteriticanteriorischaemicopticneuropathymeasuredwithspectraldomainopticalcoherencetomography
AT vassclemens opticnerveheadmorphologyinprimaryopenangleglaucomaandnonarteriticanteriorischaemicopticneuropathymeasuredwithspectraldomainopticalcoherencetomography