Cargando…
Does the type of electrode affect the electromyoneurographic parameters in rats?
PURPOSE: To evaluate if the type of electrode (needle vs. surface) affects the electromyoneurography parameters in rats. METHODS: Twenty male rats were anesthetized, then compound muscle action potential were recorded using a Neuropack S1 MEB- 9400(©). All animals were submitted to two electroneurom...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em
Cirurgia
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6585890/ https://www.ncbi.nlm.nih.gov/pubmed/30892390 http://dx.doi.org/10.1590/s0102-865020190030000004 |
_version_ | 1783428797417127936 |
---|---|
author | Somensi, Danusa Neves Teixeira, Renan Kleber Costa Feijó, Daniel Haber Loureiro, Karine Drumond Valente, André Lopes de Carvalho, Luan Teles Ferreira Calvo, Faustino Chaves dos Santos, Deivid Ramos de Barros, Rui Sergio Monteiro |
author_facet | Somensi, Danusa Neves Teixeira, Renan Kleber Costa Feijó, Daniel Haber Loureiro, Karine Drumond Valente, André Lopes de Carvalho, Luan Teles Ferreira Calvo, Faustino Chaves dos Santos, Deivid Ramos de Barros, Rui Sergio Monteiro |
author_sort | Somensi, Danusa Neves |
collection | PubMed |
description | PURPOSE: To evaluate if the type of electrode (needle vs. surface) affects the electromyoneurography parameters in rats. METHODS: Twenty male rats were anesthetized, then compound muscle action potential were recorded using a Neuropack S1 MEB- 9400(©). All animals were submitted to two electroneuromyography analysis: first with surface electrode and then by needle electrode. We evaluated the latency, amplitude, duration and area of the negative peak of the gastrocnemius and cranial tibial muscles. RESULTS: There were no significant differences between the groups in the mean of duration, latency, amplitude or area of the negative peak in gastrocnemius and cranial tibial muscles. CONCLUSION: The type of electrode does not affect the electroneuromyography parameters. |
format | Online Article Text |
id | pubmed-6585890 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Sociedade Brasileira para o Desenvolvimento da Pesquisa em
Cirurgia |
record_format | MEDLINE/PubMed |
spelling | pubmed-65858902019-07-02 Does the type of electrode affect the electromyoneurographic parameters in rats? Somensi, Danusa Neves Teixeira, Renan Kleber Costa Feijó, Daniel Haber Loureiro, Karine Drumond Valente, André Lopes de Carvalho, Luan Teles Ferreira Calvo, Faustino Chaves dos Santos, Deivid Ramos de Barros, Rui Sergio Monteiro Acta Cir Bras ORIGINAL ARTICLE PURPOSE: To evaluate if the type of electrode (needle vs. surface) affects the electromyoneurography parameters in rats. METHODS: Twenty male rats were anesthetized, then compound muscle action potential were recorded using a Neuropack S1 MEB- 9400(©). All animals were submitted to two electroneuromyography analysis: first with surface electrode and then by needle electrode. We evaluated the latency, amplitude, duration and area of the negative peak of the gastrocnemius and cranial tibial muscles. RESULTS: There were no significant differences between the groups in the mean of duration, latency, amplitude or area of the negative peak in gastrocnemius and cranial tibial muscles. CONCLUSION: The type of electrode does not affect the electroneuromyography parameters. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia 2019-03-18 /pmc/articles/PMC6585890/ /pubmed/30892390 http://dx.doi.org/10.1590/s0102-865020190030000004 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License |
spellingShingle | ORIGINAL ARTICLE Somensi, Danusa Neves Teixeira, Renan Kleber Costa Feijó, Daniel Haber Loureiro, Karine Drumond Valente, André Lopes de Carvalho, Luan Teles Ferreira Calvo, Faustino Chaves dos Santos, Deivid Ramos de Barros, Rui Sergio Monteiro Does the type of electrode affect the electromyoneurographic parameters in rats? |
title | Does the type of electrode affect the electromyoneurographic
parameters in rats?
|
title_full | Does the type of electrode affect the electromyoneurographic
parameters in rats?
|
title_fullStr | Does the type of electrode affect the electromyoneurographic
parameters in rats?
|
title_full_unstemmed | Does the type of electrode affect the electromyoneurographic
parameters in rats?
|
title_short | Does the type of electrode affect the electromyoneurographic
parameters in rats?
|
title_sort | does the type of electrode affect the electromyoneurographic
parameters in rats? |
topic | ORIGINAL ARTICLE |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6585890/ https://www.ncbi.nlm.nih.gov/pubmed/30892390 http://dx.doi.org/10.1590/s0102-865020190030000004 |
work_keys_str_mv | AT somensidanusaneves doesthetypeofelectrodeaffecttheelectromyoneurographicparametersinrats AT teixeirarenanklebercosta doesthetypeofelectrodeaffecttheelectromyoneurographicparametersinrats AT feijodanielhaber doesthetypeofelectrodeaffecttheelectromyoneurographicparametersinrats AT loureirokarinedrumond doesthetypeofelectrodeaffecttheelectromyoneurographicparametersinrats AT valenteandrelopes doesthetypeofelectrodeaffecttheelectromyoneurographicparametersinrats AT decarvalholuantelesferreira doesthetypeofelectrodeaffecttheelectromyoneurographicparametersinrats AT calvofaustinochaves doesthetypeofelectrodeaffecttheelectromyoneurographicparametersinrats AT dossantosdeividramos doesthetypeofelectrodeaffecttheelectromyoneurographicparametersinrats AT debarrosruisergiomonteiro doesthetypeofelectrodeaffecttheelectromyoneurographicparametersinrats |