High intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: Safety and efficacy study of a dual tissue effect based non‐invasive abdominal body shaping

OBJECTIVES: This study introduces an initial evaluation of a novel High‐Intensity Focused Electromagnetic (HIFEM) technology. The primary goal is to quantify any effects the treatments may have on abdominal tissues, as well as to establish hypotheses for future research of this technology. METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Kinney, Brian M., Lozanova, Paula
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6585690/
https://www.ncbi.nlm.nih.gov/pubmed/30302767
http://dx.doi.org/10.1002/lsm.23024
_version_ 1783428751326969856
author Kinney, Brian M.
Lozanova, Paula
author_facet Kinney, Brian M.
Lozanova, Paula
author_sort Kinney, Brian M.
collection PubMed
description OBJECTIVES: This study introduces an initial evaluation of a novel High‐Intensity Focused Electromagnetic (HIFEM) technology. The primary goal is to quantify any effects the treatments may have on abdominal tissues, as well as to establish hypotheses for future research of this technology. METHODS: Twenty‐two patients received four abdominal treatments using the EMSCULPT device (BTL Industries Inc., Boston, MA). Anthropometric evaluations were recorded and digital photographs were taken at baseline, at 2 months, and at 6 months post‐treatments. The MRI without contrast determined by vertertebras T12 and S1 (FIESTA and FSPRG sequences) was used to measure dimensions in coronal cross‐sectional images of abdominal muscle and fatty tissues, in order to assess any anatomical changes induced by the application. RESULTS: Analysis of the same MRI slices verified by tissue artefacts showed a statistically significant (all P < 0.0001) average 18.6% reduction of adipose tissue thickness, 15.4% increase in rectus abdominis muscle thickness, and 10.4% reduction in rectus abdominus separation (diastasis recti) as measured from the medial border of the muscle 2 months post‐treatment. More significant improvements were observed in patients with BMI 18.5–24.9 (classified as “normal”). MRI data from 6‐month follow‐up suggest the changes can be preserved in longer term. Tape measurements showed on average 3.8 cm subumbilical circumference reduction. The weight of the subjects did not change significantly (average −0.5 lb; P > 0.05). No adverse events were reported. CONCLUSIONS: MRI, considered as a highly precise diagnostic method, revealed simultaneous muscle growth, fat reduction and reduced abdominal separation at 2 months and at 6 months post treatments, unrelated with dieting. Further research should investigate the exact physiological processes which stand behind the tissue changes observed in this study. Lasers Surg. Med. 51:40–46, 2019. © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.
format Online
Article
Text
id pubmed-6585690
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-65856902019-06-27 High intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: Safety and efficacy study of a dual tissue effect based non‐invasive abdominal body shaping Kinney, Brian M. Lozanova, Paula Lasers Surg Med Dermatology / Plastic Surgery OBJECTIVES: This study introduces an initial evaluation of a novel High‐Intensity Focused Electromagnetic (HIFEM) technology. The primary goal is to quantify any effects the treatments may have on abdominal tissues, as well as to establish hypotheses for future research of this technology. METHODS: Twenty‐two patients received four abdominal treatments using the EMSCULPT device (BTL Industries Inc., Boston, MA). Anthropometric evaluations were recorded and digital photographs were taken at baseline, at 2 months, and at 6 months post‐treatments. The MRI without contrast determined by vertertebras T12 and S1 (FIESTA and FSPRG sequences) was used to measure dimensions in coronal cross‐sectional images of abdominal muscle and fatty tissues, in order to assess any anatomical changes induced by the application. RESULTS: Analysis of the same MRI slices verified by tissue artefacts showed a statistically significant (all P < 0.0001) average 18.6% reduction of adipose tissue thickness, 15.4% increase in rectus abdominis muscle thickness, and 10.4% reduction in rectus abdominus separation (diastasis recti) as measured from the medial border of the muscle 2 months post‐treatment. More significant improvements were observed in patients with BMI 18.5–24.9 (classified as “normal”). MRI data from 6‐month follow‐up suggest the changes can be preserved in longer term. Tape measurements showed on average 3.8 cm subumbilical circumference reduction. The weight of the subjects did not change significantly (average −0.5 lb; P > 0.05). No adverse events were reported. CONCLUSIONS: MRI, considered as a highly precise diagnostic method, revealed simultaneous muscle growth, fat reduction and reduced abdominal separation at 2 months and at 6 months post treatments, unrelated with dieting. Further research should investigate the exact physiological processes which stand behind the tissue changes observed in this study. Lasers Surg. Med. 51:40–46, 2019. © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. John Wiley and Sons Inc. 2018-10-10 2019-01 /pmc/articles/PMC6585690/ /pubmed/30302767 http://dx.doi.org/10.1002/lsm.23024 Text en © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Dermatology / Plastic Surgery
Kinney, Brian M.
Lozanova, Paula
High intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: Safety and efficacy study of a dual tissue effect based non‐invasive abdominal body shaping
title High intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: Safety and efficacy study of a dual tissue effect based non‐invasive abdominal body shaping
title_full High intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: Safety and efficacy study of a dual tissue effect based non‐invasive abdominal body shaping
title_fullStr High intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: Safety and efficacy study of a dual tissue effect based non‐invasive abdominal body shaping
title_full_unstemmed High intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: Safety and efficacy study of a dual tissue effect based non‐invasive abdominal body shaping
title_short High intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: Safety and efficacy study of a dual tissue effect based non‐invasive abdominal body shaping
title_sort high intensity focused electromagnetic therapy evaluated by magnetic resonance imaging: safety and efficacy study of a dual tissue effect based non‐invasive abdominal body shaping
topic Dermatology / Plastic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6585690/
https://www.ncbi.nlm.nih.gov/pubmed/30302767
http://dx.doi.org/10.1002/lsm.23024
work_keys_str_mv AT kinneybrianm highintensityfocusedelectromagnetictherapyevaluatedbymagneticresonanceimagingsafetyandefficacystudyofadualtissueeffectbasednoninvasiveabdominalbodyshaping
AT lozanovapaula highintensityfocusedelectromagnetictherapyevaluatedbymagneticresonanceimagingsafetyandefficacystudyofadualtissueeffectbasednoninvasiveabdominalbodyshaping